Back to Authors

Weiss, Raul

https://orcid.org/0000-0003-1489-4028

Mayo Clinic

The Ohio State University Wexner Medical Center

Citations 8

Process mapping strategies to prevent subcutaneous implantable cardioverter‐defibrillator infections
Weiss, Raul , Mark, George E., Lambiase, Pier D. , Miller, Marc A. , McClernon, Timothy R., Knight, Bradley P. , El-Chami, Mikhael F , Miller, Marc A , Lambiase, Pier D , Knight, Bradley P , Weiss, Raul , El‐Chami, Mikhael F. , Biffi, Mauro , Probst, Vincent , Hansen, Linda K. , Baddour, Larry M.

Journal of Cardiovascular Electrophysiology | June 4, 2022 | Volume: 33 | Issue: 7 | Pages: 1628-1635

10.1111/jce.15566 Get It

AbstractBackgroundInfection remains a major complication of cardiac implantable electronic devices and can lead to significant morbidity and mortality. Implantable devices that avoid transvenous leads, such as the subcutaneous implantable cardioverter‐defibrillator (S‐ICD), can reduce the risk of serious infection‐related complications, such as bloodstream infection and infective endocarditis. While the 2017 AHA/ACC/HRS guidelines include recommendations for S‐ICD use for patients at high risk of infection, currently, there are no clinical trial data that address best practices for the prevention of S‐ICD infections. Therefore, an expert panel was convened to develop a consensus on these topics.MethodsAn expert process mapping methodology was used to achieve consensus on the appropriate steps to minimize or prevent S‐ICD infections. Two face‐to‐face meetings of high‐volume S‐ICD implanters and an infectious diseases specialist, with expertise in cardiovascular implantable electronic device infections, were conducted to develop consensus on useful strategies pre‐, peri‐, and postimplant to reduce S‐ICD infection risk.ResultsExpert panel consensus on recommended steps for patient preparation, S‐ICD implantation, and postoperative management was developed to provide guidance in individual patient management.ConclusionAchieving expert panel consensus by process mapping methodology for S‐ICD infection prevention was attainable, and the results should be helpful to clinicians in adopting interventions to minimize risks of S‐ICD infection.
Device‐related infection associated with increased mortality risk in de novo transvenous implantable cardioverter‐defibrillator medicare patients
Liu, Yiyan , Griffiths, Robert I. , Knight, Bradley P. , Weiss, Raul , Mark, George E., Lambiase, Pier D. , Miller, Marc A. , Jacobsen, Caroline M., El-Chami, Mikhael F , Weiss, Raul , Miller, Marc A , Lambiase, Pier D , Knight, Bradley P , El‐Chami, Mikhael F. , Biffi, Mauro , Probst, Vincent , Baddour, Larry M.

Journal of Cardiovascular Electrophysiology | January 23, 2022 | Volume: 33 | Issue: 4 | Pages: 725-730

10.1111/jce.15385 Get It

AbstractIntroductionTransvenous implantable cardioverter‐defibrillators (TV‐ICD) infection is a serious complication that frequently requires complete device removal for attempted cure, which can be associated with patient morbidity and mortality. The objective of this study is to assess mortality risk associated with TV‐ICD infection in a large Medicare population with de novo TV‐ICD implants.MethodsA survival analysis was conducted using 100% fee‐for‐service Medicare facility‐level claims data to identify patients who underwent de novo TV‐ICD implantation between 7/2016 and 1/2018. TV‐ICD infection within 2 years of implantation was identified using International Classification of Disease, 10th Edition and current procedural terminology codes. Baseline patient risk factors associated with mortality were identified using the Charlson Comorbidity Index categories. Infection was treated as a time‐dependent variable in a multivariate Cox proportional hazards model to account for immortal time bias.ResultsAmong 26,742 Medicare patients with de novo TV‐ICD, 518 (1.9%) had a device‐related infection. The overall number of decedents was 4721 (17.7%) over 2 years, with 4555 (17%) in the noninfection group and 166 (32%) in the infection group. After adjusting for baseline patient demographic characteristics and various comorbidities, the presence of TV‐ICD infection was associated with an increase of 2.4 (95% CI: 2.08–2.85) times in the mortality hazard ratio.ConclusionThe rate of TV‐ICD infection and associated mortality in a large, real‐world Medicare population is noteworthy. The positive association between device‐related infection and risk of mortality further highlights the need to reduce infections
Process Mapping Strategies to Prevent Subcutaneous Implantable Cardioverter-Defibrillator Infection
Weiss, Raul , Mark, G. J., Miller, Marc A. , McClernon, Timothy R., Weiss, Raul , Mark, George, El‐Chami, Mikhael F. , Biffi, Mauro , Probst, Vincent , Lambiase, Pier D. , Hansen, Linda, Knight, Bradley P. , Baddour, Larry M.

No container title available | January 2, 2022 | Volume: No volume available | Issue: No issue available | Pages: No page available

10.22541/au.164118494.47265902/v1 Get It

Background: Infection remains a major complication of cardiac implantable electronic devices (CIEDs) and can lead to significant morbidity and mortality. Extrathoracic devices that avoid epicardial or transvenous leads, such as the subcutaneous implantable cardioverter-defibrillator (S-ICD), can reduce the risk of serious infection-related complications, such as bloodstream infection and infective endocarditis. While the 2017 AHA/ACC/HRS guidelines include recommendations for S-ICD use for patients at high risk of infection, currently, there are no clinical trial data that address best practices for the prevention of S-ICD infections. Therefore, an expert panel was convened to develop consensus on these topics. Methods: An expert process mapping methodology was used to achieve consensus on the appropriate steps to minimize or prevent S-ICD infections. Two face-to-face meetings of high-volume S-ICD implanters and an infectious diseases specialist, with expertise on cardiovascular implantable electronic device infections, were conducted to develop consensus on useful strategies pre-, peri-, and post-implant to reduce S-ICD infection risk. Results: Expert panel consensus of recommended steps for patient preparation, S-ICD implantation, and post-operative management were developed to provide guidance in individual patient management. Conclusion: Achieving expert panel consensus by process mapping methodology for S-ICD infection prevention was attainable, and the results should be helpful to clinicians in adopting interventions to minimize risks of S-ICD infection.
Abstract 15562: Incidence and Risk Factors of Device-related Infection in De Novo Transvenous Implantable Cardiac Defibrillator Medicare Patients
Jacobsen, Caroline M., Wold, Nicholas , Amorosi, Stacey L., Stivland, Timothy M. , Mark, George E., Lambiase, Pier D. , Miller, Marc A. , Lambiase, Pier D , El‐Chami, Mikhael F. , Griffiths, Robert I, Hansen, Linda K. , Knight, Bradley P. , Weiss, Raul , Biffi, Mauro , Probst, Vincent , Baddour, Larry M.

Circulation | May 10, 2021 | Volume: 142 | Issue: Suppl_3 | Pages: No page available

10.1161/circ.142.suppl_3.15562 Get It

Introduction: Practice guidelines recommend use of subcutaneous implantable cardioverter-defibrillators (ICD) in patients (pts) at risk of sudden cardiac death and high risk for infection. This has prompted a need to better identify pts at high risk of infection to assist in de novo device selection. The objective of this study is to estimate infection incidence in de novo transvenous (TV) ICD implants and assess risk factors associated with infection in a large Medicare population. Methods: A retrospective cohort study was conducted using 100% Medicare administrative and claims data to identify pts who underwent de novo TV-ICD implantation between 7/2016 and 1/2018. Device-related infection within 2 years of implantation was identified using ICD-10 diagnosis and procedure codes. Baseline pt factors associated with infection were identified by univariable logistic regression analysis of all variables of interest, including factors in Charlson and Elixhauser comorbidity indices, followed by stepwise selection criteria with a p≤0.25 for inclusion in a multivariable model and a backwards, stepwise elimination process with p≤0.1 to remain in the model. A time-to-event analysis was also conducted. Results: Among 26,742 pts with de novo TV-ICD, 519 (1.9%) had a device-related infection over 2 years. The mean pt age with and without infection was 68 and 71 years, respectively. While more than half (54%) of infections occurred within 90 days post implant, infections continued to be diagnosed with 16% of infections occurring between years 1 and 2. Multivariable analysis revealed several significant predictors of infection (Figure) including age <70 years, end stage renal disease with chronic dialysis and diabetes with complications. Conclusion: The rate of de novo TV-ICD infection in a large real-world Medicare population is clinically significant. The factors associated with increased infection risk identified here can be used to help determine device selection.
Diagnosis and management of subcutaneous implantable cardioverter‐defibrillator infections based on process mapping
Baddour, Larry M. , Weiss, Raul , Mark, George E., Biffi, Mauro , Probst, Vincent , Lambiase, Pier D. , Miller, Marc A. , McClernon, Timothy R., Hansen, Linda K. , Knight, Bradley P. , El-Chami, Mikhael F , Biffi, Mauro , Probst, Vincent , Lambiase, Pier D , Hansen, Linda K , Knight, Bradley P , Baddour, Larry , Weiss, Raul , El‐Chami, Mikhael F.

Pacing and Clinical Electrophysiology | April 8, 2020 | Volume: 43 | Issue: 9 | Pages: 958-965

10.1111/pace.13902 Get It

AbstractBackgroundInfection is a well‐recognized complication of cardiovascular implantable electronic device (CIED) implantation, including the more recently available subcutaneous implantable cardioverter‐defibrillator (S‐ICD). Although the AHA/ACC/HRS guidelines include recommendations for S‐ICD use, currently there are no clinical trial data that address the diagnosis and management of S‐ICD infections. Therefore, an expert panel was convened to develop consensus on these topics.MethodsA process mapping methodology was used to achieve a primary goal – the development of consensus on the diagnosis and management of S‐ICD infections. Two face‐to‐face meetings of panel experts were conducted to recommend useful information to clinicians in individual patient management of S‐ICD infections.ResultsPanel consensus of a stepwise approach in the diagnosis and management was developed to provide guidance in individual patient management.ConclusionAchieving expert panel consensus by process mapping methodology in S‐ICD infection diagnosis and management was attainable, and the results should be helpful in individual patient management.
RIsk Stratification prior to lead Extraction and impact on major intraprocedural complications (RISE protocol)
Afzal, Muhammad R. , Daoud, Emile G. , Matre, Nancy, Burnside, Melissa , Gilliam, Courtney A. , Pinkhas, Daniel, Tyler, Jaret, Kalbfleisch, Steven S., Turner, Katja , Love, Charles J. , Augostini, Ralph , Shoben, Abigail B. , Okabe, Toshimasa , Houmsse, Mahmoud , Kalbfleisch, Steven Jack , Crestanello, Juan A. , Weiss, Raul , Hummel, John D.

Journal of Cardiovascular Electrophysiology | September 10, 2019 | Volume: 30 | Issue: 11 | Pages: 2453-2459

10.1111/jce.14151 Get It

AbstractBackgroundAn internal risk stratification algorithm was developed to decrease the risk of major adverse cardiac events (MACEs) during lead extractions (LEs).ObjectiveTo report upon the impact of a risk stratification algorithm (RISE [RIsk Stratification prior to lead Extraction] protocol) on outcomes of LEs in a high‐volume center.MethodsA retrospective review of a prospectively maintained LEs database was performed to identify features associated with MACEs. On the basis of the retrospective data, the RISE protocol differentiated LEs procedures into “High” and “Low” risk for occurrence of MACEs. High‐risk LEs included dual‐coil defibrillator lead (≥3 years), pacemaker and single‐coil lead (≥5 years), and any StarFix coronary sinus lead. During the prospective evaluation of the RISE protocol, “High‐risk” LEs were performed in an operating room (OR) or hybrid laboratory with the cardiac anesthesiologist, OR nursing team, perfusionist in the room, and a cardiac surgeon on the premises. “Low‐risk” LEs were performed in the electrophysiology (EP) laboratory with anesthesia provided by EP nursing team. The preintervention (pre‐RISE) and postintervention (post‐RISE) group spanned 19 and 40 months and consisted of 449 (632 leads) and 751 patients (1055 leads), respectively. The primary outcome of MACEs in the two groups was compared.ResultsProtocol compliance was 100%. The primary outcome of MACEs occurred in 15 patients (3.34%) before and 12 (1.6%) after implementation of the RISE protocol (P = .04).ConclusionRISE identified a low‐risk group where minimal resources are needed and allowed for rapid intervention in the high‐risk group that reduced the consequences of MACEs.
Type 8 long QT syndrome: pathogenic variants in CACNA1C-encoded Cav1.2 cluster in STAC protein binding site
Mellor, Greg , Panwar, Pankaj, Lee, Andrea K, Hathaway, Julie , Bartels, Kirsten , Balaji, Seshadri , Roberts, Jason D. , Simpson, Chris S., Boczek, Nicole J. , Tester, David J. , Radbill, Andrew E. , Mok, Ngai‐Shing, Hamilton, Robert M. , Kaufman, Elizabeth S. , Eugenio, Paul, January, Craig T., McDaniel, George, Leather, Richard, Falik, Shelley, Behr, Elijah R. , Wilde, Arthur A.M. , Sanatani, Shubhayan , Ackerman, Michael J. , Petegem, Filip Van , Laksman, Zachary , Behr, Elijah Raphael , Sanatani, Shubhayan , Hamilton, Robert , Steinberg, Christian , Christian, Susan , Weiss, Raul , Erickson, Christopher, Krahn, Andrew D.

EP Europace | July 24, 2019 | Volume: 21 | Issue: 11 | Pages: 1725-1732

10.1093/europace/euz215 Get It

Abstract Aims Pathogenic gain-of-function variants in CACAN1C cause type-8 long QT syndrome (LQT8). We sought to describe the electrocardiographic features in LQT8 and utilize molecular modelling to gain mechanistic insights into its genetic culprits. Methods and results Rare variants in CACNA1C were identified from genetic testing laboratories. Treating physicians provided clinical information. Variant pathogenicity was independently assessed according to recent guidelines. Pathogenic (P) and likely pathogenic (LP) variants were mapped onto a 3D modelled structure of the Cav1.2 protein. Nine P/LP variants, identified in 23 patients from 19 families with non-syndromic LQTS were identified. Six variants, found in 79% of families, clustered to a 4-residue section in the cytosolic II–III loop region which forms a region capable of binding STAC SH3 domains. Therefore, variants may affect binding of SH3-domain containing proteins. Arrhythmic events occurred in similar proportions of patients with II–III loop variants and with other P/LP variants (53% vs. 48%, P = 0.41) despite shorter QTc intervals (477 ± 31 ms vs. 515 ± 37 ms, P = 0.03). A history of sudden death was reported only in families with II–III loop variants (60% vs. 0%, P = 0.03). The predominant T-wave morphology was a late peaking T wave with a steep descending limb. Exercise testing demonstrated QTc prolongation on standing and at 4 min recovery after exercise. Conclusion The majority of P/LP variants in patients with CACNA1C-mediated LQT8 cluster in an SH3-binding domain of the cytosolic II–III loop. This represents a ‘mutation hotspot’ in LQT8. A late-peaking T wave with a steep descending limb and QT prolongation on exercise are commonly seen.
Mutation in Glycerol-3-Phosphate Dehydrogenase 1–Like Gene ( GPD1-L ) Decreases Cardiac Na + Current and Causes Inherited Arrhythmias
London, Barry , Michalec, Michael, Mehdi, Haider , Zhu, Xiaodong , Kerchner, Laurie J. , Sanyal, Shamarendra, Viswanathan, Prakash C., Pfahnl, Arnold , Shang, Lijuan L., Madhusudanan, Mohan, Baty, Catherine J. , Lagana, Stephen M. , Gutmann, Rebecca, Ackerman, Michael J. , McNamara, Dennis M. , Dudley, Samuel C. , Aleong, Ryan G. , Weiss, Raul , London, Barry

Circulation | October 29, 2007 | Volume: 116 | Issue: 20 | Pages: 2260-2268

10.1161/circulationaha.107.703330 Get It

Background— Brugada syndrome is a rare, autosomal-dominant, male-predominant form of idiopathic ventricular fibrillation characterized by a right bundle-branch block and ST elevation in the right precordial leads of the surface ECG. Mutations in the cardiac Na + channel SCN5A on chromosome 3p21 cause ≈20% of the cases of Brugada syndrome; most mutations decrease inward Na + current, some by preventing trafficking of the channels to the surface membrane. We previously used positional cloning to identify a new locus on chromosome 3p24 in a large family with Brugada syndrome and excluded SCN5A as a candidate gene. Methods and Results— We used direct sequencing to identify a mutation (A280V) in a conserved amino acid of the glycerol-3-phosphate dehydrogenase 1–like ( GPD1-L ) gene. The mutation was present in all affected individuals and absent in >500 control subjects. GPD1-L RNA and protein are abundant in the heart. Compared with wild-type GPD1-L, coexpression of A280V GPD1-L with SCN5A in HEK cells reduced inward Na + currents by ≈50% ( P <0.005). Wild-type GPD1-L localized near the cell surface to a greater extent than A280V GPD1-L. Coexpression of A280V GPD1-L with SCN5A reduced SCN5A cell surface expression by 31±5% ( P =0.01). Conclusions— GPD1-L is a novel gene that may affect trafficking of the cardiac Na + channel to the cell surface. A GPD1-L mutation decreases SCN5A surface membrane expression, reduces inward Na + current, and causes Brugada syndrome.