Fagan, Dedra H.

https://orcid.org/0000-0002-1430-4588

Mayo Clinic

Medtronic (United States)

Citations 2

Leadless pacemakers at 5-year follow-up: the Micra transcatheter pacing system post-approval registry
Garweg, Christophe , Clementy, Nicolas, Al-Samadi, Faisal, Iacopino, Saverio , Roberts, Paul R. , Johansen, Jens Brock , Vinolas-Prat, X., Cha, Yong‐Mei , Grubman, Eric , Bordachar, Pierre , Fagan, Dedra H. , Piccini, Jonathan P. , El-Chami, Mikhael F , Garweg, Christophe , Johansen, Jens Brock , Cha, Yong-Mei , Stromberg, Kurt , El‐Chami, Mikhael F. , Clémenty, Nicolas , Martínez‐Sande, José Luis , Tondo, Claudio , Stromberg, Kurt

European Heart Journal | February 9, 2024 | Volume: 45 | Issue: 14 | Pages: 1241-1251

10.1093/eurheartj/ehae101 Get It

Abstract Background and Aims Prior reports have demonstrated a favourable safety and efficacy profile of the Micra leadless pacemaker over mid-term follow-up; however, long-term outcomes in real-world clinical practice remain unknown. Updated performance of the Micra VR leadless pacemaker through five years from the worldwide post-approval registry (PAR) was assessed. Methods All Micra PAR patients undergoing implant attempts were included. Endpoints included system- or procedure-related major complications and system revision rate for any cause through 60 months post-implant. Rates were compared through 36 months post-implant to a reference dataset of 2667 transvenous pacemaker patients using Fine–Gray competing risk models. Results 1809 patients were enrolled between July 2015 and March 2018 and underwent implant attempts from 179 centres in 23 countries with a median follow-up period of 51.1 months (IQR: 21.6–64.2). The major complication rate at 60 months was 4.5% [95% confidence interval (CI): 3.6%–5.5%] and was 4.1% at 36 months, which was significantly lower than the 8.5% rate observed for transvenous systems (HR: .47, 95% CI: .36–.61; P < .001). The all-cause system revision rate at 60 months was 4.9% (95% CI: 3.9%–6.1%). System revisions among Micra patients were mostly for device upgrades (41.2%) or elevated thresholds (30.6%). There were no Micra removals due to infection noted over the duration of follow-up. At 36 months, the system revision rate was significantly lower with Micra vs. transvenous systems (3.2% vs. 6.6%, P < .001). Conclusions Long-term outcomes with the Micra leadless pacemaker continue to demonstrate low rates of major complications and system revisions and an extremely low incidence of infection.
Incidence and outcomes of systemic infections in patients with leadless pacemakers: Data from the Micra IDE study
El‐Chami, Mikhael F. , Soejima, Kyoko , Piccini, Jonathan P. , Reynolds, Dwight, Ritter, Philippe , Okabe, Toshimasa , Friedman, Paul A. , Cha, Yong‐Mei , Stromberg, Kurt , Holbrook, Reece , Fagan, Dedra H. , Roberts, Paul R. , El-Chami, Mikhael F , Stromberg, Kurt

Pacing and Clinical Electrophysiology | June 24, 2019 | Volume: 42 | Issue: 8 | Pages: 1105-1110

10.1111/pace.13752 Get It

AbstractBackgroundThe Micra clinical trials have enrolled more than 2500 patients without any reported device‐related infections that required removal during follow‐up. Leadless pacemakers might be more resistant to bacterial seeding due to smaller surface area and a greater tendency for encapsulation.ObjectiveTo analyze the incidence and outcomes of serious infectious events (SIEs: bacteremia or endocarditis) that developed during follow‐up in patients with history of Micra leadless pacemaker implantation.MethodsSIE and outcomes were characterized based upon adverse event reports. Among 720 patients implanted with Micra in the investigational device exemption trial, we identified 16 patients who had documented 21 SIEs during follow‐up.ResultsAmong patients with SIEs, mean age was 71.9 ± 11.7 years. SIEs occurred at a mean 4.8 ± 4.5 months after implant and patients were followed for 13.1 ± 9.1 months after documentation of SIE. All events were adjudicated as unrelated to the Micra device or procedure. Bacteremia was documented to be related to a gram‐positive organism in 13 events (seven Staphylococcus, three Streptococcus, two Enterococcus, and one uncharacterized gram‐positive bacteria), and gram‐negative organisms in three events. In five events, the type of organism was not characterized (two patients with endocarditis). No persistent cases of bacteremia after antibiotic cessation were seen over the duration of follow‐upConclusionIn this small series of Micra patients who developed SIEs postimplant, the occurrence of bacteremia and/or endocarditis did not appear to lead to persistent bacteremia off antibiotics; most events resolved with antibiotic treatment.