Back to Authors

Ward, Robert C

0000-0001-8115-413X

Mayo Clinic

Department of Cardiovascular Medicine, Mayo Clinic, Rochester (K.Q.A., J.A.T., I.U.H., A.W., H.N., A.B., S.Y., R.W., F.E., N.Y.T., F.D.-C.M., S.A., C.V.D.).

Citations 5

Ventricular Fibrillation Mapping in a Large-Animal Model Using Dual Mechanical Circulatory Support: Electroanatomic Substrate Preservation Without Ischemic Changes
Quelal, Karol , Tri, Jason , Haq, Ikram-Ul , Welle, Amalia, Niu, Hanxu, Behfar, Atta , Yalamuri, Suraj , Ward, Robert C. , Ezzeddine, Fatima M. , Tolkacheva, Elena G. , Tan, Nicholas Y. , Munoz, Freddy Del‐Carpio , Asirvatham, Samuel J. , DeSimone, Christopher V. , Quelal, Karol , Tri, Jason A , Haq, Ikram U , Ward, Robert C , Ezzeddine, Fatima , Tolkacheva, E G , Del-Carpio Munoz, Freddy , Asirvatham, Samuel J , Behfar, Atta , Welle, Amalia A., Yalamuri, Suraj

Circulation: Arrhythmia and Electrophysiology | September 18, 2026 | Volume: No volume available | Issue: No issue available | Pages: No page available

10.1161/circep.126.014954 Get It

BACKGROUND: Ventricular fibrillation (VF) remains a leading cause of sudden cardiac death with an incompletely characterized electrophysiological substrate. Traditional large-animal VF models are limited by hemodynamic collapse and myocardial ischemia. This study establishes a reproducible swine model using dual mechanical circulatory devices to enable high-density electroanatomic mapping under nonischemic conditions. METHODS: Five Yorkshire swine (55–65 kg) underwent sustained VF supported by venoarterial extracorporeal membrane oxygenation (2.5–3.0 L/min) and percutaneous left ventricular unloading (Impella CP, P-2–P-4). High-density electroanatomic mapping using CARTO 7 was performed at baseline and after defibrillation. Bipolar voltage was acquired from 7 predefined ventricular regions (21 measurements per animal per time point; n=210 paired observations). Unipolar voltage mapping and continuous surface ECG monitoring were used to assess acute ischemic injury. Systemic perfusion was maintained at systolic arterial pressure ≥80 mm Hg. Linear mixed-effects modeling was used to analyze voltage changes from pre-VF to post-VF. RESULTS: Sustained VF (10±1 minutes) was reproducibly induced and maintained with consistent hemodynamics (systolic arterial pressure, 90±5 mm Hg; extracorporeal membrane oxygenation flow, 2.5±0.5 L/min). All animals were successfully defibrillated. High-density mapping was feasible in all experiments (1000±300 points per chamber). Bipolar voltage showed no change from pre-VF (5.86±2.56 mV) to post-VF (6.53±2.22 mV; mean difference, 0.67 mV [95% CI, –0.31 to 1.65]; P =0.15). Both left ( P =0.17) and right ventricles ( P =0.08) demonstrated voltage preservation. Regional analysis showed no significant changes (all P >0.05); post-VF voltages remained above viability thresholds (>1.5 mV). Unipolar voltage maps recovered toward baseline, with no ECG injury pattern identified after defibrillation. CONCLUSIONS: Dual mechanical circulatory support with venoarterial extracorporeal membrane oxygenation and Impella CP enables reproducible, high-fidelity electroanatomic mapping and preserves myocardial substrate after sustained VF in a large-animal model. This platform overcomes key technical barriers in VF research, providing a nonischemic foundation for future mechanistic and translational studies.
Step‐By‐Step: Subclavian Venoplasty to Facilitate Cardiac Implantable Electronic Device Upgrade
Haq, Ikram-Ul , Ward, Robert C. , Mulpuru, Siva K. , Haq, Ikram U , Ward, Robert C

Journal of Cardiovascular Electrophysiology | August 1, 2025 | Volume: 36 | Issue: 10 | Pages: 2577-2586

10.1111/jce.16784 Get It

ABSTRACT Introduction Lead‐related venous obstruction is a significant complication of chronic indwelling transvenous leads, which poses unique challenges during cardiac device upgrades. Background The anatomical sequelae of venous occlusion are variable and carry important procedural implications. Occlusions can develop in any part of the venous system, but they most often occur in the subclavian and innominate veins, while the superior vena cava is less frequently affected. Methods In this review, we describe approaches to lead‐related venous occlusion providing step‐by‐step procedural guidance. Results Venoplasty, neovascular channel creation are two main techniques for addressing lead‐related venous obstruction. Conclusion Venoplasty in the setting of an indwelling pacemaker or defibrillator leads can be performed safely and effectively. The difficulty of the procedure lies in crossing the obstruction. Familiarity with various tools is needed for a successful outcome.
First‐in‐man report of transsubclavian venous implantation of the Aveir leadless cardiac pacing system
Ward, Robert C. , Amin, Hina , Noseworthy, Peter A. , Asirvatham, Samuel J. , Friedman, Paul A. , Mulpuru, Siva K. , Balanescu, Dinu V , Ward, Robert C , Noseworthy, Peter A , Asirvatham, Samuel J , Friedman, Paul A , Mulpuru, Siva K , Balanescu, Dinu Valentin

Journal of Cardiovascular Electrophysiology | March 11, 2024 | Volume: 35 | Issue: 5 | Pages: 1041-1045

10.1111/jce.16241 Get It

Abstract Introduction Transsubclavian venous implantation of the Aveir leadless cardiac pacemaker (LCP) has not been previously reported. Methods and Results Three cases of transsubclavian implantation of the Aveir LCP are reported. Two cases were postbilateral orthotopic lung transplant, without appropriate femoral or jugular access due to recent ECMO cannulation and jugular central venous catheters. In one case, there was strong patient preference for same‐day discharge. Stability testing confirmed adequate fixation and electrical testing confirmed stable parameters in all cases. All patients tolerated the procedure well without significant immediate complications. Conclusions We demonstrate the feasibility of transsubclavian implantation of the Aveir LCP.
Idiopathic Ventricular Tachycardia
Ward, Robert C. , Zyl, Martin van , Ward, Robert C , DeSimone, Christopher V.

Journal of Clinical Medicine | January 26, 2023 | Volume: 12 | Issue: 3 | Pages: 930

10.3390/jcm12030930 Get It

Idiopathic ventricular tachycardia (VT) is an important cause of morbidity and less commonly, mortality in patients with structurally normal hearts. Appropriate diagnosis and management are predicated on an understanding of the mechanism, relevant cardiac anatomy, and associated ECG signatures. Catheter ablation is a viable strategy to adequately treat and potentially provide a cure in patients that are intolerant to medications or when these are ineffective. In this review, we discuss special approaches and considerations for effective and safe ablation of VT arising from the right ventricular outflow tract, left ventricular outflow tract, left ventricular fascicles, papillary muscles, and moderator band.
Cardiac magnetic resonance imaging is a promising modality for left atrial appendage occlusion planning
Ward, Robert C. , Deshmukh, Abhishek , Deshmukh, Abhishek J , Ward, Robert C

Journal of Cardiovascular Electrophysiology | October 27, 2022 | Volume: 33 | Issue: 12 | Pages: 2651-2652

10.1111/jce.15721 Get It