Back to Authors

Aboulhosn, Jamil

0000-0002-0209-9505

Mayo Clinic

University of California, Los Angeles

Citations 4

Transcatheter Pulmonary Valve Replacement With the Harmony Valve in Patients Who Do Not Meet Recommended Oversizing Criteria on the Screening Perimeter Plot
McElhinney, Doff B. , Gillespie, Matthew J. , Cabalka, Allison K. , Morray, Brian H. , Balzer, David T. , Qureshi, Athar M. , Hoskoppal, Arvind , Cabalka, Allison , Morray, Brian H , Qureshi, Athar M , Hoskoppal, Arvind K , Goldstein, Bryan H , McElhinney, Doff B , Aboulhosn, Jamil , Goldstein, Bryan H.

Circulation: Cardiovascular Interventions | April 12, 2024 | Volume: 17 | Issue: 5 | Pages: No page available

10.1161/circinterventions.123.013889 Get It

BACKGROUND: Anatomic selection for Harmony valve implant is determined with the aid of a screening report and perimeter plot (PP) that depicts the perimeter-derived radius along the right ventricular outflow tract (RVOT) and projects device oversizing. The PP provides an estimation of suitability for implant, but its sensitivity as a screening method is unknown. This study was performed to describe anatomic features and outcomes in patients who underwent Harmony TPV25 implant despite a PP that predicted inadequate oversizing. METHODS: We reviewed RVOT anatomic features and measurements in patients who underwent transcatheter pulmonary valve replacement with the Harmony TPV25 device despite a PP that predicted inadequate oversizing. RESULTS: This study included 22 patients. There were no unsuccessful implants or adverse valve-related events. Anatomic features varied, but all patients fit into 1 of 3 anatomic types characterized by differences in RVOT dimensions. Type 1 patients (n=9) had a long RVOT with a choke point and a wide main pulmonary artery. Type 2 patients (n=6) had a short RVOT that was pyramidal in shape, with no choke point, and extensive main pulmonary artery lengthening/expansion during systole. Type 3 patients (n=7) had a short, bulbous main pulmonary artery with a choke point and an open pulmonary artery bifurcation. CONCLUSIONS: Transcatheter pulmonary valve replacement with the Harmony valve is feasible in some patients whose PP fit analysis predicts inadequate oversizing. All cases in this series fit into 1 of 3 anatomic patterns, which are not identified in the screening report. Implanters must review cases individually to assess the feasibility of the implant.
Technical Recommendations for Computed Tomography Guidance of Intervention in the Right Ventricular Outflow Tract: Native RVOT, Conduits, and Bioprosthetic Valves
García, Santiago , Blanke, Phillip, Martin, Mary Hunt , Zahn, Evan M. , Crean, Andrew , Overman, David M. , Hanneman, Kate , Semple, Thomas , Overman, David, Hanneman, Kate , Han, Bo , Aboulhosn, Jamil , Hamilton-Craig, Christian R , Armstrong, Aimee K.

World Journal for Pediatric and Congenital Heart Surgery | August 30, 2023 | Volume: 14 | Issue: 6 | Pages: 761-791

10.1177/21501351231186898 Get It

This consensus document for the performance of cardiovascular computed tomography (CCT) to guide intervention in the right ventricular outflow tract (RVOT) in patients with congenital heart disease (CHD) was developed collaboratively by pediatric and adult interventionalists, surgeons, and cardiac imagers with expertise specific to this patient subset. The document summarizes definitions of RVOT dysfunction as assessed by multimodality imaging techniques and reviews existing consensus statements and guideline documents pertaining to indications for intervention. In the context of this background information, recommendations for CCT scan acquisition and a standardized approach for reporting prior to surgical or transcatheter pulmonary valve replacement are proposed and presented. It is the first Imaging for Intervention collaboration for CHD patients and encompasses imaging and reporting recommendations prior to both surgical and percutaneous pulmonary valve replacement.
Non-vitamin K antagonist oral anticoagulants in adults with a Fontan circulation: are they safe
Yang, Hayang , Veldtman, Gruschen , Bouma, Berto J. , Budts, Werner , Niwa, Koichiro , Meijboom, Folkert J., Egbe, Alexander C. , Schwerzmann, Markus , Broberg, Craig S. , Buber, Jonathan , Tsai, Shane, Post, Martijn C. , Mulder, Barbara J.M. , Egbe, Alexander Chima, Schwerzmann, Markus , Scognamiglio, Giancarlo , Morissens, Marielle , Polyzois, Ioannis , Greutmann, Matthias , Dijk, Arie P.J. van , Aboulhosn, Jamil , Bouma, Berto J

Open Heart | June 4, 2019 | Volume: 6 | Issue: 1 | Pages: e000985

10.1136/openhrt-2018-000985 Get It

Background In Fontan patients with atrial arrhythmias (AA), non-vitamin K antagonist oral anticoagulants(NOACs) have a class III recommendation according to the Pediatric & Congenital Electrophysiology Society (PACES)/Heart Rhythm Society (HRS) guideline in 2014, due to lack of data on outcomes as opposed to evidence of harm. To address this gap in data, we investigated the safety and efficacy of NOACs in adults with a Fontan circulation in a worldwide study. Methods This is an international multicentre prospective cohort study, using data from the NOTE ( n on-vitamin K antagonist o ral anticoagulants for t hrombo e mbolic prevention in patients with congenital heart disease) registry. The study population comprised consecutive adults with a Fontan circulation using NOACs. Follow-up took place at 6 months and yearly thereafter. The primary endpoints were thromboembolism and major bleeding. Secondary endpoint was minor bleeding. Results From April 2014 onward, 74 patients (mean age 32±10 years (range 18–68), 54% male) with a Fontan circulation using NOACs were included. During a median follow-up of 1.2 (IQR 0.8–2.0) years, three thromboembolic events (2.9 per 100 patient-years (95% CI 0.7 to 7.6)) and three major bleedings (2.9 per 100 patient-years (95% CI 0.7 to 7.6)) occurred in five atriopulmonary Fontan and one total cavopulmonary connection Fontan patients with AA. Fifteen patients experienced minor bleeding episodes (15.8 per 100 patient-years (95% CI 9.1 to 25.2)). In patients (n=37) using vitamin K antagonists (VKAs) prior to the initiation of NOAC, annual incidence of historical thromboembolic events and major bleeding were 2.4% (95% CI 0.4% to 7.4%) (n = 2) and 1.2% (95% CI 0.7% to 5.1%) (n = 1), respectively. Conclusions In this review of the largest Fontan cohort using NOACs with prospective follow-up, NOACs appear to be well tolerated and their efficacy and safety during short-term follow-up seem comparable to VKAs. Longer term data are required to confirm these promising short-term results.
Transcatheter Tricuspid Valve-in-Valve Implantation for the Treatment of Dysfunctional Surgical Bioprosthetic Valves
McElhinney, Doff B. , Eicken, Andreas , Boudjemline, Younès , Schubert, Stephan , Himbert, Dominique , Asnes, Jeremy D. , Salizzoni, Stefano , Bocks, Martin L. , Momenah, Tarek , Kim, Dennis W. , Schranz, Dietmar, Meadows, Jeffery , Thomson, John , Goldstein, Bryan H. , Crittendon, Ivory, Fagan, Thomas E. , Webb, John G. , Horlick, Eric , Delaney, Jeffrey W., Jones, Thomas K. , Shahanavaz, Shabana , Moretti, Carolina, Hainstock, Michael , Kenny, Damien , Berger, Felix , Rihal, Charanjit S. , Dvir, Danny , Cabalka, Allison K. , Aboulhosn, Jamil A, Cheatham, John P. , Momenah, Tarek S, Thomson, John D R, Hainstock, Michael R, Kenny, Damien P, Aboulhosn, Jamil , Cheatham, John P. , Rihal, Charanjit S. , McElhinney, Doff B , Goldstein, Bryan H

Circulation | March 19, 2016 | Volume: 133 | Issue: 16 | Pages: 1582-1593

10.1161/circulationaha.115.019353 Get It

Background— Off-label use of transcatheter aortic and pulmonary valve prostheses for tricuspid valve-in-valve implantation (TVIV) within dysfunctional surgical tricuspid valve (TV) bioprostheses has been described in small reports. Methods and Results— An international, multicenter registry was developed to collect data on TVIV cases. Patient-related factors, procedural details and outcomes, and follow-up data were analyzed. Valve-in-ring or heterotopic TV implantation procedures were not included. Data were collected on 156 patients with bioprosthetic TV dysfunction who underwent catheterization with planned TVIV. The median age was 40 years, and 71% of patients were in New York Heart Association class III or IV. Among 152 patients in whom TVIV was attempted with a Melody (n=94) or Sapien (n=58) valve, implantation was successful in 150, with few serious complications. After TVIV, both the TV inflow gradient and tricuspid regurgitation grade improved significantly. During follow-up (median, 13.3 months), 22 patients died, 5 within 30 days; all 22 patients were in New York Heart Association class III or IV, and 9 were hospitalized before TVIV. There were 10 TV reinterventions, and 3 other patients had significant recurrent TV dysfunction. At follow-up, 77% of patients were in New York Heart Association class I or II ( P <0.001 versus before TVIV). Outcomes did not differ according to surgical valve size or TVIV valve type. Conclusions— TVIV with commercially available transcatheter prostheses is technically and clinically successful in patients of various ages across a wide range of valve size. Although preimplantation clinical status was associated with outcome, many patients in New York Heart Association class III or IV at baseline improved. TVIV should be considered a viable option for treatment of failing TV bioprostheses.