ABSTRACT Background A novel individualized antitachycardia pacing (IATP) algorithm using the post‐pacing interval for real‐time control has been introduced. Performance information is limited to a small safety and feasibility study with additional single‐center and case studies. A larger‐scale analysis is needed to better understand algorithm performance. Methods Deidentified remote monitoring transmissions from devices with the IATP therapy applied were randomly selected. Rhythms were classified and effects of the novel algorithm were assessed. For monomorphic ventricular tachycardias (MVTs) proportions of successful therapy, shock‐free episodes, and acceleration were calculated using generalized estimating equations to correct for multiple episodes and compute statistics of the algorithm's performance. Results There were 2259 MVT episodes in 336 patients. IATP succeeded in 87.1% of MVT episodes with 89.9% of MVT episodes ultimately free of shock therapy. Based on multivariate analysis, significant factors in therapy success were programming of at least the recommended number of sequences (90% at least recommended vs 73%, p = 0.00088) and female sex (95% for females vs 86%, p = 0.002). A trend to higher success was found for MVT with a cycle length of 320 ms or greater (90% vs. 83%, p = 0.10). The IATP accelerated 3.6% of MVT episodes. None of the available factors was significantly associated with acceleration in the multivariate analysis. Conclusions The IATP algorithm succeeded in a large proportion of MVT episodes and with low acceleration in patients randomly selected from remote monitoring transmissions. Using at least the recommended number of sequences had the strongest association with successful therapy.
Real-world performance of a fully automatic antitachycardia pacing algorithm
Abstract Background Antitachycardia pacing (ATP) found in most implantable cardioverter defibrillators (ICDs) is an important therapy for painless termination of ventricular tachycardias (VT). In ICDs programmed to guideline-recommended detection and therapy settings typical ATP success rates are 50-70%.[1-3] The first closed-loop, automated ATP (AATP) algorithm, introduced in 2021, applies an S1 train derived from the detected VT, followed by an S2 derived initially from a refractory period estimator and then adjusted using analysis of the post-pacing interval if ATP fails. The termination efficacy of AATP in the real-world population is unknown. Purpose To assess the effectiveness AATP in a large real-world population. Methods A database of de-identified ICD transmissions from subjects in the United States, Australia, Canada, and New Zealand was queried for AATP treated episodes. ICDs were randomly sampled, biased toward ICDs with multiple treated VT episodes. For rhythms classified as monomorphic ventricular tachycardia, each AATP pulse train was reviewed for: rhythm at delivery, effect of ATP, and any non-capturing pulses. Acceleration was defined as a post-ATP decrease in MVT cycle length (VTCL) of at least 10% and at least 30ms. Acceleration to polymorphic VT or ventricular fibrillation (PVT/VF) was assessed. Rates of termination and acceleration were calculated for all MVT and dichotomized using a 320ms VTCL cutoff. The method of generalized estimating equations (GEE) was used to correct event rates for multiple episodes from a single patient. Results There were 2281 episodes of MVT in 340 patients; 63% of patients had 2 or more episodes. There were 724 episodes with initial VTCL <320ms and 1557 episodes with VTCL ≥320ms. The rate of termination of MVT by AATP was 78% for all VTCL [95% CI: 74%-81%]. In 300 patients (88%) AATP terminated at least one MVT. For MVT with VTCL ≥320ms the termination rate was 80% [95% CI: 75%-83%] and for VTCL <320ms the termination rate was 75% [95% CI: 69%-80%]. The rate of acceleration was 3.6% [95% CI: 2.7%-4.9%], with a 0.8% rate of acceleration to PVT/VF [95% CI: 0.4%-1.8%]. Acceleration led to shock therapy in 63% of accelerated episodes. All MVT accelerated to PVT/VF either spontaneously terminated (4/14) or were successfully converted by a single shock therapy (10/14). All accelerations that remained MVT were successfully treated by the device with either subsequent ATP (35%) or shock therapy (61%), or spontaneously terminated (4%). Conclusion In this large, real-world cohort analysis, automated ATP’s termination rate exceeded the typical success rate of burst ATP, particularly for MVT <320ms. Acceleration to PVT/VF was low and effective first-shock defibrillation was consistent. Subsequent ATP for accelerated MVT had incremental benefit, leading to successful termination one-third of the time. Additional data are currently being prospectively collected in a separate post-approval study.
Abstract Introduction Chronic right ventricular pacing (RVP) has been associated with dyssynchrony, leading to increased mortality. However, there have been discrepancies in previous reports in the effect of RVP levels. Objective To sub-stratify mortality risk by age for different RVP level groups within a large real-world ICD cohort. Methods Optum® de-identified electronic health records were linked to the Medtronic Carelink data to identify dual chamber ICD recipients (2007–2017). RVP level was based on median daily pacing during the first 90 days post-implant and categorized either into groups with a cutoff of 40%, or with groups of 0–9%, 10–19%, 20–29%, 30–39%, 40–49%, and 50–100%. The endpoint was death more than 90 days post-implant. Kaplan-Meier survival curves, log-rank tests, and Cox regression were used to analyze the relationship between RVP and risk of death. Results Among 14,832 ICD patients (median age 67; 74.0% male), there were 2,602 deaths within 10 years after implant. In unadjusted comparisons, high RVP (>40%) increased the risk of death relative to low RVP (≤40%) (p<0.001). This effect remained significant in older cohort (≥67 years old at implant) (p<0.001), but not in younger cohort (<67 years old) (p=0.955) (Figure). After controlling for age, gender, pacing mode, MI, SCA, HF hospitalization, diabetes, and renal dysfunction, similar or increased risk was associated with higher pacing groups relative to the 0–9% pacing group in the older cohort, but not in the younger cohort. Conclusions Our data from a large contemporaneous real-world source suggests that older age or characteristics associated with age make patients more sensitive to chronic RVP effects. These results help reconcile differences observed in prior studies. Funding Acknowledgement Type of funding source: Private company. Main funding source(s): Medtronic, Inc.
849. Reduced CIED Infections with an Antibacterial Envelope: Microbiologic Analysis of the WRAP-IT Study
Abstract Background Cardiovascular implantable electronic device (CIED) infections are associated with significant morbidity, mortality, and cost. There is limited evidence on antibiotic prophylactic strategies to prevent CIED infection. Recently, the TYRX Envelope, which elutes a combination of rifampin and minocycline for a minimum of 7 days, was shown to significantly reduce major CIED infections in the WRAP-IT trial. We sought to characterize the pathogens among patients who experienced an infection in the current era. Methods All patients undergoing CIED replacement, upgrade, revision, or de novo cardiac resynchronization therapy (CRT-D) received standard of care antibiotic prophylaxis and were randomized 1:1 to receive TYRX or not. The primary endpoint was major CIED infection within 12 months of the procedure. Major infection was defined as an infection resulting in (1) system extraction or revision, (2) long-term suppressive antibiotic therapy, or (3) death. Data were analyzed using the Cox proportional hazards regression model. Results A total of 6,983 patients were randomized worldwide with 3,495 randomized to receive an envelope and 3,488 randomized to the control. At 12 months, 25 major infections (0.7%) were observed in the envelope group and 42 major infections (1.2%) in the control group, resulting in a 40% reduction of major infections (HR: 0.60, 95% CI: 0.36–0.98, P = 0.04). Of 63 infections assayed, causative pathogens were identified in 36 infections whereas cultures were negative in 27 cases. Staphylococcus species (n = 22) were the predominate pathogens and a 53% reduction was observed with the use of TYRX (Figure 1). Moreover, there was only 1 CIED pocket infection with Staphylococcus species in the envelope group compared with 14 pocket infections in the control group. A comparison of timing of infection in the envelope group showed the presence of 11 endocarditis/bacteremia infections at 103 ± 84 days compared with 14 pocket infections presenting at 70 ± 78 days from the procedure. Conclusion In this large randomized trial, the use of the TYRX Envelope containing rifampin and minocycline resulted in a significant reduction of major CIED infections and was effective against staphylococcal species, which are the predominant cause of pocket infections. Disclosures All Authors: No reported Disclosures.
Safety of Sports for Athletes With Implantable Cardioverter-Defibrillators
Background— The risks of sports participation for implantable cardioverter-defibrillator (ICD) patients are unknown. Methods and Results— Athletes with ICDs (age, 10–60 years) participating in organized (n=328) or high-risk (n=44) sports were recruited. Sports-related and clinical data were obtained by phone interview and medical records. Follow-up occurred every 6 months. ICD shock data and clinical outcomes were adjudicated by 2 electrophysiologists. Median age was 33 years (89 subjects <20 years of age); 33% were female. Sixty were competitive athletes (varsity/junior varsity/traveling team). A pre-ICD history of ventricular arrhythmia was present in 42%. Running, basketball, and soccer were the most common sports. Over a median 31-month (interquartile range, 21–46 months) follow-up, there were no occurrences of either primary end point—death or resuscitated arrest or arrhythmia- or shock-related injury—during sports. There were 49 shocks in 37 participants (10% of study population) during competition/practice, 39 shocks in 29 participants (8%) during other physical activity, and 33 shocks in 24 participants (6%) at rest. In 8 ventricular arrhythmia episodes (device defined), multiple shocks were received: 1 at rest, 4 during competition/practice, and 3 during other physical activity. Ultimately, the ICD terminated all episodes. Freedom from lead malfunction was 97% at 5 years (from implantation) and 90% at 10 years. Conclusions— Many athletes with ICDs can engage in vigorous and competitive sports without physical injury or failure to terminate the arrhythmia despite the occurrence of both inappropriate and appropriate shocks. These data provide a basis for more informed physician and patient decision making in terms of sports participation for athletes with ICDs.