Back to Authors

Khalil, Fouad

0000-0002-8241-4324

Mayo Clinic

University of Nebraska Medical Center

Citations 9

Interplay of Pulmonary Hypertension and the Effects of Panel‐Reactive Antibodies on Outcomes of Heart Transplant Recipients Bridged With Left Ventricular Assist Device
Khalil, Fouad , Asleh, Rabea , Mawer, Scott, Kim, Kathryn M., Regev, Ohad , Briasoulis, Alexandros, Alnsasra, Hilmi, Khalil, Fouad , Briasoulis, Alexandros , Alnsasra, Hilmi , Asleh, Rabea , Briasoulis, Αlexandros

Journal of the American Heart Association | March 4, 2026 | Volume: 15 | Issue: 6 | Pages: No page available

10.1161/jaha.125.044572 Get It

Background Pulmonary hypertension (PH) and sensitization adversely affect heart transplant outcomes. Although left ventricular assist devices may reduce PH, they can increase sensitization. We examined the impact of sensitization on heart transplant outcomes in left ventricular assist device‐bridged patients and whether precapillary PH modifies this effect. Methods Adults bridged to heart transplant with an left ventricular assist device between 2005 and 2020 were identified from the United Network for Organ Sharing database. Patients with available panel‐reactive antibody (PRA) and hemodynamic data were included. Associations between PRA and survival and treated rejection were analyzed. Results Among 2469 patients, 1053 had precapillary PH (pulmonary vascular resistance [PVR] >2 Wood units [WU]) and 1416 had PVR ≤2 WU. Elevated PRA (>10%) occurred in 566 patients (24.8% with PVR >2 WU; 21.5% with PVR ≤2 WU). Overall, PRA >10% was associated with increased mortality (adjusted hazard ratio [aHR], 1.28 [95% CI, 1.04–1.58], P =0.022), driven by patients with PVR >2 WU (aHR, 1.82 [95% CI, 1.34–2.50], P <0.001), with no association in those with PVR ≤2 WU (aHR, 0.99 [95% CI, 0.47–1.32], P =0.92). PRA >10% was also associated with treated rejection overall (adjusted odds ratio [aOR], 1.41 [95% CI, 1.09–1.82], P =0.008), confined to the PVR >2 WU group (aOR, 1.87 [95% CI, 1.26–2.76], P =0.002) and absent in the PVR ≤2 WU group (aOR, 1.13 [95% CI, 0.80–1.59], P =0.49). Conclusions Elevated PRA predicts worse outcomes in LVAD‐bridged transplant recepients with precapillary PH, but not in those without precapillary PH.
Ventricular arrhythmias in patients with prior aortic valve intervention: Characteristics, ablation and outcomes
Khalil, Fouad , Ahmad, Ali , Siontis, Konstantinos C. , Mulpuru, Siva K. , Munoz, Freddy Del‐Carpio , Cha, Yong‐Mei , Friedman, Paul A. , Munger, Thomas M. , Asirvatham, Samuel J. , Killu, Ammar M. , Siontis, Konstantinos C , Mulpuru, Siva K , Del-Carpio Munoz, Freddy , Cha, Yong-Mei , Friedman, Paul A , Munger, Thomas, Asirvatham, Samuel J , Killu, Ammar M , Khalil, Fouad , Toya, Takumi

Journal of Cardiovascular Electrophysiology | March 30, 2023 | Volume: 34 | Issue: 5 | Pages: 1206-1215

10.1111/jce.15896 Get It

AbstractIntroductionData regarding ventricular tachycardia (VT) or premature ventricular complex (PVC) ablation in patients with aortic valve (AV) intervention (AVI) is limited. Catheter ablation (CA) can be challenging given perivalvular substrate in the setting of prosthetic valves. We sought to investigate the characteristics, safety, and outcomes of CA in patients with prior AVI and ventricular arrhythmias (VA).MethodsWe identified consecutive patients with prior AVI (replacement or repair) who underwent CA for VT or PVC between 2013 and 2018. We investigated the mechanism of arrhythmia, ablation approach, perioperative complications, and outcomes.ResultsWe included 34 patients (88% men, mean age 64 ± 10.4 years, left ventricular (LV) ejection fraction 35.2 ± 15.0%) with prior AVI who underwent CA (22 VT; 12 PVC). LV access was obtained through trans‐septal approach in all patients except one patient who had percutaneous transapical access. One patient had combined retrograde aortic and trans‐septal approach. Scar‐related reentry was the dominant mechanism of induced VTs. Two patients had bundle branch reentry VTs. In the VT group, substrate mapping demonstrated heterogeneous scar that involved the peri‐AV area in 95%. Despite that, the site of successful ablation included the periaortic region only in 6 (27%) patients. In the PVC group, signal abnormalities consistent with scar in the periaortic area were noted in 4 (33%) patients. In 8 (67%) patients, the successful site of ablation was unrelated to the periaortic area. No procedure‐related complications occurred. The survival and recurrence‐free survival rate at 1 year tended to be lower in VT group than in PVC group (p = .06 and p = .05, respectively) with a 1‐year recurrence‐free survival rate of 52.8% and 91.7%, respectively. No arrhythmia‐related death was documented on long‐term follow‐up.ConclusionCA of VAs can be performed safely and effectively in patients with prior AVI.
Vascular Function in Continuous Flow LVADs: Implications for Clinical Practice
Khalil, Fouad , Asleh, Rabea , Perue, Radha Kanneganti , Weinstein, Jean-Marc, Solomon, Adam , Betesh-Abay, Batya , Briasoulis, Αlexandros , Alnsasra, Hilmi , Briasoulis, Alexandros , Khalil, Fouad , Asleh, Rabea

Biomedicines | March 2, 2023 | Volume: 11 | Issue: 3 | Pages: 757

10.3390/biomedicines11030757 Get It

Left ventricular assist devices (LVADs) have been increasingly used in patients with advanced heart failure, either as a destination therapy or as a bridge to heart transplant. Continuous flow (CF) LVADs have revolutionized advanced heart failure treatment. However, significant vascular pathology and complications have been linked to their use. While the newer CF-LVAD generations have led to a reduction in some vascular complications such as stroke, no major improvement was noticed in the rate of other vascular complications such as gastrointestinal bleeding. This review attempts to provide a comprehensive summary of the effects of CF-LVAD on vasculature, including pathophysiology, clinical implications, and future directions.
Response to letter to the editor regarding “Characteristics and outcomes of ventricular tachycardia and premature ventricular contractions ablation in patients with prior mitral valve surgery”
Khalil, Fouad , Killu, Ammar M. , Khalil, Fouad

Journal of Cardiovascular Electrophysiology | April 19, 2022 | Volume: 33 | Issue: 6 | Pages: 1347-1348

10.1111/jce.15503 Get It

Response to Letter to the Editor regarding ‘Characteristics and outcomes of ventricular tachycardia and premature ventricular contractions ablation in patients with prior mitral valve surgery’
Khalil, Fouad , Killu, Ammar M. , Khalil, Fouad

No container title available | April 6, 2022 | Volume: No volume available | Issue: No issue available | Pages: No page available

10.22541/au.164922306.68091730/v1 Get It

We would like to thank the authors for their letter and interest in our manuscript. We appreciate their valuable comments. The authors have raised the following important points: 1. The heterogenicity of our cohort with mitral valve surgery (MVS) 2. Elucidating the characteristics and causes of ventricular arrhythmias (VA) in patients with primary versus secondary mitral disease as well as in those with ischemic versus non-ischemic heart disease 3. The paucity of cardiac magnetic resonance imaging (MRI) as a limitation of the study 4. The need for careful evaluation of patients prior to ablation since most arrhythmias did not originate from the perimitral area.
Characteristics and outcomes of ventricular tachycardia and premature ventricular contractions ablation in patients with prior mitral valve surgery
Khalil, Fouad , Madhavan, Malini , Ahmad, Ali , Mulpuru, Siva K. , Siontis, Konstantinos C. , Deshmukh, Abhishek , Cha, Yong‐Mei , Friedman, Paul A. , Munger, Thomas M. , Asirvatham, Samuel J. , Killu, Ammar M. , Madhavan, Malini , Kapa, Suraj , Mulpuru, Siva K , Siontis, Konstantinos C , Deshmukh, Abhishek J , Friedman, Paul A , Munger, Thomas, Asirvatham, Samuel J , Killu, Ammar M , Khalil, Fouad , Toya, Takumi , Badawy, Mohamed, Kapa, Suraj , DeSimone, Christopher V.

Journal of Cardiovascular Electrophysiology | December 15, 2021 | Volume: 33 | Issue: 2 | Pages: 274-283

10.1111/jce.15331 Get It

AbstractBackgroundData regarding ventricular tachycardia (VT) or premature ventricular complex (PVC) ablation following mitral valve surgery (MVS) is limited. Catheter ablation (CA) can be challenging given perivalvular substrate in the setting of mitral annuloplasty or prosthetic valves.ObjectiveTo investigate the characteristics, safety, and outcomes of radiofrequency CA in patients with prior MVS and ventricular arrhythmias (VA).MethodsWe identified consecutive patients with prior MVS who underwent CA for VT or PVC between January 2013 and December 2018. We investigated the mechanism of arrhythmia, ablation approach, peri‐operative complications, and outcomes.ResultsIn our cohort, 31 patients (77% men, mean age 62.3 ± 10.8 years, left ventricular ejection fraction 39.2 ± 13.9%) with prior MVS underwent CA (16 VT; 15 PVC). Access to the left ventricle was via transseptal approach in 17 patients, and a retrograde aortic approach was used in 13 patients. A combined transseptal and retrograde aortic approach was used in one patient, and a percutaneous epicardial approach was combined with trans‐septal approach in one patient. Heterogenous scar regions were present in 94% of VT patients and scar‐related reentry was the dominant mechanism of VT. Forty‐seven percent of PVC patients had abnormal substrate at the site targeted for ablation. Clinical VA substrates involved the peri‐mitral area in six patients with VT and five patients with PVC ablation. No procedure‐related complications were reported. The overall recurrence‐free rate at 1‐year was 72.2%; 67% in the VT group and 78% in the PVC group. No arrhythmia‐related death was documented on long‐term follow‐up.ConclusionCA of VAs can be performed safely and effectively in patients with MVS.
Characteristics and Outcomes of Ventricular Tachycardia and Premature Ventricular Contractions Ablation in Patients with Prior Mitral Valve Surgery
Khalil, Fouad , Madhavan, Malini , Badawy, Mohammed, Kapa, Suraj , Mulpuru, Siva K. , Siontis, Konstantinos C. , DeSimone, Christopher V. , Deshmukh, Abhishek , Cha, Young-mei, Friedman, Paul A. , Munger, Thomas M. , Killu, Ammar M. , Khalil, Fouad , Kapa, Suraj , DeSimone, Christopher V , Toya, Takumi , Badawy, Mohammed, Asirvatham, Samuel J.

No container title available | July 2, 2021 | Volume: No volume available | Issue: No issue available | Pages: No page available

10.22541/au.162524921.19356960/v1 Get It

Background: Data regarding ventricular tachycardia (VT) or premature ventricular complex (PVC) ablation following MVS is limited.) CA can be challenging given perivalvular substrate in the setting of mitral annuloplasty or prosthetic valves. Objective: To investigate the characteristics, safety, and outcomes of radiofrequency catheter ablation (CA) in patients with prior mitral valve surgery (MVS) and ventricular arrhythmias (VA). Methods: We identified consecutive patients with prior MVS who underwent CA for VT or PVC between January 2013- December 2018. We investigated the mechanism of arrhythmia, ablation approach, peri-operative complications, and outcomes. Results: In our cohort of 31 patients (77% men, mean age 62.3±10.8 years, left ventricular ejection fraction 39.2±13.9%) with prior MVS underwent CA (16 VT; 15 PVC). Access to the left ventricle was via transseptal approach in 17 patients, and a retrograde aortic approach was used in 13 patients. A combined transseptal and retrograde aortic approach was used in one patient, and a percutaneous epicardial approach was combined with trans-septal approach in 1patient. Heterogenous scar regions were present in 94% of VT patients and scar-related reentry was the dominant mechanism of VT. Clinical VA substrates involved the peri-mitral area in 6 patients with VT and 5 patients with PVC ablation. No procedure-related complications were reported. The overall recurrence-free rate at 1-year was 72.2%; 67% in the VT group and 78% in the PVC group. No arrhythmia-related death was documented on long-term follow-up. Conclusion: CA of VAs can be performed safely and effectively in patients with MVS
Utilization and procedural adverse outcomes associated with Watchman device implantation
Khalil, Fouad , Arora, Shilpkumar , Killu, Ammar M. , Egbe, Alexander C. , Kapa, Suraj , Mulpuru, Siva K. , Mohamad, Alkhouli, Friedman, Paul A. , Holmes, David R. , Deshmukh, Abhishek , Mulpuru, Siva, Khalil, Fouad , Kapa, Suraj , Tripathi, Byomesh , DeSimone, Christopher V. , Noseworthy, Peter A. , Gersh, Bernard J.

EP Europace | August 9, 2020 | Volume: 23 | Issue: 2 | Pages: 247-253

10.1093/europace/euaa219 Get It

AbstractAims The Food and Drug Administration (FDA) approval of the Watchman device [percutaneous left atrial appendage occlusion (LAAO)] has resulted in the widespread use of this procedure in many centres across the USA. We sought to estimate the nationwide utilization and frequency of adverse outcomes associated with Watchman device implantation. The objective of this study was to evaluate the Watchman device implantation peri-procedural complications and comparison of the results with the previous studies.Methods and results The National Inpatient Sample (NIS) was queried for all hospitalizations with a primary diagnosis of atrial fibrillation or atrial flutter during the year 2016 with percutaneous LAAO during the same admission (ICD-10 code—02L73DK). The frequency of peri-procedural complications, including mortality, procedure-related stroke, major bleeding requiring blood transfusion, and pericardial effusion, was assessed. We compared the complication rates with the published randomized controlled trials and the European Watchman registry. An estimated 5175 LAAO procedures were performed in 2016. The majority of procedures was performed in males (59.1%), age ≥75 years (58.7%), and White (83.1%). The overall complication rate was 1.9%. The in-hospital mortality was 0.29%. Pericardial effusion requiring pericardiocentesis was the most frequent complication (0.68%). Bleeding requiring transfusion was noted in 0.1% of device implants. The rates of post-procedure stroke and systemic embolism were 0% and 0.29%, respectively.Conclusion Percutaneous LAAO with the Watchman device in the USA is associated with low in-hospital complications and a similar safety profile to a recently published EWOLUTION cohort. The complication rates were lower than those reported in the major randomized clinical trials (RCTs). We report the frequency of peri-procedural complications of the LAAO using the Watchman device from the NIS database. We also compare the frequency of peri-procedural complications with the previously published RCTs and EWOLUTION cohort. Our findings are in concordance with findings from EWOLUTION cohort and compare favourably with RCTs.
Left ventricular pacing induced polymorphic ventricular tachycardia via the adaptive left ventricle pacing algorithm
Khalil, Fouad , Munoz, Freddy Del‐Carpio , Deshmukh, Abhishek , Killu, Ammar M. , Del-Carpio Munoz, Freddy , Khalil, Fouad

Clinical Case Reports | May 27, 2020 | Volume: 8 | Issue: 8 | Pages: 1511-1516

10.1002/ccr3.2940 Get It

AbstractProviders should be aware of the possibility of cardiac resynchronization therapy‐related proarrhythmia which could be life‐threatening. His‐bundle pacing may serve as an alternative, more physiological, option in the management as it preserves the normal sequence of depolarization from the septum to the lateral wall, and from endocardium to epicardium.