Back to Authors

Krishnan, Prasad

https://orcid.org/0000-0002-6748-1182

Mayo Clinic

Mayo Clinic

Citations 4

Pediatric Epicardial Devices: Early and Midterm Outcomes
Griffeth, Elaine M. , Krishnan, Prasad , Dearani, Joseph A. , Ackerman, Michael J. , Wackel, Philip L. , Cannon, Bryan C. , Dearani, Joseph A. , Pahwa, Siddharth , Todd, Austin W.

World Journal for Pediatric and Congenital Heart Surgery | March 5, 2023 | Volume: 14 | Issue: 4 | Pages: 451-458

10.1177/21501351231157374 Get It

Background Lead performance is suboptimal in young patients and a main cause of device system failure. Our objective was to assess early and midterm outcomes after epicardial device implantation in a contemporary pediatric cohort. Methods A total of 116 consecutive pediatric patients underwent 137 epicardial device implantations from 2010 to 2019. Forty pacemakers and 97 implantable cardioverter defibrillators (ICDs) were implanted. Lead failure was defined as leads repaired, replaced, or abandoned due to fracture, dislodgement, or dysfunction. Freedom from device system failure was determined using Kaplan-Meier analysis. Results Mean age at implantation was 10 ± 5 years, 46 (34%) were younger than 8 years old, 41 (30%) had prior cardiac surgery, and 38 (28%) had prior devices. Main indications were acquired heart block (17/40 [43%]), sinus node dysfunction (14/40 [35%]), and congenital heart block (7/40 [18%]) for pacemakers, and hypertrophic cardiomyopathy (46/97 [47%]), long QT syndrome (31/97 [32%]), and ventricular arrhythmia (17/97 [18%]) for ICDs. There were no early deaths. Three-year freedom from device system failure was 80% (95% CI 73%, 88%) for all patients and 88% (95% CI 79%, 99%) for patients <8 years old. Device system failure causes included lead fracture (20/34 [59%]), lead dysfunction (5/34 [15%]), lead dislodgement (5/34 [15%]), infection (3/34 [9%]), and pericarditis (1/34 [3%]). Reintervention was required in 26/34 (76%) device system failures. Conclusions Epicardial device implantation is safe, shows acceptable midterm outcomes in children, and is an effective option in patients younger than 8 years old. Close device surveillance continues to be essential to detect lead failure early and ensure timely reintervention.
Twin Root Replacement in Congenital Heart Disease: Expert Technique
Krishnan, Prasad , Overman, David M. , Stephens, Elizabeth H. , Pochettino, Alberto , Dearani, Joseph A.

World Journal for Pediatric and Congenital Heart Surgery | October 1, 2021 | Volume: 12 | Issue: 5 | Pages: 649-653

10.1177/21501351211035787 Get It

In adult congenital heart disease, there are situations that require both the aortic and pulmonary roots to be replaced at the time of a reoperation. This commonly involves the replacement of a previously implanted right ventricle-pulmonary artery conduit in a patient with late aortic root dilation and/or neo-aortic valve dysfunction following the Ross procedure. Similar scenarios are encountered in patients having undergone previous repair of conotruncal anomalies such as truncus arteriosus and tetralogy of Fallot with pulmonary atresia. We describe our standardized technique for twin root replacement.
What Factors Should Be Considered to Improve Outcome of Mechanical Mitral Valve Replacement in Children?
Elsisy, Mohamed F. , Ashikhmina, Elena, Dorn, Charlotte S. Van , Stephens, Elizabeth H. , Krishnan, Prasad , Anderson, Jason H. , Van Dorn, Charlotte S, Dearani, Joseph A. , Krishnan, Prasad, Taggart, Nathaniel W.

World Journal for Pediatric and Congenital Heart Surgery | May 4, 2021 | Volume: 12 | Issue: 3 | Pages: 367-374

10.1177/2150135121994084 Get It

Objective: To identify risk factors for pediatric mechanical mitral valve replacement (mMVR) to improve management in this challenging population. Methods: From 1993 to 2019, 93 children underwent 119 mMVR operations (median age, 8.8 years [interquartile range [IQR]: 2.1-13.3], 54.6% females) at our institution. Twenty-six (21.8%) patients underwent mMVR at ≤2 years and 93 (78.2%) patients underwent mMVR at >2 years. Median follow-up duration was 7.6 years [IQR: 3.2-12.4]. Results: Early mortality was 9.7%, but decreased with time and was 0% in the most recent era (13.9% from 1993 to 2000, 7.3% from 2001 to 2010, 0% from 2011 to 2019, P = .04). It was higher in patients ≤2 years compared to patients >2 years (26.9% vs 2.2%, P < .01). On multivariable analysis for mitral valve reoperation, valve size <23 mm was significant with a hazard ratio of 5.38 (4.87-19.47, P = .01);. Perioperative stroke occurred in 1% and permanent pacemaker was necessary in 12%. Freedom from mitral valve reoperation was higher in patients >2 years and those with a prosthesis ≥23 mm. Median time to reoperation was 7 years (IQR: 4.5-9.1) in patients >2 years and 3.5 years (IQR: 0.6-7.1) in patients ≤2 years ( P = .0511), but was similar between prosthesis sizes ( P = .6). During follow-up period (median 7.6 years [IQR: 3.2-12.4], stroke occurred in 10%, prosthetic valve thrombosis requiring reoperation in 4%, endocarditis in 3%, and bleeding in 1%. Conclusion: Early and late outcomes of mMVR in children are improved when performed at age >2 years and with prosthesis size ≥23 mm. These factors should be considered in the timing of mMVR.
Use of angled hegar dialator for antegrade sizing of the right ventricular outflow tract in tetralogy of Fallot
Krishnan, Prasad

Journal of Cardiac Surgery | February 24, 2021 | Volume: 36 | Issue: 4 | Pages: 1539-1540

10.1111/jocs.15450 Get It