Department of Cardiovascular Medicine, Mayo Clinic, Rochester (K.Q.A., J.A.T., I.U.H., A.W., H.N., A.B., S.Y., R.W., F.E., N.Y.T., F.D.-C.M., S.A., C.V.D.).
Citations 6
Ventricular Fibrillation Mapping in a Large-Animal Model Using Dual Mechanical Circulatory Support: Electroanatomic Substrate Preservation Without Ischemic Changes
Circulation: Arrhythmia and Electrophysiology | September 18, 2026 | Volume: No volume available | Issue: No issue available | Pages: No page available
BACKGROUND: Ventricular fibrillation (VF) remains a leading cause of sudden cardiac death with an incompletely characterized electrophysiological substrate. Traditional large-animal VF models are limited by hemodynamic collapse and myocardial ischemia. This study establishes a reproducible swine model using dual mechanical circulatory devices to enable high-density electroanatomic mapping under nonischemic conditions. METHODS: Five Yorkshire swine (55–65 kg) underwent sustained VF supported by venoarterial extracorporeal membrane oxygenation (2.5–3.0 L/min) and percutaneous left ventricular unloading (Impella CP, P-2–P-4). High-density electroanatomic mapping using CARTO 7 was performed at baseline and after defibrillation. Bipolar voltage was acquired from 7 predefined ventricular regions (21 measurements per animal per time point; n=210 paired observations). Unipolar voltage mapping and continuous surface ECG monitoring were used to assess acute ischemic injury. Systemic perfusion was maintained at systolic arterial pressure ≥80 mm Hg. Linear mixed-effects modeling was used to analyze voltage changes from pre-VF to post-VF. RESULTS: Sustained VF (10±1 minutes) was reproducibly induced and maintained with consistent hemodynamics (systolic arterial pressure, 90±5 mm Hg; extracorporeal membrane oxygenation flow, 2.5±0.5 L/min). All animals were successfully defibrillated. High-density mapping was feasible in all experiments (1000±300 points per chamber). Bipolar voltage showed no change from pre-VF (5.86±2.56 mV) to post-VF (6.53±2.22 mV; mean difference, 0.67 mV [95% CI, –0.31 to 1.65]; P =0.15). Both left ( P =0.17) and right ventricles ( P =0.08) demonstrated voltage preservation. Regional analysis showed no significant changes (all P >0.05); post-VF voltages remained above viability thresholds (>1.5 mV). Unipolar voltage maps recovered toward baseline, with no ECG injury pattern identified after defibrillation. CONCLUSIONS: Dual mechanical circulatory support with venoarterial extracorporeal membrane oxygenation and Impella CP enables reproducible, high-fidelity electroanatomic mapping and preserves myocardial substrate after sustained VF in a large-animal model. This platform overcomes key technical barriers in VF research, providing a nonischemic foundation for future mechanistic and translational studies.
Lead Extraction and Outcomes in Frail Patients With Cardiac Implantable Electronic Device Infections in the United States
ABSTRACT Introduction Frailty is increasingly recognized as an important determinant of outcomes in cardiovascular disease, yet its population‐level impact among patients hospitalized with cardiac implantable electronic device (CIED) infections remains incompletely defined. We examined the prevalence of frailty and its association with clinical outcomes and utilization of transvenous lead removal (TLR) in a contemporary national cohort. Methods and Results We analyzed the National Readmissions Database from 2016–2021 to identify adults hospitalized for CIED infections. Frailty was defined using the Johns Hopkins adjusted clinical groups frailty‐defining diagnoses. Of 288,402 patients hospitalized with CIED infections, 25.1% were classified as frail. Frail patients experienced significantly higher in‐hospital mortality (10.8% vs. 4.6%), 30‐day mortality (9.2% vs. 5.5%), complications, longer length of stay, lower rates of discharge home, and higher 30‐day readmissions compared with non‐frail patients (all p < 0.01). TLR was performed less frequently in frail patients (10.8% vs. 13.4%; adjusted odds ratio [aOR] 0.80, 95% CI 0.76–0.83). On adjusted analyses, TLR was independently associated with lower in‐hospital mortality, 30‐day mortality, and 30‐day readmissions in both frail and non‐frail patients. Conclusion Among patients hospitalized with CIED infections, TLR was independently associated with lower mortality and readmissions in both frail and non‐frail patients, despite lower utilization in frail individuals. Frailty was common (25.1%) and independently associated with significantly worse outcomes. These findings highlight important associations between frailty, treatment patterns, and outcomes that warrant prospective evaluation.
Ventricular Tachycardia Ablation in LVAD Recipients: What We Know, What We Still Don't
ABSTRACT Background Valve‐in‐valve transcatheter aortic valve replacement (ViV‐TAVR) is increasingly used to treat structural valve degeneration. Permanent pacemaker implantation (PPI) following TAVR is associated with increased morbidity and mortality, yet predictors specific to ViV‐TAVR remain poorly defined. Objective To identify clinical and procedural predictors of PPI in patients undergoing ViV‐TAVR. Methods We conducted a retrospective observational study of consecutive ViV‐TAVR cases at the Mayo Clinic from 2012 to 2022. Clinical, ECG, procedural data and fluoroscopic measurements were analyzed, and propensity score matching was used to adjust for confounding. Predictors of PPI were identified using multivariable logistic regression. Results Among 261 patients, 24 (9.2%) underwent PPI. Balloon‐expandable valves were used in 66.7% and self‐expanding valves in 33.3%. Predictors of PPI included Preprocedural bifascicular block (OR 12.15, 95% CI: 2.52–68.89, p = 0.003), greater septal implantation depth (OR 1.29, 95% CI: 1.04–1.65, p = 0.019), and post‐procedural new left (OR 23.56, 95% CI: 4.91–48.52, p = 0.0004) and right bundle branch blocks (OR 24.4, 95% CI: 3.82–30.51, p = 0.001). Aortic regurgitation as the mechanism of prosthetic valve failure was associated with reduced PPI odds (OR 0.28, 95% CI: 0.10–0.76, p = 0.014). Pacing requirement—defined as > 90% ventricular pacing—increased from 25% at 3 months to 56.25% at 12 months. At a median follow‐up of 962.5 days (IQR 481.5–1555.3), adjusted mortality was significantly higher in the PPI group (aOR 9.4, 95% CI: 1.9–60.4, p = 0.028). Conclusion Bifascicular block, greater septal depth, and new bundle branch blocks predict PPI post‐ViV‐TAVR, while aortic regurgitation appears protective. Risk stratification and procedural planning are critical.
Catheter Ablation for Ventricular Tachycardia in Ischemic Cardiomyopathy: A Meta‐Analysis With Reconstructed Time‐to‐Event and Trial Sequential Analysis
ABSTRACT Background Ventricular tachycardia (VT) is a major contributor to sudden cardiac death among patients with ischemic heart disease (IHD). While catheter ablation reduces the arrhythmic burden, the impact on long‐term outcomes remains uncertain. We assess the efficacy of catheter ablation in patients with IHD. Methods We performed a meta‐analysis by systematically searching electronic databases from inception to April 2025. Pairwise, reconstructed time‐to‐event data meta‐analyses and Trial Sequential analyses were conducted. Results A total of seven studies (1192 participants) were included. Among patients with IHD with ICD, VT ablation was associated with a significant reduction in ICD shocks (RR = 0.50, 95% CI = [0.34–0.74]), a trend toward reduced VT storm (RR = 0.64, 95% CI = [0.40–1.04], p = 0.07), and lower rates of cardiovascular hospitalization (RR = 0.73, 95% CI = [0.53–1.01], p = 0.06) compared to ICD alone. However, no significant differences were observed when compared to patients receiving ICD plus antiarrhythmic drugs (AADs). VT ablation showed no significant impact on mortality or VT/VF recurrence compared to either ICD alone or ICD with AADs. Reconstructed Kaplan–Meier analysis for all‐cause mortality showed no significant difference between VT ablation and AAD + ICD. Trial Sequential Analysis provided conclusive evidence for VT/VF recurrence, while further data is required for other outcomes. Conclusion Among patients with IHD with ICD, VT ablation reduces ICD shocks, VT storm, and cardiovascular hospitalizations compared to ICD‐only therapy, but offers no significant advantage over ICD combined with AADs. VT ablation does not impact overall mortality or the recurrence of VT/VF. Trial sequential analysis confirmed conclusive evidence for VT/VF recurrence, while additional data is needed for other outcomes.
Predictors of Permanent Pacemaker Implantation Following Valve-In-Valve Transcatheter Aortic Valve Replacement
Background Valve-in-valve transcatheter aortic valve replacement (ViV-TAVR) is increasingly used to treat structural valve degeneration. Permanent pacemaker implantation (PPI) following TAVR is associated with increased morbidity and mortality, yet predictors specific to ViV-TAVR remain poorly defined. Objective To identify clinical and procedural predictors of PPI in patients undergoing ViV-TAVR. Methods We conducted a retrospective observational study of consecutive ViV-TAVR cases at the Mayo Clinic from 2012 to 2022. Clinical, ECG, procedural data and fluoroscopic measurements were analyzed, and propensity score matching was used to adjust for confounding. Predictors of PPI were identified using multivariable logistic regression. Results Among 261 patients, 24 (9.2%) required PPI. Balloon-expandable valves were used in 66.7% and self-expanding valves in 33.3%. Predictors of PPI included pre-procedural bifascicular block (OR 12.15, 95% CI: 2.52–68.89, p=0.003), greater septal implantation depth (OR 1.29, 95% CI: 1.04–1.65, p=0.019), and post-procedural new left (OR 23.56, 95% CI: 4.91–48.52, p=0.0004) and right bundle branch blocks (OR 24.4, 95% CI: 3.82–30.51, p=0.001). Aortic regurgitation as the mechanism of prosthetic valve failure was associated with reduced PPI odds (OR 0.28, 95% CI: 0.10–0.76, p=0.014). Pacing requirement—defined as >90% ventricular pacing—increased from 25% at 3 months to 56.25% at 12 months. At a median follow-up of 962.5 days (IQR 481.5–1555.3), adjusted mortality was significantly higher in the PPI group (aOR 9.4, 95% CI: 1.9–60.4, p=0.028). Conclusion Bifascicular block, greater septal depth, and new bundle branch blocks predict PPI post-ViV-TAVR, while aortic regurgitation appears protective. Risk stratification and procedural planning are critical.