Abstract 12087: Device-Related Infection Associated With Increased Mortality Risk in
de novo
Transvenous Implantable Cardioverter-Defibrillator Medicare Patients
Introduction: Device-related infection is estimated to occur in 1.9% of the Medicare patients with de novo transvenous (TV) implantable cardioverter-defibrillators (ICD) within 2 years post-implant. TV-ICD infection is a serious complication that frequently requires complete device removal for attempted cure, which can be associated with patient morbidity and mortality. The objective of this study is to expand on limited published data and assess mortality risk associated with TV-ICD infection in a large Medicare population with de novo TV-ICD implants. Methods: A survival analysis was conducted using 100% fee-for-service Medicare facility-level claims data to identify patients who underwent de novo TV-ICD implantation between 7/2016 and 1/2018. TV-ICD infection within 2 years of implantation was identified using ICD-10 and CPT codes. Baseline patient risk factors associated with mortality were identified using the Charlson Comorbidity Index categories. Infection was treated as a time-dependent variable in a multivariate Cox proportional hazards model to account for immortal time bias. Results: Among 26,742 Medicare patients with de novo TV-ICD, 518 (1.9%) had a device-related infection. The overall number of decedents was 4,721 (17.7%) over 2 years, with 4,555 (17%) in the non-infection group and 166 (32%) in the infection group. After adjusting for baseline patient demographic characteristics and various comorbidities, the presence of TV-ICD infection was associated with an increase of 2.4 [95% CI: 2.08-2.85] times in the mortality hazard ratio (see attached Figure). Most of the baseline patient risk factors were also associated with higher risk of mortality in the Cox model. Conclusion: The rate of de novo TV-ICD infection and associated mortality in a large, real-world Medicare population is noteworthy. The positive association between device-related infection and risk of mortality further highlights the need to reduce infections.
Device‐related infection associated with increased mortality risk in de novo transvenous implantable cardioverter‐defibrillator medicare patients
AbstractIntroductionTransvenous implantable cardioverter‐defibrillators (TV‐ICD) infection is a serious complication that frequently requires complete device removal for attempted cure, which can be associated with patient morbidity and mortality. The objective of this study is to assess mortality risk associated with TV‐ICD infection in a large Medicare population with de novo TV‐ICD implants.MethodsA survival analysis was conducted using 100% fee‐for‐service Medicare facility‐level claims data to identify patients who underwent de novo TV‐ICD implantation between 7/2016 and 1/2018. TV‐ICD infection within 2 years of implantation was identified using International Classification of Disease, 10th Edition and current procedural terminology codes. Baseline patient risk factors associated with mortality were identified using the Charlson Comorbidity Index categories. Infection was treated as a time‐dependent variable in a multivariate Cox proportional hazards model to account for immortal time bias.ResultsAmong 26,742 Medicare patients with de novo TV‐ICD, 518 (1.9%) had a device‐related infection. The overall number of decedents was 4721 (17.7%) over 2 years, with 4555 (17%) in the noninfection group and 166 (32%) in the infection group. After adjusting for baseline patient demographic characteristics and various comorbidities, the presence of TV‐ICD infection was associated with an increase of 2.4 (95% CI: 2.08–2.85) times in the mortality hazard ratio.ConclusionThe rate of TV‐ICD infection and associated mortality in a large, real‐world Medicare population is noteworthy. The positive association between device‐related infection and risk of mortality further highlights the need to reduce infections
Abstract 15562: Incidence and Risk Factors of Device-related Infection in
De Novo
Transvenous Implantable Cardiac Defibrillator Medicare Patients
Introduction: Practice guidelines recommend use of subcutaneous implantable cardioverter-defibrillators (ICD) in patients (pts) at risk of sudden cardiac death and high risk for infection. This has prompted a need to better identify pts at high risk of infection to assist in de novo device selection. The objective of this study is to estimate infection incidence in de novo transvenous (TV) ICD implants and assess risk factors associated with infection in a large Medicare population. Methods: A retrospective cohort study was conducted using 100% Medicare administrative and claims data to identify pts who underwent de novo TV-ICD implantation between 7/2016 and 1/2018. Device-related infection within 2 years of implantation was identified using ICD-10 diagnosis and procedure codes. Baseline pt factors associated with infection were identified by univariable logistic regression analysis of all variables of interest, including factors in Charlson and Elixhauser comorbidity indices, followed by stepwise selection criteria with a p≤0.25 for inclusion in a multivariable model and a backwards, stepwise elimination process with p≤0.1 to remain in the model. A time-to-event analysis was also conducted. Results: Among 26,742 pts with de novo TV-ICD, 519 (1.9%) had a device-related infection over 2 years. The mean pt age with and without infection was 68 and 71 years, respectively. While more than half (54%) of infections occurred within 90 days post implant, infections continued to be diagnosed with 16% of infections occurring between years 1 and 2. Multivariable analysis revealed several significant predictors of infection (Figure) including age <70 years, end stage renal disease with chronic dialysis and diabetes with complications. Conclusion: The rate of de novo TV-ICD infection in a large real-world Medicare population is clinically significant. The factors associated with increased infection risk identified here can be used to help determine device selection.