Transcatheter Valve Replacement in Adults With Congenital Heart Disease—The Mayo Clinic Experience
Egbe, Alexander C. , Cabalka, Allison K. , Hagler, Donald J. , Eleid, Mackram F. , Rihal, Charanjit S. , Anderson, Jason H. , Taggart, Nathaniel W , Hagler, Donald J , Eleid, Mackram F , Rihal, Charanjit S. , Anderson, Jason , Cabalka, Allison , Taggart, Nathaniel W.

Circulation: Cardiovascular Interventions | October 27, 2025 | Volume: 18 | Issue: 12 | Pages: No page available

10.1161/circinterventions.125.015667 Get It

BACKGROUND: The current study aims to describe outcomes after transcatheter valve replacement in adults with congenital heart disease. METHODS: Retrospective study of adults with congenital heart disease who underwent transcatheter valve replacement and had a 1-year follow-up postintervention at Mayo Clinic (2010–2024). The study period was divided into early (2010–2014), mid (2015–2019), and late (2020–2024) eras. The primary outcome was valve reintervention. The secondary outcomes were all-cause mortality and temporal change in prosthetic valve gradient and clinical indices of disease severity. RESULTS: Overall, 341 patients (age 38±17 years; 175 [51%] men) received 346 prostheses (pulmonary [N=236, 68%], tricuspid [N=75, 22%], aortic [N=22, 8%], and mitral [N=7, 2%]). The prostheses were Sapien (N=181, 52%), Melody (N=142, 41%), and Harmony prostheses (N=23, 7%). The number of transcatheter valve implantations increased from the early era (N=75), mid era (N=109), to the late era (N=162). The 10-year incidence of valve reintervention was 35%, and was similar between Sapien versus Melody prosthesis (41% versus 33%; P =0.11). The 10-year incidence of all-cause mortality was 13%. There was a temporal increase in prosthetic valve Doppler mean gradient (baseline versus 10 years) for pulmonary (12±5 versus 28±11 mmHg; P <0.001), tricuspid (3±1 versus 8±3 mmHg; P <0.001), and aortic prosthesis (13±5 versus 26±12 mmHg; P <0.001). There was a temporal increase in predicted peak oxygen consumption (absolute ∆, 9% [95% CI, 4–13]; P =0.006) and a decrease in NT-proBNP (N-terminal pro-B-type natriuretic peptide) level (absolute ∆, −138 pg/mL [95% CI, −209 to −64]; P <0.001) at 1-year postintervention. CONCLUSIONS: There has been a temporal increase in the number of transcatheter valve implantations over time. Transcatheter valve replacement was associated with clinical improvement across multiple domains. However, there was a significant increase in prosthetic valve gradient within 10 years of follow-up, suggesting limited prosthesis longevity. There is a need for strategies to improve prosthetic valve longevity, which in turn may improve outcomes in this population.
Self‐Expanding Aortic Endoprosthesis for Conduit Preparation Prior to Transcatheter Pulmonary Valve Replacement
Krebushevski, Kaitlyn , Cabalka, Allison K. , Pollak, Peter , Yu, Liwei , Anderson, Jason H. , Pollak, Peter M , Cabalka, Allison , Anderson, Jason

Catheterization and Cardiovascular Interventions | July 30, 2025 | Volume: 106 | Issue: 4 | Pages: 2244-2251

10.1002/ccd.70039 Get It

ABSTRACT Background Preparation of the right ventricular outflow tract (RVOT) using covered stent placement is a common preparatory step for transcatheter pulmonary valve replacement (TPVR) to reduce the risk of disruption associated with dilating calcified RVOT conduits. Aim We present a novel method employing a self‐expanding covered aortic endoprosthesis and discuss its advantages as an alternative strategy. Methods Patients with congenital heart disease undergoing RVOT conduit preparation with the GORE TAG Thoracic Branch Endoprosthesis Extender (W.L. Gore & Associates, Newark, DE) followed by TPVR, were prospectively enrolled in a dedicated database. To date, 14 patients have been included. Data on demographics, diagnoses, procedural details, hemodynamic parameters, and outcomes were analyzed. Results Fourteen patients (median age: 35 years [range: 18–79]; 57% female) successfully underwent endograft placement immediately before TPVR. Treated conduits included pulmonary homografts ( n = 8), surgical bioprostheses ( n = 2), Hancock conduit ( n = 1), Contegra conduit ( n = 1), native RVOT ( n = 1), and Melody valve within a surgical bioprosthesis ( n = 1). Most patients presented with mixed stenosis and regurgitation ( n = 9), with the remaining having stenosis ( n = 4) or regurgitation ( n = 1). Valves implanted post‐preparation included the Sapien S3 valve (Edwards Lifesciences, Irvine, CA) ( n = 10) and the Melody valve (Medtronic, Minneapolis, MN) ( n = 5). Significant reductions in RVOT systolic gradient were observed (median 34 mmHg pre‐procedure to 3 mmHg post‐procedure), along with marked conduit expansion (median diameter 13 mm pre‐procedure to 25.5 mm post‐procedure). No complications were reported. Conclusions This study highlights the feasibility of a self‐expanding aortic endoprosthesis for RVOT preparation before TPVR. Further comparative study is warranted. Procedural success was achieved in all cases.
Midterm Outcomes in a Pooled Cohort of Harmony Transcatheter Pulmonary Valve Recipients
Morray, Brian H. , Gillespie, Matthew J. , Cheatham, John P. , Salavitabar, Arash , Peng, Lynn F., Jones, Thomas K. , Levi, Daniel S. , Gray, Robert G. , Asnes, Jeremy D. , Cabalka, Allison K. , Fujimoto, Kazuto , Qureshi, Athar M. , Bergersen, Lisa, Haugan, Daniel, McElhinney, Doff B. , Asnes, Jeremy D , Benson, Lee N. , McElhinney, Doff B , Jones, Thomas K , Morray, Brian H , Cabalka, Allison , Bergersen, Lisa

Circulation: Cardiovascular Interventions | July 16, 2025 | Volume: 18 | Issue: 9 | Pages: No page available

10.1161/circinterventions.125.015196 Get It

BACKGROUND: The Harmony transcatheter pulmonary valve (TPV) is designed to treat severe pulmonary regurgitation in the native or surgically repaired right ventricular (RV) outflow tract. Early outcomes after TPV replacement with the Harmony valve have been positive, but longer-term data are limited. METHODS: The study included patients who received a commercially available TPV22 or TPV25 device as part of the nonrandomized, prospective Native Outflow Tract Early Feasibility Study, Harmony Pivotal Trial, and Continued Access Study. Patients completed at least 3 years of follow-up, and outcomes to 5 years were reported when available. RESULTS: Eighty-nine patients were catheterized, and 86 were successfully implanted with a Harmony TPV. Median duration of follow-up was 5 (range 0–6) years in the TPV22 group and 3 (1–4) years in the TPV25 group. At 3 years, all patients with a TPV22 and 96% of those with a TPV25 had ≤mild pulmonary regurgitation. By magnetic resonance imaging, significant improvements from preimplant to 2 years were observed in RV end-diastolic volume index, RV to left ventricular end-diastolic volume ratio, and effective RV stroke volume (all P <0.001). SF-36 quality-of-life scores improved after Harmony implantation and were sustained over 3 years. Early cases of ventricular tachycardia resolved, and there were no new arrhythmias. Adverse events up to 5 years included 3 deaths unrelated to the device or procedure, 2 cases of endocarditis that were treated (1 medically, 1 transcatheter debulking of a vegetation) and resolved, 6 patients with RV outflow tract obstruction or thrombosis resulting in valve-in valve procedures, and 1 major stent fracture resulting in surgical explant. CONCLUSIONS: At 3 to 5 years, Harmony TPV replacement resulted in sustained valve competence, beneficial cardiac remodeling, and improved quality of life. Continued monitoring is needed to assess long-term outcomes and valve performance. REGISTRATION: URL: https://www.clinicaltrials.gov ; Unique identifier: NCT01762124; NCT02979587.
Transcatheter Pulmonary Flow Restrictors as a Palliative Bridge to Heart Transplant
Masilamani, Mats Steffi Jennifer , Johnson, Jonathan N. , Ameduri, Rebecca , Stephens, Elizabeth H. , Cabalka, Allison K. , Anderson, Jason H. , Ameduri, Rebecca K , Cabalka, Allison , Anderson, Jason

Pediatric Transplantation | January 21, 2025 | Volume: 29 | Issue: 1 | Pages: No page available

10.1111/petr.70025 Get It

ABSTRACT Background In recent years, transcatheter implantation devices to restrict pulmonary arterial flow have emerged as a potential alternative to surgical pulmonary artery banding. Case Presentation A term male was diagnosed with critical aortic stenosis (AS) and severely reduced left ventricle (LV) systolic function. He underwent aortic balloon valvuloplasty on day 2 of life, resulting in some antegrade flow, but LV ejection fraction only improved to 15%. He remained ductal dependent for systemic perfusion. Pulmonary over‐circulation ensued with systemic steal evident in his second week of life. On day 14, he underwent a transcatheter stage 1 procedure including the placement of bilateral pulmonary flow restrictor (PFR) devices and ductal stenting. Post‐procedure, he improved clinically, weaned off respiratory support, and transitioned to oral feeds while awaiting cardiac transplant. Twelve days later, he received a donor heart, with an uneventful recovery. He is now 3 years post‐transplant and has excellent graft function, and his transplant course has been unremarkable. Conclusion Transcatheter‐based palliation for a neonate with critical AS, utilizing endoluminal PFRs, proved effective in stabilizing the infant and successfully bridging him to transplant. This highlights an opportunity for the utilization of PFRs in neonatal conditions where control of pulmonary blood flow is imperative as a bridge to transplantation.
Feasibility of intentional bioprosthetic valve fracture in the tricuspid position
Hagel, Jonathon A. , Qureshi, Athar M. , Tanase, Daniel , Eicken, Andreas , Zampi, Jeffrey D. , Cabalka, Allison K. , Anderson, Jason H. , Shahanavaz, Shabana , Qureshi, Athar M , Tanase, Daniel , Zampi, Jeffrey D , Cabalka, Allison , Anderson, Jason , Lin, C. Huie

Catheterization and Cardiovascular Interventions | August 1, 2024 | Volume: 104 | Issue: 3 | Pages: 523-530

10.1002/ccd.31168 Get It

AbstractBackgroundTranscatheter tricuspid valve‐in‐valve (ViV) replacement has yielded good hemodynamic outcomes in the treatment of dysfunctional bioprosthetic valves (BPVs). Intentional fracture of certain rigid BPV frames, if feasible, allows a larger implanted valve when compared with implant into an unfractured BPV. There remains limited data on the feasibility of tricuspid valve frame fracture.AimsEvaluate the feasibility of transcatheter tricuspid ViV replacement with fracture of the underlying BPV ring.MethodsAn international multicenter registry of tricuspid ViV replacement with intentional tricuspid valve frame fracture was created. Demographic data along with procedural characteristics, outcomes, and follow‐up data were collected. Comparison was made to the pre‐ and post‐ViV replacement with fracture of the tricuspid valve frame conditions.ResultsTen patients from six centers were included with a median age and weight of 29 years and 67.3 kg respectively. Tricuspid valve frame fracture was performed using a median balloon diameter 3 mm (IQR 3–5) larger than the true inner diameter (ID). The final ID was a mean of 1.5 mm (95% CI: 0.35, 2.64: p < 0.05), and median 1.1 mm (0.5, 2.1) larger than the reported true ID of the surgical BPV after ViV replacement. The mean tricuspid inflow gradient by echocardiogram decreased by 6.65 mmHg (95% CI: 4.14, 9.15: p < 0.001). All procedures were without complication, specifically there was no heart block, pericardial effusion, or right coronary disruption.ConclusionIntentional tricuspid valve frame fracture with tricuspid ViV replacement is feasible and can increase the valve orifice potentially reducing the risk of ViV patient prosthesis mismatch and is not associated with significant complications.
Transcatheter Pulmonary Valve Replacement With the Harmony Valve in Patients Who Do Not Meet Recommended Oversizing Criteria on the Screening Perimeter Plot
McElhinney, Doff B. , Gillespie, Matthew J. , Cabalka, Allison K. , Morray, Brian H. , Balzer, David T. , Qureshi, Athar M. , Hoskoppal, Arvind , Cabalka, Allison , Morray, Brian H , Qureshi, Athar M , Hoskoppal, Arvind K , Goldstein, Bryan H , McElhinney, Doff B , Aboulhosn, Jamil , Goldstein, Bryan H.

Circulation: Cardiovascular Interventions | April 12, 2024 | Volume: 17 | Issue: 5 | Pages: No page available

10.1161/circinterventions.123.013889 Get It

BACKGROUND: Anatomic selection for Harmony valve implant is determined with the aid of a screening report and perimeter plot (PP) that depicts the perimeter-derived radius along the right ventricular outflow tract (RVOT) and projects device oversizing. The PP provides an estimation of suitability for implant, but its sensitivity as a screening method is unknown. This study was performed to describe anatomic features and outcomes in patients who underwent Harmony TPV25 implant despite a PP that predicted inadequate oversizing. METHODS: We reviewed RVOT anatomic features and measurements in patients who underwent transcatheter pulmonary valve replacement with the Harmony TPV25 device despite a PP that predicted inadequate oversizing. RESULTS: This study included 22 patients. There were no unsuccessful implants or adverse valve-related events. Anatomic features varied, but all patients fit into 1 of 3 anatomic types characterized by differences in RVOT dimensions. Type 1 patients (n=9) had a long RVOT with a choke point and a wide main pulmonary artery. Type 2 patients (n=6) had a short RVOT that was pyramidal in shape, with no choke point, and extensive main pulmonary artery lengthening/expansion during systole. Type 3 patients (n=7) had a short, bulbous main pulmonary artery with a choke point and an open pulmonary artery bifurcation. CONCLUSIONS: Transcatheter pulmonary valve replacement with the Harmony valve is feasible in some patients whose PP fit analysis predicts inadequate oversizing. All cases in this series fit into 1 of 3 anatomic patterns, which are not identified in the screening report. Implanters must review cases individually to assess the feasibility of the implant.
Cardiac Reverse Remodeling and Changes in Heart Failure Indices After Transcatheter Tricuspid Valve Replacement in Adults With Congenital Heart Disease
Salama, Abdalla A., Miranda, William R. , Connolly, Heidi M. , Jain, Charles, Cabalka, Allison K. , Egbe, Alexander C. , Abozied, Omar A, Anderson, Jason H. , Miranda, William R , Connolly, Heidi M , Cabalka, Allison , Egbe, Alexander C , Abozied, Omar

Circulation: Cardiovascular Interventions | November 9, 2023 | Volume: 17 | Issue: 1 | Pages: No page available

10.1161/circinterventions.123.013334 Get It

BACKGROUND: There are limited data about changes in cardiac function (cardiac reverse remodeling) and heart failure indices after transcatheter tricuspid valve-in-valve replacement (TT-VIVR). The purpose of this study was to evaluate cardiac reverse remodeling and temporal changes in heart failure indices after TT-VIVR in adults with congenital heart disease. METHODS: Retrospective cohort study of adults with congenital heart disease that underwent TT-VIVR and had >6 months of follow-up (January 1, 2011, to April 30, 2023). Echocardiographic indices of cardiac remodeling and heart failure indices (New York Heart Association class, NT-proBNP (N-terminal pro-brain natriuretic peptide), glomerular filtration rate, and model for end-stage liver disease excluding international normalized ratio score) were assessed preintervention and at 1-, 3-, and 5-year postintervention. RESULTS: Of 39 patients (age 39 [32–46] years), 14 (36%) and 25 (64%) received Melody valve and Sapien valve prosthesis, respectively. At 1-year post-TT-VIVR, there was a temporal improvement in right atrial reservoir strain (17±8% versus 22±8%, P <0.001), right atrial volume (81 [59–108] versus 63 [48–82] mL/m 2 , P <0.001), right atrial pressure (12±4% versus 6±4%, P <0.001), and right ventricular global longitudinal strain (−15±7% versus −20±7%, P <0.001). Similarly, there was a temporal improvement in NT-proBNP, glomerular filtration rate, model for end-stage liver disease excluding international normalized ratio score, and New York Heart Association class. The temporal improvements in heart failure indices and valve function were maintained at 3- and 5-year post-TT-VIVR. CONCLUSIONS: Considering the significant mortality risk associated with reoperations for tricuspid valve replacement, these data suggest favorable outcomes after TT-VIVR, and support TT-VIVR as a viable alternative to surgical tricuspid valve replacement, especially in high-risk patients.
Transcatheter closure of coronary artery fistula: A 21‐year experience
El‐Sabawi, Bassim , Al‐Hijji, Mohammed , Eleid, Mackram F. , Cabalka, Allison K. , Ammash, Naser M., Dearani, Joseph A. , Bjarnason, Haraldur , Holmes, David R. , Rihal, Charanjit S. , Al-Hijji, Mohammed A , Cabalka, Allison , Bjarnason, Haraldur , Dearani, Joseph A. , Rihal, Charanjit S.

Catheterization and Cardiovascular Interventions | January 10, 2020 | Volume: 96 | Issue: 2 | Pages: 311-319

10.1002/ccd.28721 Get It

AbstractObjectivesTo evaluate the outcomes of transcatheter coronary artery fistula (CAF) closure and to identify anatomic/procedural factors that may impact outcomes.BackgroundDue to the rarity of CAF, reported experience with transcatheter closure remains limited and anatomic and procedural factors that may lead to unsuccessful closure, complications, or recanalization of CAF are unclear.MethodsAll patients who underwent transcatheter CAF closure at Mayo Clinic from 1997 to 2018 were retrospectively reviewed. CAF anatomic characteristics, procedural techniques, and clinical/angiographic outcomes were assessed.ResultsA total of 45 patients underwent transcatheter closure of 56 CAFs. The most commonly used devices were embolization coils in 40 (71.4%) CAFs, vascular occluders in 10 (17.8%), or covered stent in 2 (3.6%). Acute procedural success with no or trivial residual flow occurred in 50 (89.3%) CAFs. Residual flow was small in three (5.4%) and large in three (5.4%). Eight (17.8%) patients had complications, including device migration in three, intracranial hemorrhage from anticoagulation in one, and myocardial infarction (MI) in four. MI was a result of covered stent thrombosis or stagnation of flow after closure of large distal CAF. Twenty‐two patients with 27 CAFs had follow‐up angiography after successful index procedure at median time of 423 (IQ 97‐1348) days. Of these, 23 (85.2%) had no/trace flow and 4 had large flow from recanalization.ConclusionsTranscatheter CAF closure is associated with a favorable acute procedural success and complication rate in selected patients. Procedural success and risk for complication are highly dependent on CAF anatomy and closure technique.