Back to Authors

Hernández‐Meneses, Marta

https://orcid.org/0000-0001-9991-1127

Mayo Clinic

Hospital Clínic de Barcelona

Citations 2

Cardiovascular implantable electronic device infections due to enterococcal species: Clinical features, management, and outcomes
Oh, Timothy S. , Le, Katherine, Sohail, M. Rizwan , Vikram, Holenarasipur R. , Hernández‐Meneses, Marta , Prutkin, Jordan M. , Greenspon, Arnold J. , Carrillo, Roger G. , Danik, Stephen B., Naber, Christoph, Blank, Elisabeth, Tseng, Chi‐Hong , Uslan, Daniel Z. , Peacock, James E. , Greenspon, Arnold J , Peacock, James E , Vikram, Holenarasipur R. , Sohail, M Rizwan , Oh, Timothy S., Baddour, Larry M. , Miró, José María

Pacing and Clinical Electrophysiology | August 19, 2019 | Volume: 42 | Issue: 10 | Pages: 1331-1339

10.1111/pace.13783 Get It

AbstractBackgroundEnterococcal cardiovascular implantable electronic device (CIED) infections are not well characterized.MethodsData from the Multicenter Electrophysiologic Device Infection Cohort, a prospective study of CIED infections, were used for descriptive analysis of adults with enterococcal CIED infections.ResultsOf 433 patients, 21 (4.8%) had enterococcal CIED infection. Median age was 71 years. Twelve patients (57%) had permanent pacemakers, five (24%) implantable cardioverter defibrillators, and four (19%) biventricular devices. Median time from last procedure to infection was 570 days. CIED‐related bloodstream infections occurred in three patients (14%) and 18 (86%) had infective endocarditis (IE), 14 (78%) of which were definite by the modified Duke criteria. IE cases were classified as follows: valvular IE, four; lead IE, eight; both valve and lead IE, six. Vegetations were demonstrated by transesophageal echocardiography in 17 patients (81%). Blood cultures were positive in 19/19 patients with confirmed results. The most common antimicrobial regimen was penicillin plus an aminoglycoside (33%). Antibiotics were given for a median of 43 days. Only 14 patients (67%) underwent device removal. There was one death during the index hospitalization with four additional deaths within 6 months (overall mortality 24%). There were no relapses.ConclusionsEnterococci caused 4.8% of CIED infections in our cohort. Based on the late onset after device placement or manipulation, most infections were likely hematogenous in origin. IE was the most common infection syndrome. Only 67% of patients underwent device removal. At 6 months follow‐up, no CIED infection relapses had occurred, but overall mortality was 24%.
Attempted salvage of infected cardiovascular implantable electronic devices: Are there clinical factors that predict success?
Peacock, James E. , Stafford, Jeanette M. , Le, Katherine, Sohail, M. Rizwan , Prutkin, Jordan M. , Danik, Stephan B., Vikram, Holenarasipur R. , Hernández‐Meneses, Marta , Blank, Elisabeth, Naber, Christoph, Carrillo, Roger G. , Greenspon, Arnold J. , Tseng, Chi‐Hong , Uslan, Daniel Z. , Vikram, Holenarasipur R. , Sohail, M Rizwan , Baddour, Larry M. , Miró, José María

Pacing and Clinical Electrophysiology | March 8, 2018 | Volume: 41 | Issue: 5 | Pages: 524-531

10.1111/pace.13319 Get It

AbstractBackgroundPublished guidelines mandate complete device removal in cases of cardiovascular implantable electronic device (CIED) infection. Clinical predictors of successful salvage of infected CIEDs have not been defined.MethodsData from the Multicenter Electrophysiologic Device Infection Collaboration, a prospective, observational, multinational cohort study of CIED infection, were used to investigate whether clinical predictors of successful salvage of infected devices could be identified.ResultsOf 433 adult patients with CIED infections, 306 (71%) underwent immediate device explantation. Medical management with device retention and antimicrobial therapy was initially attempted in 127 patients (29%). “Early failure” of attempted salvage occurred in 74 patients (58%) who subsequently underwent device explantation during the index hospitalization. The remaining 53 patients (42%) in the attempted salvage group retained their CIED. Twenty‐six (49%) had resolution of CIED infection (successful salvage group) whereas 27 patients (51%) experienced “late” salvage failure. Upon comparing the salvage failure group, early and late (N = 101), to the group experiencing successful salvage of an infected CIED (N = 26), no clinical or laboratory predictors of successful salvage were identified. However, by univariate analysis, coagulase‐negative staphylococci as infecting pathogens (P = 0.0439) and the presence of a lead vegetation (P = 0.024) were associated with overall failed salvage.ConclusionsIn patients with definite CIED infections, clinical and laboratory variables cannot predict successful device salvage. Until new data are forthcoming, device explantation should remain a mandatory and early management intervention in patients with CIED infection in keeping with existing expert guidelines unless medical contraindications exist or patients refuse device removal.