Department of Cardiovascular Medicine, Mayo Clinic, Rochester (K.Q.A., J.A.T., I.U.H., A.W., H.N., A.B., S.Y., R.W., F.E., N.Y.T., F.D.-C.M., S.A., C.V.D.).
Citations 6
Ventricular Fibrillation Mapping in a Large-Animal Model Using Dual Mechanical Circulatory Support: Electroanatomic Substrate Preservation Without Ischemic Changes
Circulation: Arrhythmia and Electrophysiology | September 18, 2026 | Volume: No volume available | Issue: No issue available | Pages: No page available
BACKGROUND: Ventricular fibrillation (VF) remains a leading cause of sudden cardiac death with an incompletely characterized electrophysiological substrate. Traditional large-animal VF models are limited by hemodynamic collapse and myocardial ischemia. This study establishes a reproducible swine model using dual mechanical circulatory devices to enable high-density electroanatomic mapping under nonischemic conditions. METHODS: Five Yorkshire swine (55–65 kg) underwent sustained VF supported by venoarterial extracorporeal membrane oxygenation (2.5–3.0 L/min) and percutaneous left ventricular unloading (Impella CP, P-2–P-4). High-density electroanatomic mapping using CARTO 7 was performed at baseline and after defibrillation. Bipolar voltage was acquired from 7 predefined ventricular regions (21 measurements per animal per time point; n=210 paired observations). Unipolar voltage mapping and continuous surface ECG monitoring were used to assess acute ischemic injury. Systemic perfusion was maintained at systolic arterial pressure ≥80 mm Hg. Linear mixed-effects modeling was used to analyze voltage changes from pre-VF to post-VF. RESULTS: Sustained VF (10±1 minutes) was reproducibly induced and maintained with consistent hemodynamics (systolic arterial pressure, 90±5 mm Hg; extracorporeal membrane oxygenation flow, 2.5±0.5 L/min). All animals were successfully defibrillated. High-density mapping was feasible in all experiments (1000±300 points per chamber). Bipolar voltage showed no change from pre-VF (5.86±2.56 mV) to post-VF (6.53±2.22 mV; mean difference, 0.67 mV [95% CI, –0.31 to 1.65]; P =0.15). Both left ( P =0.17) and right ventricles ( P =0.08) demonstrated voltage preservation. Regional analysis showed no significant changes (all P >0.05); post-VF voltages remained above viability thresholds (>1.5 mV). Unipolar voltage maps recovered toward baseline, with no ECG injury pattern identified after defibrillation. CONCLUSIONS: Dual mechanical circulatory support with venoarterial extracorporeal membrane oxygenation and Impella CP enables reproducible, high-fidelity electroanatomic mapping and preserves myocardial substrate after sustained VF in a large-animal model. This platform overcomes key technical barriers in VF research, providing a nonischemic foundation for future mechanistic and translational studies.
Local Calcium Chloride Infusion Enhances Acute and Chronic Efficacy of Ventricular Pulsed‐Field Ablation
ABSTRACT Background Pulsed‐field ablation (PFA) offers myocardial selectivity with minimal thermal injury, but depth for ventricular lesions may be insufficient or heterogeneous at clinically tolerable field strengths. Calcium electroporation—local calcium chloride (CaCl₂) infusion after PFA—may amplify electroporation‐mediated cell death while maintaining low energy settings. Objective To determine whether immediate post‐PFA CaCl₂ infusion enhances acute and chronic ventricular lesion formation in vivo. Methods Nine swine underwent focal ventricular PFA (750–1000 V, biphasic, 20 μs × 50 pulses, 200 ms interpulse) via an irrigated focal catheter and benchtop electroporator. Immediately post‐PFA, lesions were randomized to saline, 0.2 g Ca, or 0.4 g Ca infused locally through the catheter tip. Acute hearts were explanted for TTC analysis; surviving animals were studied at 7 days for chronic lesion geometry. Results Among 41 acute lesions (17 control, 12 Ca 0.2 g, 12 Ca 0.4 g), Ca 0.4 g increased dark‐zone depth (3.5 ± 1.4 vs. 2.3 ± 0.8 mm; p = 0.038) and pale‐zone depth (2.6 ± 1.3 vs. 1.3 ± 0.8 mm; p = 0.011) versus control. At 7 days ( n = 33 lesions), Ca 0.4 g produced larger scars than control (width 11.6 ± 2.1 vs. 10.0 ± 1.9 mm; p = 0.027; depth 4.2 ± 1 vs. 3.0 ± 0.8 mm; p < 0.001; volume 193.6.4 ± 82.3 vs. 109.4 ± 48.2 mm³; p = 0.001). Conclusions Local CaCl₂ infusion after ventricular PFA significantly augments acute electroporation effect and chronic lesion size at low output, supporting facilitated PFA as a strategy for deeper, more durable ventricular ablation.
Effects of In Vivo Contact Force on Pulsed‐Field Ablation Efficacy in Porcine Ventricles
ABSTRACT Background Pulsed‐field ablation (PFA) is an innovative non‐thermal method for arrhythmia treatment. The efficacy of various PFA configurations in relation to contact force (CF) has not been well‐studied in vivo. Objectives This study evaluated the effect of CF on acute bipolar PFA lesions in both a vegetal and an in vivo porcine heart model. Methods Bipolar PFA (500 V, 20 μs for 50 pulses) was applied to eight porcine ventricles, with CF categorized as standard (5–15 g), high (16–30 g), or very high (> 30 g) using the CARTO 3 system. PFA lesions were assessed by gross pathology, histology, and post‐ablation voltage amplitude. Additionally, a vegetal model using oscillating russet potatoes replicated the motion of a beating heart to compare lesion parameters under dynamic conditions and various PFA configurations (monopolar vs. bipolar). Results A total of 61 in vivo bipolar PFA lesions across all groups were analyzed. No significant differences in lesion surface diameter, depth, or volume were found among CF groups. In the vegetal model, monopolar setting had a better correlation between CF and lesion depth compared to bipolar setting. In addition, oscillations and catheter position (perpendicular or parallel) significantly affected lesion dimensions. Conclusion Increasing CF has a minimal effect on the size of acute bipolar PFA lesions in the porcine ventricle, suggesting that, for bipolar PFA, adequate CF is more critical than its intensity in a beating heart. For monopolar PFA, greater CF can impact lesion depth.
Local calcium chloride infusion after pulsed field ablation enhances acute efficacy of cardiac electroporation
AbstractIntroductionPulsed field ablation (PFA) has emerged as an innovative therapy for cardiac arrhythmias. Drawing parallels with PFA's application in solid tumors, calcium chloride (CaCl2) as an adjuvant therapy, known as calcium electroporation, may amplify PFA's apoptotic effects. We propose that PFA in the atrium could enhance calcium uptake through PFA‐created pores, thereby increasing ablation efficacy even at reduced power levels by exploiting PFA's permeabilization effects.MethodsWe conducted in vivo ablations on the atria of seven pigs using low PFA power (250 V, 20 μs for 50 pulses at 200 ms intervals). Post‐PFA, we randomly administered an infusion of either 200 mg/2 ml CaCl2 (calcium group) or saline (control) directly to the ablation site via the catheter tip. We evaluated reduction in electrogram voltage amplitude, electrocardiography (ECG) parameters, ablation lesion parameters, and histology after PFA.ResultsNineteen lesions from control and calcium groups were examined. Control lesions showed no voltage decrease post‐PFA, whereas calcium‐treated lesions exhibited a significant voltage reduction. Gross pathology indicated marked differences in maximum lesion surface diameter, depth, and volume between the lesion groups. Histologically, calcium group lesions were characterized by a more severe acute PFA response with contraction band necrosis, myocytolysis and nuclear pyknosis in adjacent myocardium, in addition to microhemorrhages.ConclusionInfusing calcium chloride locally after PFA markedly improves the immediate efficacy of electroporation in porcine atria. This study suggests that calcium electroporation could bolster PFA outcomes without higher energy levels, potentially diminishing associated risks. These preliminary findings warrant further research into the long‐term efficacy and potential clinical application of calcium electroporation in PFA.
Effects of Pulsed Electric Fields on the Coronary Arteries in Swine
Background: Previous animal studies have shown no significant vascular injury from pulsed electrical field (PEF) ablation. We sought to assess the effect of PEF on swine coronary arteries. Methods: We performed intracoronary and epicardial (near the coronary artery) PEF ablations in swine pretreated with dual antiplatelet and antiarrhythmic therapy. Intracoronary PEF was delivered using MapiT catheters (Biotronik, Berlin), whereas epicardial PEF was delivered using EPT catheters (Boston Scientific, MA). PEF pulse duration was microseconds (Nanoknife 3.0, Angio Dynamics, NY) or nanoseconds (CellFX, Pulse Biosciences, CA). Results: We performed 39 intracoronary ablations in 10 swine and 20 epicardial-pericoronary ablations in 4 separate swine. Intracoronary PEF was delivered at higher energy compared with epicardial PEF (46 [interquartile range, IQR 20–85] J versus 10 [IQR 10–11] J, P < 0.01). Reversible coronary spasm occurred in 49% intracoronary ablations and 45% epicardial ablations ( P =0.80). At the end study, fixed coronary stenosis was demonstrated in 44% intracoronary ablations (80% for microsecond PEF and 18% for nanosecond PEF) and 0% epicardial ablations. Visible hemorrhagic and/or fibrotic myocardial lesions were observed at necropsy with similar frequency between intracoronary and epicardial PEF (45% versus 50%, P =0.70). Nanosecond PEF (49 ablations in 11 swine), when compared with microsecond PEF (10 intracoronary ablations in 3 swine), resulted in lower energy delivery (21 [IQR 10–46] J versus 129 [IQR 24–143] J, P =0.03) and less incidence of fixed coronary stenosis (18% versus 80%, P =0.04). Conclusions: In the swine model, intracoronary PEF resulted both in significant coronary spasm and fixed coronary stenosis. Epicardial PEF, delivered at lower energy, resulted in reversible spasm but no fixed coronary stenosis.
Regional and Temporal Variation of Ventricular and Conduction Tissue Activity During Ventricular Fibrillation in Canines
Background: Rigorous study of ventricular fibrillation (VF) is not feasible in humans. The spatiotemporal characteristics of prolonged VF remain undefined, limiting our understanding of this lethal rhythm. Methods: VF was mapped in 4 canines. The endocardial and epicardial left ventricle (LV) and right ventricle (RV) were sequentially mapped at 0 to 15, 15 to 30, 30 to 45, and 45 to 60 minutes post-induction. Ten consecutive beats were used to determine the average cycle length and regularity index of ventricular and His-Purkinje system signals in discrete regions during each time interval. Results: Average VF time was 58±12 minutes. The shortest ventricular cycle length was present in the RV apical region (70±10 msec) at 0 to 15 minutes and at 15 to 30 minutes (89±31 msec) and LV apical region at 45 to 60 minutes (242±163 msec). The His-Purkinje system cycle length was the shortest at the RV outflow tract (75±3 msec) at 0 to 15 minutes, RV inflow and free wall (89±12 msec) at 15 to 30 minutes, LV apical region (83±14 msec) at 30 to 45 minutes, and inferior and inferolateral LV (145±23 msec) at 45 to 60 minutes. Regularity index was the highest in the RV inflow and free wall (78%) at 0 to 15 minutes, RV apical region (86%) at 15 to 30 minutes, LV septum and epicardial anterior RV (80%) at 30 to 45 minutes, and anterior and anterolateral LV (75%) at 45 to 60 minutes. Conclusions: These data suggest significant regional changes in electrical activity throughout VF in canines. A transition of fastest electrical activity from RV to LV apical regions across VF was observed. These novel insights of the temporal and spatial changes of VF merit further evaluation in diseased hearts to assess for reproducibility of findings.