Back to Authors

Lande, Jeff

https://orcid.org/0000-0002-9584-610X

Mayo Clinic

Medtronic (United States)

Citations 2

New atrial arrhythmia occurrence in single chamber implantable cardioverter defibrillator patients: A real‐world investigation
Patel, Divyang , Friedman, Paul A. , Deshmukh, Abhishek , Lande, Jeff , Brown, Mark L., Lexcen, Daniel R. , Friedman, Paul A , Deshmukh, Abhishek J , Rao, Archana , Murphy, Jeffrey A., Brown, Mark L., Wilkoff, Bruce L.

Journal of Cardiovascular Electrophysiology | December 29, 2022 | Volume: 34 | Issue: 2 | Pages: 438-444

10.1111/jce.15790 Get It

AbstractIntroductionA current limitation of single chamber implantable cardioverter defibrillators (ICDs) is the lack of an atrial lead to reliably detect atrial fibrillation (AF) episodes. A novel ventricular based atrial fibrillation (VBAF) detection algorithm was created for single chamber ICDs to assess R‐R variability for detection of AF.MethodsPatients implanted with Visia AF™ ICDs were prospectively enrolled in the Medtronic Product Surveillance Registry from December 15, 2015 to January 23, 2019 and followed with at least 30 days of monitoring with the algorithm. Time to device‐detected daily burden of AF ≥ 6 min, ≥6 h, and ≥23 h were reported. Clinical actions after device‐detected AF were recorded.ResultsA total of 291 patients were enrolled with a mean follow‐up of 22.5 ± 7.9 months. Of these, 212 (73%) had no prior history of AF at device implant. However, 38% of these individuals had AF detected with the VBAF algorithm with daily burden of ≥6 min within two years of implant. In these 80 patients with newly detected AF by their ICD, 23 (29%) had a confirmed clinical diagnosis of AF by their provider. Of patients with a clinical diagnosis of AF, nine (39%) were newly placed on anticoagulation, including five of five (100%) patients having a burden >23 h.ConclusionsContinuous AF monitoring with the new VBAF algorithm permits early identification and actionable treatment for patients with undiagnosed AF that may improve patient outcomes.
849. Reduced CIED Infections with an Antibacterial Envelope: Microbiologic Analysis of the WRAP-IT Study
Corey, G. Ralph, Poole, Jeanne E. , Kennergren, Charles , Greenspon, Arnold J. , Cheng, Alan , Lande, Jeff , Lexcen, Daniel R. , Tarakji, Khaldoun G. , Sohail, M. Rizwan , Wilkoff, Bruce L. , Mittal, Suneet

Open Forum Infectious Diseases | October 23, 2019 | Volume: 6 | Issue: Supplement_2 | Pages: S16-S16

10.1093/ofid/ofz359.034 Get It

Abstract Background Cardiovascular implantable electronic device (CIED) infections are associated with significant morbidity, mortality, and cost. There is limited evidence on antibiotic prophylactic strategies to prevent CIED infection. Recently, the TYRX Envelope, which elutes a combination of rifampin and minocycline for a minimum of 7 days, was shown to significantly reduce major CIED infections in the WRAP-IT trial. We sought to characterize the pathogens among patients who experienced an infection in the current era. Methods All patients undergoing CIED replacement, upgrade, revision, or de novo cardiac resynchronization therapy (CRT-D) received standard of care antibiotic prophylaxis and were randomized 1:1 to receive TYRX or not. The primary endpoint was major CIED infection within 12 months of the procedure. Major infection was defined as an infection resulting in (1) system extraction or revision, (2) long-term suppressive antibiotic therapy, or (3) death. Data were analyzed using the Cox proportional hazards regression model. Results A total of 6,983 patients were randomized worldwide with 3,495 randomized to receive an envelope and 3,488 randomized to the control. At 12 months, 25 major infections (0.7%) were observed in the envelope group and 42 major infections (1.2%) in the control group, resulting in a 40% reduction of major infections (HR: 0.60, 95% CI: 0.36–0.98, P = 0.04). Of 63 infections assayed, causative pathogens were identified in 36 infections whereas cultures were negative in 27 cases. Staphylococcus species (n = 22) were the predominate pathogens and a 53% reduction was observed with the use of TYRX (Figure 1). Moreover, there was only 1 CIED pocket infection with Staphylococcus species in the envelope group compared with 14 pocket infections in the control group. A comparison of timing of infection in the envelope group showed the presence of 11 endocarditis/bacteremia infections at 103 ± 84 days compared with 14 pocket infections presenting at 70 ± 78 days from the procedure. Conclusion In this large randomized trial, the use of the TYRX Envelope containing rifampin and minocycline resulted in a significant reduction of major CIED infections and was effective against staphylococcal species, which are the predominant cause of pocket infections. Disclosures All Authors: No reported Disclosures.