Transcatheter Pulmonary Valve Replacement With the Harmony Valve in Patients Who Do Not Meet Recommended Oversizing Criteria on the Screening Perimeter Plot
BACKGROUND: Anatomic selection for Harmony valve implant is determined with the aid of a screening report and perimeter plot (PP) that depicts the perimeter-derived radius along the right ventricular outflow tract (RVOT) and projects device oversizing. The PP provides an estimation of suitability for implant, but its sensitivity as a screening method is unknown. This study was performed to describe anatomic features and outcomes in patients who underwent Harmony TPV25 implant despite a PP that predicted inadequate oversizing. METHODS: We reviewed RVOT anatomic features and measurements in patients who underwent transcatheter pulmonary valve replacement with the Harmony TPV25 device despite a PP that predicted inadequate oversizing. RESULTS: This study included 22 patients. There were no unsuccessful implants or adverse valve-related events. Anatomic features varied, but all patients fit into 1 of 3 anatomic types characterized by differences in RVOT dimensions. Type 1 patients (n=9) had a long RVOT with a choke point and a wide main pulmonary artery. Type 2 patients (n=6) had a short RVOT that was pyramidal in shape, with no choke point, and extensive main pulmonary artery lengthening/expansion during systole. Type 3 patients (n=7) had a short, bulbous main pulmonary artery with a choke point and an open pulmonary artery bifurcation. CONCLUSIONS: Transcatheter pulmonary valve replacement with the Harmony valve is feasible in some patients whose PP fit analysis predicts inadequate oversizing. All cases in this series fit into 1 of 3 anatomic patterns, which are not identified in the screening report. Implanters must review cases individually to assess the feasibility of the implant.
Abstract 17934: Normal Doppler Hemodynamics of Pulmonary Valve Prostheses in Adults
Introduction: Pulmonary valve (PV) replacement is rare, so data regarding normal hemodynamics are limited. We sought to determine the normal Doppler-derived hemodynamic profiles of various PV prostheses (PVPs) in adults. Hypothesis: Doppler-derived hemodynamic profiles of normal PVPs will vary according to prosthesis type in adult patients. Methods: We performed a retrospective review of comprehensive two dimensional and Doppler echocardiographic examinations of 327 patients (median age, 35; range 18 -83 years) with normal PVPs performed early after implantation. Data were analyzed to determine mean±SD. Results: Parasternal short axis was the most commonly used window (96%) for assessment of PVPs. For the 327 PVPs, peak instantaneous gradient was 25±11 mmHg, mean systolic gradient was 13.1±6.1 mmHg, and mean right ventricular outflow tract velocity was 0.8±0.6 m/s. Results for selected variables analyzed by prosthesis type are listed in the Table. Pericardial prostheses had significantly lower peak gradient (21±10.1 mmHg; P=0.002) compared with porcine (25±9.7 mmHg), mechanical (26±16.6 mmHg), bovine venous (34±15.5 mmHg) and homograft PVPs (35±8.4 mm Hg). Conclusions: This is the largest series reporting normal Doppler-derived hemodynamic profiles of PVPs. This study establishes normative values for Doppler-derived variables for normal PVPs implanted in adults. Pericardial prostheses had the optimal hemodynamic profile in this patient population.