Back to Authors

Taepke, Robert T.

Mayo Clinic

Medtronic (United States)

Citations 2

Real World Performance of an Individualized Antitachycardia Pacing Algorithm
Jackson, Troy , Yee, Raymond, Taepke, Robert T., Cheng, Alan , Birgersdotter‐Green, Ulrika , Cha, Yong‐Mei , Taepke, Robert, Singh, Jagmeet P , Yee, Raymond

Journal of Cardiovascular Electrophysiology | June 5, 2025 | Volume: 36 | Issue: 8 | Pages: 1875-1885

10.1111/jce.16747 Get It

ABSTRACT Background A novel individualized antitachycardia pacing (IATP) algorithm using the post‐pacing interval for real‐time control has been introduced. Performance information is limited to a small safety and feasibility study with additional single‐center and case studies. A larger‐scale analysis is needed to better understand algorithm performance. Methods Deidentified remote monitoring transmissions from devices with the IATP therapy applied were randomly selected. Rhythms were classified and effects of the novel algorithm were assessed. For monomorphic ventricular tachycardias (MVTs) proportions of successful therapy, shock‐free episodes, and acceleration were calculated using generalized estimating equations to correct for multiple episodes and compute statistics of the algorithm's performance. Results There were 2259 MVT episodes in 336 patients. IATP succeeded in 87.1% of MVT episodes with 89.9% of MVT episodes ultimately free of shock therapy. Based on multivariate analysis, significant factors in therapy success were programming of at least the recommended number of sequences (90% at least recommended vs 73%, p = 0.00088) and female sex (95% for females vs 86%, p = 0.002). A trend to higher success was found for MVT with a cycle length of 320 ms or greater (90% vs. 83%, p = 0.10). The IATP accelerated 3.6% of MVT episodes. None of the available factors was significantly associated with acceleration in the multivariate analysis. Conclusions The IATP algorithm succeeded in a large proportion of MVT episodes and with low acceleration in patients randomly selected from remote monitoring transmissions. Using at least the recommended number of sequences had the strongest association with successful therapy.
Real-world performance of a fully automatic antitachycardia pacing algorithm
Jackson, Troy , Taepke, Robert T., Birgersdotter‐Green, Ulrika , M, Y, DeGroot, Paul, Cheng, Alan , Yee, Raymond , Singh, Jagmeet P

European Heart Journal | November 11, 2023 | Volume: 44 | Issue: Supplement_2 | Pages: No page available

10.1093/eurheartj/ehad655.660 Get It

Abstract Background Antitachycardia pacing (ATP) found in most implantable cardioverter defibrillators (ICDs) is an important therapy for painless termination of ventricular tachycardias (VT). In ICDs programmed to guideline-recommended detection and therapy settings typical ATP success rates are 50-70%.[1-3] The first closed-loop, automated ATP (AATP) algorithm, introduced in 2021, applies an S1 train derived from the detected VT, followed by an S2 derived initially from a refractory period estimator and then adjusted using analysis of the post-pacing interval if ATP fails. The termination efficacy of AATP in the real-world population is unknown. Purpose To assess the effectiveness AATP in a large real-world population. Methods A database of de-identified ICD transmissions from subjects in the United States, Australia, Canada, and New Zealand was queried for AATP treated episodes. ICDs were randomly sampled, biased toward ICDs with multiple treated VT episodes. For rhythms classified as monomorphic ventricular tachycardia, each AATP pulse train was reviewed for: rhythm at delivery, effect of ATP, and any non-capturing pulses. Acceleration was defined as a post-ATP decrease in MVT cycle length (VTCL) of at least 10% and at least 30ms. Acceleration to polymorphic VT or ventricular fibrillation (PVT/VF) was assessed. Rates of termination and acceleration were calculated for all MVT and dichotomized using a 320ms VTCL cutoff. The method of generalized estimating equations (GEE) was used to correct event rates for multiple episodes from a single patient. Results There were 2281 episodes of MVT in 340 patients; 63% of patients had 2 or more episodes. There were 724 episodes with initial VTCL <320ms and 1557 episodes with VTCL ≥320ms. The rate of termination of MVT by AATP was 78% for all VTCL [95% CI: 74%-81%]. In 300 patients (88%) AATP terminated at least one MVT. For MVT with VTCL ≥320ms the termination rate was 80% [95% CI: 75%-83%] and for VTCL <320ms the termination rate was 75% [95% CI: 69%-80%]. The rate of acceleration was 3.6% [95% CI: 2.7%-4.9%], with a 0.8% rate of acceleration to PVT/VF [95% CI: 0.4%-1.8%]. Acceleration led to shock therapy in 63% of accelerated episodes. All MVT accelerated to PVT/VF either spontaneously terminated (4/14) or were successfully converted by a single shock therapy (10/14). All accelerations that remained MVT were successfully treated by the device with either subsequent ATP (35%) or shock therapy (61%), or spontaneously terminated (4%). Conclusion In this large, real-world cohort analysis, automated ATP’s termination rate exceeded the typical success rate of burst ATP, particularly for MVT <320ms. Acceleration to PVT/VF was low and effective first-shock defibrillation was consistent. Subsequent ATP for accelerated MVT had incremental benefit, leading to successful termination one-third of the time. Additional data are currently being prospectively collected in a separate post-approval study.