Back to Authors

van Zyl, Martin

0000-0001-9131-8978

Mayo Clinic

Division of Cardiology, Royal Jubilee Hospital, Victoria, BC, Canada (M.v.Z.).

Citations 5

Safety and Efficacy With Pulsed Field Ablation: Having the Cake and Eating It Too
Zyl, Martin van , Asirvatham, Samuel J. , van Zyl, Martin , Asirvatham, Samuel J

Circulation: Arrhythmia and Electrophysiology | March 27, 2023 | Volume: 16 | Issue: 4 | Pages: No page available

10.1161/circep.123.011955 Get It

Effects of Pulsed Electric Fields on the Coronary Arteries in Swine
Ladejobi, Adetola, Christopoulos, Georgios , Tan, Nicholas Y. , Ladas, Thomas P. , Tri, Jason , Zyl, Martin van , Yasin, Omar , Sugrue, Alan , Khabsa, Mariam , Uecker, Darrin, Danitz, David J., Killu, Ammar M. , Holmes, David R. , Asirvatham, Samuel J. , Munoz, Freddy Del‐Carpio , Tan, Nicholas , van Zyl, Martin , DeSimone, Christopher V , Killu, Ammar M , Maor, Elad , Holmes, David R , Asirvatham, Samuel J , Del-Carpio Munoz, Freddy , Tri, Jason A , Christopoulos, Georgios, Connolly, Richard J. , DeSimone, Christopher V. , Maor, Elad

Circulation: Arrhythmia and Electrophysiology | October 4, 2022 | Volume: 15 | Issue: 10 | Pages: No page available

10.1161/circep.121.010668 Get It

Background: Previous animal studies have shown no significant vascular injury from pulsed electrical field (PEF) ablation. We sought to assess the effect of PEF on swine coronary arteries. Methods: We performed intracoronary and epicardial (near the coronary artery) PEF ablations in swine pretreated with dual antiplatelet and antiarrhythmic therapy. Intracoronary PEF was delivered using MapiT catheters (Biotronik, Berlin), whereas epicardial PEF was delivered using EPT catheters (Boston Scientific, MA). PEF pulse duration was microseconds (Nanoknife 3.0, Angio Dynamics, NY) or nanoseconds (CellFX, Pulse Biosciences, CA). Results: We performed 39 intracoronary ablations in 10 swine and 20 epicardial-pericoronary ablations in 4 separate swine. Intracoronary PEF was delivered at higher energy compared with epicardial PEF (46 [interquartile range, IQR 20–85] J versus 10 [IQR 10–11] J, P < 0.01). Reversible coronary spasm occurred in 49% intracoronary ablations and 45% epicardial ablations ( P =0.80). At the end study, fixed coronary stenosis was demonstrated in 44% intracoronary ablations (80% for microsecond PEF and 18% for nanosecond PEF) and 0% epicardial ablations. Visible hemorrhagic and/or fibrotic myocardial lesions were observed at necropsy with similar frequency between intracoronary and epicardial PEF (45% versus 50%, P =0.70). Nanosecond PEF (49 ablations in 11 swine), when compared with microsecond PEF (10 intracoronary ablations in 3 swine), resulted in lower energy delivery (21 [IQR 10–46] J versus 129 [IQR 24–143] J, P =0.03) and less incidence of fixed coronary stenosis (18% versus 80%, P =0.04). Conclusions: In the swine model, intracoronary PEF resulted both in significant coronary spasm and fixed coronary stenosis. Epicardial PEF, delivered at lower energy, resulted in reversible spasm but no fixed coronary stenosis.
Substrate Characterization and Outcomes of Catheter Ablation of Ventricular Arrhythmias in Patients With Mitral Annular Disjunction
Ezzeddine, Fatima M. , Siontis, Konstantinos C. , Giudicessi, John R. , Ackerman, Michael J. , Killu, Ammar M. , Deshmukh, Abhishek , Madhavan, Malini , Zyl, Martin van , Vaidya, Vaibhav R. , Karki, Roshan , Munger, Thomas M. , Asirvatham, Samuel J. , Munoz, Freddy Del‐Carpio , Giudicessi, J R , Deshmukh, Abhishek J , van Zyl, Martin , Tseng, A S , McLeod, Christopher J , Asirvatham, Samuel J , Del-Carpio Munoz, Freddy , Ezzeddine, Fatima , Tseng, Andrew S. , McLeod, Christopher J.

Circulation: Arrhythmia and Electrophysiology | September 8, 2022 | Volume: 15 | Issue: 9 | Pages: No page available

10.1161/circep.122.011088 Get It

Background: Mitral annular disjunction (MAD) has recently been recognized as an arrhythmogenic entity. Data on the electrophysiological substrate as well as the outcomes of catheter ablation of ventricular arrhythmias in patients with MAD is limited. Methods: Forty patients with MAD (mean age 47±15 years; 70% female) underwent catheter ablation for ventricular arrhythmias. Detailed clinical, electrocardiographic, cardiac imaging, and procedural data were collected. Clinical outcomes were compared between patients who had substrate modification in the MAD area and those who did not. Results: Twenty-three (57.5%) patients had ablation for premature ventricular contractions, 10 (25%) patients for sustained ventricular tachycardia, and 7 (17.5%) patients for premature ventricular contraction-triggered ventricular fibrillation. Mean end-systolic MAD length was 10.58±3.49 mm on transthoracic echocardiography. Seventeen (42.5%) patients had preprocedural cardiac magnetic resonance imaging, and 5 (29%) patients had late gadolinium enhancement. Among the 18 (45%) patients who had abnormal local electrograms (low voltage, long-duration, fractionated, isolated mid-diastolic potentials) during electroanatomical mapping, 10 (25%) patients had abnormal electrograms in the anterolateral mitral annulus and/or MAD area. Substrate modification was performed in 10 (25%) patients. Catheter ablation was acutely successful in 36 (90%) patients (elimination of premature ventricular contraction or noninducibility of ventricular tachycardia). After a median follow-up duration of 54.08 (interquartile range, 10.67–89.79) months, premature ventricular contraction burden decreased from a median of 9.75% (interquartile range, 3.25–14) before the ablation to a median of 4% (interquartile range, 1–7.75) after the ablation ( P =0.03 [95% CI, 0.055–6.5]). Eight (20.5%) patients had repeat ablation for ventricular arrhythmias. Substrate modification of the MAD was associated with a trend toward lower rates of repeat ablation (0% versus 26.7%; P =0.16). Conclusions: Patients with MAD have a complex arrhythmogenic substrate, and catheter ablation is effective in reducing recurrence of ventricular arrhythmias. Substrate mapping and ablation may be considered in these patients.
A sound method for axillary vein access
Zyl, Martin van , Deshmukh, Abhishek , van Zyl, Martin , Deshmukh, Abhishek J

Journal of Cardiovascular Electrophysiology | December 18, 2020 | Volume: 32 | Issue: 2 | Pages: 466-467

10.1111/jce.14839 Get It

Injectable conductive hydrogel restores conduction through ablated myocardium
Zyl, Martin van , Pedrotty, Dawn , Kuzmenko, Volodymyr , Sämfors, Sanna, Livia, Christopher , Vaidya, Vaibhav R. , Sugrue, Alan , Behfar, Atta , Asirvatham, Samuel J. , Gatenholm, Paul , Kapa, Suraj , van Zyl, Martin , Livia, Christopher , Vaidya, Vaibhav , Sugrue, Alan , Asirvatham, Samuel J , Gatenholm, Paul , Kapa, Suraj , Behfar, Atta , Karabulut, Erdem , McLeod, Christopher J.

Journal of Cardiovascular Electrophysiology | September 23, 2020 | Volume: 31 | Issue: 12 | Pages: 3293-3301

10.1111/jce.14762 Get It

AbstractIntroductionTherapies for substrate‐related arrhythmias include ablation or drugs targeted at altering conductive properties or disruption of slow zones in heterogeneous myocardium. Conductive compounds such as carbon nanotubes may provide a novel personalizable therapy for arrhythmia treatment by allowing tissue homogenization.MethodsA nanocellulose carbon nanotube‐conductive hydrogel was developed to have conduction properties similar to normal myocardium. Ex vivo perfused canine hearts were studied. Electroanatomic activation mapping of the epicardial surface was performed at baseline, after radiofrequency ablation, and after uniform needle injections of the conductive hydrogel through the injured tissue. Gross histology was used to assess distribution of conductive hydrogel in the tissue.ResultsThe conductive hydrogel viscosity was optimized to decrease with increasing shear rate to allow expression through a syringe. The direct current conductivity under aqueous conduction was 4.3 × 10−1 S/cm. In four canine hearts, when compared with the homogeneous baseline conduction, isochronal maps demonstrated sequential myocardial activation with a shift in direction of activation to surround the edges of the ablated region. After injection of the conductive hydrogel, isochrones demonstrated conduction through the ablated tissue with activation restored through the ablated tissue. Gross specimen examination demonstrated retention of the hydrogel within the tissue.ConclusionsThis proof‐of‐concept study demonstrates that conductive hydrogel can be injected into acutely disrupted myocardium to restore conduction. Future experiments should focus on evaluating long‐term retention and biocompatibility of the hydrogel through in vivo experimentation.