Back to Authors

Beinart, Roy

https://orcid.org/0000-0002-9268-4766

Mayo Clinic

Tel Aviv University

Citations 3

Mitral valve prolapse: arrhythmic risk during pregnancy and postpartum
Sabbag, Avi , Aabel, Eivind W. , Castrini, Anna Isotta , Siontis, Konstantinos C. , Duthoit, Guillaume , Asirvatham, Samuel J. , Sehrawat, Ojasay, Kirkels, Feddo P. , Rav, Moshe , Peichl, Petr , Lim, H. , Martins, Raphaël P. , Font, Jonaz , Truong, Nguyen Ngoc Khoi , Estensen, Mette E , Laredo, Mikael , Duthoit, Guillaume , Kirkels, Feddo P , Beinart, Roy , Peichl, Petr , Sohns, Christian , Haugaa, Kristina , Asirvatham, Samuel J , Martins, Raphael , Aabel, Eivind W , Sabbag, Avi , Nizard, J. , Rosendael, Philippe J. van , Beinart, Roy , Haugaa, Kristina H.

European Heart Journal | May 14, 2024 | Volume: 45 | Issue: 20 | Pages: 1831-1839

10.1093/eurheartj/ehae224 Get It

Abstract Background and Aims Arrhythmic mitral valve prolapse (AMVP) is linked to life-threatening ventricular arrhythmias (VAs), and young women are considered at high risk. Cases of AMVP in women with malignant VA during pregnancy have emerged, but the arrhythmic risk during pregnancy is unknown. The authors aimed to describe features of women with high-risk AMVP who developed malignant VA during the perinatal period and to assess if pregnancy and the postpartum period were associated with a higher risk of malignant VA. Methods This retrospective international multi-centre case series included high-risk women with AMVP who experienced malignant VA and at least one pregnancy. Malignant VA included ventricular fibrillation, sustained ventricular tachycardia, or appropriate shock from an implantable cardioverter defibrillator. The authors compared the incidence of malignant VA in non-pregnant periods and perinatal period; the latter defined as occurring during pregnancy and within 6 months after delivery. Results The authors included 18 women with AMVP from 11 centres. During 7.5 (interquartile range 5.8–16.6) years of follow-up, 37 malignant VAs occurred, of which 18 were pregnancy related occurring in 13 (72%) unique patients. Pregnancy and 6 months after delivery showed increased incidence rate of malignant VA compared to the non-pregnancy period (univariate incidence rate ratio 2.66, 95% confidence interval 1.23–5.76). Conclusions The perinatal period could impose increased risk of malignant VA in women with high-risk AMVP. The data may provide general guidance for pre-conception counselling and for nuanced shared decision-making between patients and clinicians.
Intraoperative defibrillation testing during replacements of implantable cardioverter-defibrillators: The Simpler trial
Nof, Eyal , Regev, Ehud , Rav, Moshe , Kutyifa, Valentina, Merkely, B, Biffi, M, Cha, YM, Ovdat, T, Klempfner, R., Glikson, Michael , Milman, Anat , Beinart, Roy , Kutyifa, Valentina , Biffi, Mauro , Ovdat, T, Glikson, Michael

EP Europace | May 19, 2022 | Volume: 24 | Issue: Supplement_1 | Pages: No page available

10.1093/europace/euac053.461 Get It

Abstract Funding Acknowledgements Type of funding sources: Foundation. Main funding source(s): Maurice Kahn Foundation via the Mayo- Sheba Collaboration Fund. Background The need for intraoperative defibrillation testing (DFT) during implant and/or replacement of implantable cardioverter-defibrillators (ICDs) has been a matter of debate for many years. This debate was put to rest by the Simple and the Nordic ICD trials, and the practice of testing during new implantations has practically been nearly abandoned. Nevertheless, induction of VF for testing purposes (VFT) may still have an important role in selective populations at risk for defibrillation failure, who were not included in the SIMPLE and Nordic trials. One such population includes those who undergo device replacements. Old registries demonstrated an increased incidence of significant findings in VFT during replacements. In the present study, we sought to test this observation. Objectives Evaluate frequency of significant findings and the safety of VFT in subjects undergoing device replacement. Methods A prospective observational multi-center study of VFT included consecutive patients undergoing ICD generator replacement in 5 centers in Israel, Europe, and the US. All centers followed the same VFT protocol. The primary outcome was defined as failure to terminate induced VF with a single shock at 10 Joules below the maximal capacity of the device. Secondary outcomes included complications of VFT. Patients were followed-up at 1 month and 6 months post-procedure. Data collection included documentation of any peri-operative complications and clinical endpoints (occurrence of appropriate shock, inappropriate shocks, lead failure, need for re-intervention, and infection). Results A total of 92 patients were eligible, and consented for the study, of which 84 underwent DFT during battery replacement. The median age was 68 years and 79.8% were male subjects. Induction of VF was successful in all 84 patients as well as VFT with a successful conversion on first attempt. During follow up one patient had two appropriate ICD shock events. In four patients, the ICD programming was changed. None suffered an inappropriate shock. There was no evidence of lead malfunction. A total of two deaths occurred, none of which were related to the device. Conclusion The present study found VFT was not associated with complications in patients undergoing ICD/CRTD generator replacement but produced no clinically important information.
Radial strain imaging-guided lead placement for improving response to cardiac resynchronization therapy in patients with ischaemic cardiomyopathy: the Raise CRT trial
Glikson, Michael , Beinart, Roy , Golovchiner, Gregory , Sheshet, Alon Bar, Bolous, Munther, Rosso, Raphaël , Medina, Aharon , Haim, Moti , Friedman, Paul A. , Khalamaizer, Vladimir, Ben‐Zvi, Shlomit, Klempfner, Robert , Vaturi, Ori, Oh, Jae K. , Ito, Saki , Goldenberg, Ilan , Beinart, Roy , Haim, Moti , Glikson, Michael , Swissa, Moshe , Goldenberg, Ilan

EP Europace | September 30, 2021 | Volume: 24 | Issue: 5 | Pages: 835-844

10.1093/europace/euab253 Get It

Abstract Aims To evaluate the benefit of speckle tracking radial strain imaging (STRSI)-guided left ventricular (LV) lead (LVL) positioning in cardiac resynchronization therapy (CRT) in patients (pts) with ischaemic cardiomyopathy with CRT indication. Methods and results We conducted a prospective randomized controlled trial. Patients were enrolled in nine centres with 2:1 randomization into two groups (guided vs. control). Patients underwent STRSI to identify the optimal LV position from six LV segments at midventricular level. Implantation via STRSI was attempted for recommended segment in the guided group only. Follow-up included echocardiography (6 months) and clinical evaluation (6 and 12 months). The primary endpoint was comparison % reduction in LV end-systolic volume at 6 months with baseline. Secondary endpoints included hospitalizations for heart failure and death, and improvement in additional echocardiographic measurements and quality of life score. A total of 172 patients (115 guided vs. 57 control) were enrolled. In the guided group, 60% of the implanted LV leads were adjudicated to be successfully located at the recommended segment, whereas in the control group 44% reached the best STRSI determined segment. There was no difference between the groups in any of the primary or secondary endpoints at 6 and 12 months. Conclusion Our findings suggest that echo-guided implantation of an LV lead using STRSI does not improve the clinical or echocardiographic response compared with conventional implantation.