Back to Authors

Greenspon, Arnold J.

https://orcid.org/0000-0002-6877-6118

Mayo Clinic

Thomas Jefferson University

Citations 9

849. Reduced CIED Infections with an Antibacterial Envelope: Microbiologic Analysis of the WRAP-IT Study
Corey, G. Ralph, Poole, Jeanne E. , Kennergren, Charles , Greenspon, Arnold J. , Cheng, Alan , Lande, Jeff , Lexcen, Daniel R. , Tarakji, Khaldoun G. , Sohail, M. Rizwan , Wilkoff, Bruce L. , Mittal, Suneet

Open Forum Infectious Diseases | October 23, 2019 | Volume: 6 | Issue: Supplement_2 | Pages: S16-S16

10.1093/ofid/ofz359.034 Get It

Abstract Background Cardiovascular implantable electronic device (CIED) infections are associated with significant morbidity, mortality, and cost. There is limited evidence on antibiotic prophylactic strategies to prevent CIED infection. Recently, the TYRX Envelope, which elutes a combination of rifampin and minocycline for a minimum of 7 days, was shown to significantly reduce major CIED infections in the WRAP-IT trial. We sought to characterize the pathogens among patients who experienced an infection in the current era. Methods All patients undergoing CIED replacement, upgrade, revision, or de novo cardiac resynchronization therapy (CRT-D) received standard of care antibiotic prophylaxis and were randomized 1:1 to receive TYRX or not. The primary endpoint was major CIED infection within 12 months of the procedure. Major infection was defined as an infection resulting in (1) system extraction or revision, (2) long-term suppressive antibiotic therapy, or (3) death. Data were analyzed using the Cox proportional hazards regression model. Results A total of 6,983 patients were randomized worldwide with 3,495 randomized to receive an envelope and 3,488 randomized to the control. At 12 months, 25 major infections (0.7%) were observed in the envelope group and 42 major infections (1.2%) in the control group, resulting in a 40% reduction of major infections (HR: 0.60, 95% CI: 0.36–0.98, P = 0.04). Of 63 infections assayed, causative pathogens were identified in 36 infections whereas cultures were negative in 27 cases. Staphylococcus species (n = 22) were the predominate pathogens and a 53% reduction was observed with the use of TYRX (Figure 1). Moreover, there was only 1 CIED pocket infection with Staphylococcus species in the envelope group compared with 14 pocket infections in the control group. A comparison of timing of infection in the envelope group showed the presence of 11 endocarditis/bacteremia infections at 103 ± 84 days compared with 14 pocket infections presenting at 70 ± 78 days from the procedure. Conclusion In this large randomized trial, the use of the TYRX Envelope containing rifampin and minocycline resulted in a significant reduction of major CIED infections and was effective against staphylococcal species, which are the predominant cause of pocket infections. Disclosures All Authors: No reported Disclosures.
121. Cardiac Implantable Electronic Device-Related Infective Endocarditis (CIED-IE): Clinical Features and Outcomes of Patients with Definite IE Who Fulfill Both Major Duke Criteria
Gupta, Siddhi , Wierzba, Thomas F. , Peacock, James E. , Le, Katherine, Miró, José M., Prutkin, Jordan M. , Greenspon, Arnold J. , Danik, Stephan B., Naber, Christoph, Blank, Elisabeth, Tseng, Chi‐Hong , Baddour, Larry M. , Sohail, M. Rizwan , Vikram, Holenarasipur R. , Carrillo, Roger G. , Uslan, Daniel Z.

Open Forum Infectious Diseases | October 23, 2019 | Volume: 6 | Issue: Supplement_2 | Pages: S91-S91

10.1093/ofid/ofz360.196 Get It

Abstract Background Cardiac implantable electronic device-related infective endocarditis (CIED-IE) comprises 10–57% of total CIED infections. Patients with definite CIED-IE who fulfill both major modified Duke criteria have not been well characterized. Methods Data from the Multicenter Electrophysiologic Device Infection Cohort, a prospective, multinational study of CIED infections were used to describe a subset of patients with CIED-IE who met both major Duke criteria for definite IE (bloodstream infection and intracardiac vegetations [VEG]). Results Of 433 patients with CIED infection, 144 (33.3%) had definite CIED-IE. The median age was 68 years and 77.1% were male. Twelve (8.3%) had past CIED infection. Seventy-seven patients (53.5%) had permanent pacemakers, 38 (26.4%) had implantable cardioverter defibrillators, and 29 (20.1%) had combination devices. The median time following the last device procedure was 550 days. CIED-IE was early in 60 patients (41.7%) and late in 84 (58.3%). Most patients presented with fever (77.8%) and sepsis (44.4%) with a median symptom duration of 7 days. On echocardiography, lead VEG was noted in 125 patients (86.8%) and valvular VEG in 54 patients (37.5%) with the tricuspid valve involved in 56.5%. On the basis of VEG location, there were 90 patients (62.5%) with isolated lead-associated IE (LAE), 19 patients (13.2%) with isolated valve-associated IE (VAE), and 35 patients (24.3%) with both (LVAE). All patients had positive blood cultures and 63/119 (52.9%) had positive lead cultures. The predominant organism in blood was Staphylococcus aureus (42.4%), followed by coagulase-negative staphylococci (20.1%). CIED removal occurred in 131 patients (91%). There were 25 deaths during the index hospitalization and 34 total deaths (24.3%) by 6 months. Mortality correlated with age >75 (P = 0.023) and sepsis on presentation (P = 0.052). Infecting organism, site of VEG, and device removal did not impact the risk of death. Conclusion Definite CIED-IE is relatively common. The majority of patients tend to have late-onset infection and often present with sepsis. S. aureus is the dominant organism causing definite CIED-IE. Isolated LAE occurs in 63% of patients. Older age and sepsis on admission are associated with higher mortality. Disclosures All authors: No reported disclosures.
Cardiovascular implantable electronic device infections due to enterococcal species: Clinical features, management, and outcomes
Oh, Timothy S. , Le, Katherine, Sohail, M. Rizwan , Vikram, Holenarasipur R. , Hernández‐Meneses, Marta , Prutkin, Jordan M. , Greenspon, Arnold J. , Carrillo, Roger G. , Danik, Stephen B., Naber, Christoph, Blank, Elisabeth, Tseng, Chi‐Hong , Uslan, Daniel Z. , Peacock, James E. , Greenspon, Arnold J , Peacock, James E , Vikram, Holenarasipur R. , Sohail, M Rizwan , Oh, Timothy S., Baddour, Larry M. , Miró, José María

Pacing and Clinical Electrophysiology | August 19, 2019 | Volume: 42 | Issue: 10 | Pages: 1331-1339

10.1111/pace.13783 Get It

AbstractBackgroundEnterococcal cardiovascular implantable electronic device (CIED) infections are not well characterized.MethodsData from the Multicenter Electrophysiologic Device Infection Cohort, a prospective study of CIED infections, were used for descriptive analysis of adults with enterococcal CIED infections.ResultsOf 433 patients, 21 (4.8%) had enterococcal CIED infection. Median age was 71 years. Twelve patients (57%) had permanent pacemakers, five (24%) implantable cardioverter defibrillators, and four (19%) biventricular devices. Median time from last procedure to infection was 570 days. CIED‐related bloodstream infections occurred in three patients (14%) and 18 (86%) had infective endocarditis (IE), 14 (78%) of which were definite by the modified Duke criteria. IE cases were classified as follows: valvular IE, four; lead IE, eight; both valve and lead IE, six. Vegetations were demonstrated by transesophageal echocardiography in 17 patients (81%). Blood cultures were positive in 19/19 patients with confirmed results. The most common antimicrobial regimen was penicillin plus an aminoglycoside (33%). Antibiotics were given for a median of 43 days. Only 14 patients (67%) underwent device removal. There was one death during the index hospitalization with four additional deaths within 6 months (overall mortality 24%). There were no relapses.ConclusionsEnterococci caused 4.8% of CIED infections in our cohort. Based on the late onset after device placement or manipulation, most infections were likely hematogenous in origin. IE was the most common infection syndrome. Only 67% of patients underwent device removal. At 6 months follow‐up, no CIED infection relapses had occurred, but overall mortality was 24%.
1085. Enterococcal Cardiac Implantable Electronic Device (CIED) Infections: Clinical Features and Outcomes
Oh, Timothy S. , Peacock, James E. , Le, Katherine, Prutkin, Jordan M. , Greenspon, Arnold J. , Danik, Stephan B., Naber, Christoph, Blank, Elisabeth, Tseng, Chi‐Hong , Sohail, M. Rizwan , Baddour, Larry M. , Vikram, Holenarasipur R. , Miró, José María , Carrillo, Roger G. , Uslan, Daniel Z.

Open Forum Infectious Diseases | November 26, 2018 | Volume: 5 | Issue: suppl_1 | Pages: S325-S325

10.1093/ofid/ofy210.920 Get It

Abstract Background Unlike enterococcal native and prosthetic valve infective endocarditis (IE), enterococcal CIED infections are not well described. Methods Data from the Multicenter Electrophysiologic Device Infection Collaboration (MEDIC), a prospective, observational, multinational cohort study of CIED infections, were used to provide a descriptive analysis of adult patients with CIED infections due to enterococcal species. Results Of 433 patients, 21 (4.8%) were diagnosed with enterococcal CIED infection. Specific data on enterococcal species and antimicrobial susceptibilities were not recorded. The mean age was 70.8 years. No patient had previous CIED infection. Twelve patients (57%) had permanent pacemakers, 5 (24%) had implantable cardioverter defibrillators, and 4 (19%) had biventricular devices. Among the 21 infections, 3 (14%) were categorized as CIED-related bloodstream infections and 18 (86%) as IE; no patient had isolated pocket infection. Of the IE cases, four were valvular IE, eight were lead IE, and six were both. Fourteen cases of IE (78%) were definite by the modified Duke criteria. Median time from last device procedure to infection was 510 days (range 37–2,952 days). The most common presenting symptom was fever (48%); five patients (24%) exhibited local signs of pocket infection. All 21 patients underwent TEE with vegetations demonstrated in 17 (81%). Blood cultures grew enterococci from all patients. The most common antimicrobial regimen was a penicillin plus aminoglycoside (38%); two patients (9.5%) received ampicillin + ceftriaxone. Antibiotics were given for a median of 43 days. Only 14 patients (67%) had complete device removal; the seven patients retaining their device were judged to be at high risk for extraction. There was one death during the index hospital stay with four additional patients dying over the 6 months after therapy (overall mortality 24%); two of the seven patients retaining their CIED died. Conclusion Enterococci caused 4.8% of all CIED infections in our cohort. Most infections appeared to be hematogenous in origin with late onset. IE was the most common infectious syndrome. A penicillin plus aminoglycoside, given for 6 weeks, was the most frequent therapy. Only 67% of patients underwent device removal. At 6 months follow-up, no relapses had occurred but overall mortality was 24%. Disclosures J. E. Peacock Jr., Pfizer, Inc.: Shareholder, Owns common stock in Pfizer which was inherited and held in a trust. M. R. Sohail, TyRx Inc.: Investigator, Research support. Medtronic Inc.: Investigator, Research support. Medtronic Inc.: Consultant, Speaker honorarium. Spectranetics: Consultant, Speaker honorarium. Boston Scientific Corp: Consultant, Speaker honorarium. L. M. Baddour, UpToDate: Collaborator, Royalty payment. J. M. Miro, Abbvie: Consultant and Grant Investigator, Consulting honoraria and Research grant. Bristol-Myers Squibb: Consultant and Grant Investigator, Consulting honoraria and Research grant. Genentech: Consultant and Grant Investigator, Consulting honoraria and Research grant. Medtronic: Consultant and Grant Investigator, Consulting honoraria and Research grant. Novartis: Consultant and Grant Investigator, Consulting honoraria and Research grant. Gilead Sciences: Consultant and Grant Investigator, Consulting honoraria and Research grant. Pfizer: Consultant and Grant Investigator, Consulting honoraria and Research grant. ViiV Healthcare: Consultant and Grant Investigator, Consulting honoraria and Research grant. A. J. Greenspon, Medtronic: Consultant, Speaker honorarium. Boston Scientific: Consultant, Speaker honorarium. St. Jude: Consultant, Speaker honorarium. R. G. Carrillo, St. Jude Medical Group: Speaker’s Bureau, Research support. Spectranetics: Consultant, Speaker honorarium. Sorin Group: Speaker’s Bureau, None. Boston Scientific Corp: Speaker’s Bureau, None. D. Z. Uslan, Medtronic: Investigator, Research support. Boston Scientific: Consultant, Speaker honorarium.
Clinical presentation of CIED infection following initial implant versus reoperation for generator change or lead addition
Harper, Mariko W. , Uslan, Daniel Z. , Greenspon, Arnold J. , Danik, Stephan B., Le, Katherine, Miró, José M., Naber, Christoph, Peacock, James E. , Vikram, Holenarasipur R. , Prutkin, Jordan M. , Vikram, Holenarasipur R. , Baddour, Larry M. , Carrillo, Roger G. , Tolosana, Jose María , Sohail, M. Rizwan

Open Heart | March 30, 2018 | Volume: 5 | Issue: 1 | Pages: e000681

10.1136/openhrt-2017-000681 Get It

Objective To explore differences in clinical manifestations and outcomes in those patients who develop infection after undergoing initial implantation versus reoperation. Methods We compared cases of cardiac implantable electronic device (CIED) infection based on initial implantation versus reoperation from 11 centres. Results There were 432 patients with CIED infection, 178 occurring after initial device placement and 254 after repeat reoperation. No differences were seen in age, sex or device type. Those with infection after initial implant had a higher Charlson Comorbidity Score (median 3 (IQR 2–6) vs 2 (IQR 1–4), p<0.001), shorter time since last procedure (median 8.9 months (IQR 0.9–33.3) vs 19.5 months (IQR 1.1–62.9), p<0.0001) and fewer leads (2.0±0.6vs 2.5±0.9, p<0.001). Pocket infections were more likely to occur after a reoperation (70.1%vs48.9%, p<0.001) and coagulase negative staphylococci (CoNS) was the most frequently isolated organism in this group (p=0.029). In contrast, initial implant infections were more likely to present with higher white cell count (10.5±5.1 g/dL vs 9.5±5.4 g/dL, p=0.025), metastatic foci of infection (16.9%vs8.7%, p=0.016) and sepsis (30.9%vs19.3%, p=0.006). There were no differences in in-hospital (7.9%vs5.2%, p=0.31) or 6-month mortality (21.9%vs14.0%, p=0.056). Conclusions CIED infections after initial device implant occur earlier, more aggressively, and often due to Staphylococcus aureus. In contrast, CIED infections after reoperation occur later, are due to CoNS, and have more indolent manifestations with primary localisation to the pocket.
Attempted salvage of infected cardiovascular implantable electronic devices: Are there clinical factors that predict success?
Peacock, James E. , Stafford, Jeanette M. , Le, Katherine, Sohail, M. Rizwan , Prutkin, Jordan M. , Danik, Stephan B., Vikram, Holenarasipur R. , Hernández‐Meneses, Marta , Blank, Elisabeth, Naber, Christoph, Carrillo, Roger G. , Greenspon, Arnold J. , Tseng, Chi‐Hong , Uslan, Daniel Z. , Vikram, Holenarasipur R. , Sohail, M Rizwan , Baddour, Larry M. , Miró, José María

Pacing and Clinical Electrophysiology | March 8, 2018 | Volume: 41 | Issue: 5 | Pages: 524-531

10.1111/pace.13319 Get It

AbstractBackgroundPublished guidelines mandate complete device removal in cases of cardiovascular implantable electronic device (CIED) infection. Clinical predictors of successful salvage of infected CIEDs have not been defined.MethodsData from the Multicenter Electrophysiologic Device Infection Collaboration, a prospective, observational, multinational cohort study of CIED infection, were used to investigate whether clinical predictors of successful salvage of infected devices could be identified.ResultsOf 433 adult patients with CIED infections, 306 (71%) underwent immediate device explantation. Medical management with device retention and antimicrobial therapy was initially attempted in 127 patients (29%). “Early failure” of attempted salvage occurred in 74 patients (58%) who subsequently underwent device explantation during the index hospitalization. The remaining 53 patients (42%) in the attempted salvage group retained their CIED. Twenty‐six (49%) had resolution of CIED infection (successful salvage group) whereas 27 patients (51%) experienced “late” salvage failure. Upon comparing the salvage failure group, early and late (N = 101), to the group experiencing successful salvage of an infected CIED (N = 26), no clinical or laboratory predictors of successful salvage were identified. However, by univariate analysis, coagulase‐negative staphylococci as infecting pathogens (P = 0.0439) and the presence of a lead vegetation (P = 0.024) were associated with overall failed salvage.ConclusionsIn patients with definite CIED infections, clinical and laboratory variables cannot predict successful device salvage. Until new data are forthcoming, device explantation should remain a mandatory and early management intervention in patients with CIED infection in keeping with existing expert guidelines unless medical contraindications exist or patients refuse device removal.
Treatment patterns, costs, and mortality among Medicare beneficiaries with CIED infection
Greenspon, Arnold J. , Eby, Elizabeth L. , Petrilla, Allison , Sohail, M. Rizwan , Petrilla, Allison A , Sohail, M Rizwan

Pacing and Clinical Electrophysiology | February 7, 2018 | Volume: 41 | Issue: 5 | Pages: 495-503

10.1111/pace.13300 Get It

AbstractBackgroundCardiac implantable electronic device (CIED) infection is a serious adverse event, but there are limited contemporary real‐world data on treatment pathways and associated costs in the Medicare population following diagnosis of CIED infection. Hence, this study evaluates postinfection treatment pathways and associated healthcare expenditures and mortality among Medicare fee‐for‐service beneficiaries with CIED infection.MethodsRetrospective cohort analysis of 5,401 beneficiaries who developed a device‐related infection in the year following implantation/upgraded CIED (1/1/2010–12/31/2012). Patients were followed‐up to 12 months/death following diagnosis of infection and were divided into mutually exclusive groups based on whether they underwent CIED system removal (Group I), or no CIED system intervention (Group II; IIA with or IIB without infection hospitalization). All‐cause healthcare resource utilization/expenditures were also measured.ResultsIn the year following infection, 64.1% of patients underwent device extraction, of who 2,109 (39.0%) had their device replaced (Group IA) and 1,355 (25.1%) had their device extracted without replacement (Group IB); 62.2% of patients were hospitalized and 25.3% of patients died. Mean Medicare payments‐per‐patient for facility‐based services by group were: IA = $62,638 (standard deviation [SD]: $46,830), IB = $50,079 (SD: $45,006), IIA = $77,397 (SD: $79,130), and IIB = $22,856 (SD: $31,167).ConclusionsHospitalizations were the largest cost driver; infection‐related costs, including cost of extraction/replacement, accounted for >50% of expenditures for patients with surgical/hospital intervention. Management of CIED infection in Medicare beneficiaries is associated with high healthcare expenditures in the year following infection. Additional measures to prevent device infection are needed to improve the outcomes and reduce costs in these patients.
Incidence, Treatment Intensity, and Incremental Annual Expenditures for Patients Experiencing a Cardiac Implantable Electronic Device Infection
Sohail, M. Rizwan , Eby, Elizabeth L. , Ryan, Michael P. , Gunnarsson, Candace , Greenspon, Arnold J. , Wright, Laura A, Wright, Laura A. , Sohail, M Rizwan

Circulation: Arrhythmia and Electrophysiology | August 9, 2016 | Volume: 9 | Issue: 8 | Pages: No page available

10.1161/circep.116.003929 Get It

Background— Because of the increasing use of cardiac implantable electronic devices (CIEDs), it is important to estimate the incidence and annual healthcare expenditures associated with CIED infections. Methods and Results— Patients with a record of an initial or replacement (full implant or generator only) CIED implant during the calendar years 2009 to 2012 in MarketScan Commercial Claims and Medicare Supplemental database were identified. CIED infections were classified into 4 categories: (1) infection not managed by inpatient admission nor implant removal, (2) infection managed by inpatient admission but no implant removal, (3) infection managed by an implant removal either in an inpatient or in an outpatient setting, and (4) infection with severe sepsis and managed in an inpatient setting with implant removal. Using separate models for initial and replacement cohorts, annualized incidence of infection and incremental annual expenditures by treatment intensity were estimated. Cumulative incidence of infection at 1 year post implant was 1.18% for initial CIED implants and 2.37% for replacement. Median time to infection was 35 days for initial and 23 days for replacement. Incremental healthcare expenditures by treatment intensity categories for initial implant patients at 1 year were $16 651, $104 077, $45 291, and $279 744. For replacement patients, incremental expenditures at 1 year by treatment intensity categories were $26 857, $43 541, $48 759, and $362 606. Conclusions— The management of CIED infections results in a substantial healthcare burden with a significant increase in annual expenditures the year after implant when device infection occurs.
Variability in Clinical Features of Early Versus Late Cardiovascular Implantable Electronic Device Pocket Infections
Welch, M P, Uslan, Daniel Z. , Greenspon, Arnold J. , Sohail, M. Rizwan , Blank, Elisabeth, Carrillo, Roger G. , Danik, Stephan B., Lechuga, Ana del Río , Hellinger, Walter C. , Le, Katherine, Naber, Christoph, Peacock, James E. , Vikram, Holenarasipur R. , Tseng, Chi‐Hong , Prutkin, Jordan M. , Investigators, for the MEDIC, Baddour, Larry M. , Miró, José María , Vikram, Holenarasipur R. , Investigators, for the MEDIC, Sohail, M Rizwan

Pacing and Clinical Electrophysiology | March 25, 2014 | Volume: 37 | Issue: 8 | Pages: 955-962

10.1111/pace.12385 Get It

Background Cardiovascular implantable electronic device (CIED) pocket infections are often related to recent CIED placement or manipulation, but these infections are not well characterized. The clinical presentation of CIED pocket infection, based on temporal onset related to last CIED procedure, deserves further study. Methods The MEDIC (Multicenter Electrophysiologic Device Infection Cohort) prospectively enrolled subjects with CIED infection. Subjects were stratified into those whose infection occurred <12 months (early) or ≥12 months (late) since their last CIED‐related procedure. Results There were 132 subjects in the early group and 106 in the late group. There were more females (P = 0.009) and anticoagulation use (P = 0.039) in the early group. Subjects with early infections were more likely to have had a generator change or lead addition as their last procedure (P = 0.03) and had more prior CIED procedures (P = 0.023). Early infections were more likely to present with pocket erythema (P < 0.001), swelling (P < 0.001), and pain (P = 0.007). Late infections were more likely to have pocket erosion (P = 0.005) and valvular vegetations (P = 0.009). In bacteremic subjects, early infections were more likely healthcare‐associated (P < 0.001). In‐hospital and 6‐month mortality were equivalent. Conclusion A total of 45% of patients with CIED pocket infection presented >12 months following their last CIED‐related procedure. Patients with early infection were more likely to be female, on anticoagulation, and present with localized inflammation, whereas those with late infection were more likely to have CIED erosion or valvular endocarditis.