Back to Authors

Dvir, Danny

https://orcid.org/0000-0002-4461-9089

Mayo Clinic

Hebrew University of Jerusalem

Citations 7

Predictors of Left Ventricular Outflow Tract Obstruction After Transcatheter Mitral Valve Replacement in Severe Mitral Annular Calcification: An Analysis of the Transcatheter Mitral Valve Replacement in Mitral Annular Calcification Global Registry
Sabbagh, Abdallah El , Al‐Hijji, Mohammed , Wang, Dee Dee , Eleid, Mackram F. , Ureña, Marina , Himbert, Dominique , Chakravarty, Tarun , Fang, Hao , Zahr, Firas , Dvir, Danny , Sardar, Muhammad , Cheema, Asim N. , Alnasser, Sami , Iyer, Vijay , Kaddissi, Georges, Webb, John G. , Makkar, Raj , Vahanian, Alec , Rihal, Charanjit S. , Eleid, Mackram F , Nejjari, Mohammed , Dvir, Danny , Rihal, Charanjit, Guerrero, Mayra E , Al-Hijji, Mohammed A , Wang, Dee Dee , Holzhey, David Michael , Pershad, Ashish , Nejjari, Mohammed , O’Neill, William W. , Rihal, Charanjit S. , Guerrero, Mayra

Circulation: Cardiovascular Interventions | October 19, 2021 | Volume: 14 | Issue: 10 | Pages: No page available

10.1161/circinterventions.121.010854 Get It

Background: Several studies have evaluated preprocedural imaging predictors of left ventricular outflow tract obstruction (LVOTO) after transcatheter mitral valve replacement. The patient cohorts in these studies were heterogeneous and included patients with transcatheter mitral valve replacement in failed bioprostheses, annuloplasty rings, and severe mitral annular calcification (MAC). The goal of this study was to evaluate predictors of LVOTO specific to patients undergoing valve-in-MAC. Methods: This study included patients with severe MAC who underwent valve-in-MAC and had optimal quality preprocedural multidetector row computed tomography scans eligible for retrospective analysis. Baseline demographic, echocardiographic, and procedural data on these patients were collected. multidetector row computed tomography parameters were analyzed for association with LVOTO, defined as increase in mean LVOT gradient by ≥10 mm Hg with accompanying hemodynamic instability. Results: Seventy-one patients with optimal preprocedural computed tomography scans were included in this study (mean age, 72.5±13.5 years), 9 of which developed LVOTO (all female). Baseline mean LVOT area, neo-LVOT area (145.3 versus 270.9 mm 2 ; P =0.006), indexed neo-LVOT area (90.1 versus 157.4; P =0.05), and virtual transcatheter heart valve to septum distance (3.1 versus 6.9 mm; P =0.002) were lower in the LVOTO group. Expected % LVOT area reduction was higher in the latter group (58.3 versus 42.7%; P =0.008). In the univariable analysis, the baseline mean LVOT area, neo-LVOT area, indexed neo-LVOT area, and valve to septum distance were all significantly associated with LVOTO. Conclusions: The systolic mean LVOT area, neo-LVOT area, indexed neo-LVOT, expected percentage LVOT area reduction, and the valve to septum distance were associated with LVOTO after valve-in-MAC.
Transcatheter Mitral Valve Replacement After Surgical Repair or Replacement
Simonato, Matheus , Ribeiro, Henrique Barbosa , Webb, John G. , Backer, Ole De , Villablanca, Pedro, Rihal, Charanjit S. , Eleid, Mackram F. , Kempfert, Jörg , Unbehaun, Axel , Erlebach, Magdalena , Casselman, Filip , Saia, Francesco , Ubben, Timm , Meincke, Felix , Napodano, Massimo, Codner, Pablo , Schöfer, Joachim, Pelletier, Marc , Cheung, Anson , Shuvy, Mony , Palma, José Honório , Duncan, Alison , Sinning, Jan-Malte, Arbel, Yaron , Weger, Arend de , Eltchaninoff, Hélène, Hemery, Thibault, Tchétché, Didier , Dumonteil, Nicolas, Rodés‐Cabau, Josep , Kim, Won-Keun, Spargias, Konstantinos, Kourkoveli, Panagiota, Ben‐Yehuda, Ori , Barbanti, Marco , Fiorina, Claudia , Thukkani, Arun K., Jones, Noah, Presbitero, Patrizia , Petronio, Anna Sonia , Champagnac, Didier , Rudolph, Tanja K. , Iadanza, Alessandro , Nombela‐Franco, Luis , Bonaros, Nikolaos , Kass, Malek , Amabile, Nicolas , Messina, Antonio , Andreas, Martin , Welsh, Robert C. , Schoels, Wolfgang , Hellig, Farrel, Windecker, Stephan , Stortecky, Stefan , Maisano, Francesco , Stone, Gregg W. , Dvir, Danny , Rihal, Charanjit, Eleid, Mackram, Nombela-Franco, Luis , Windecker, Stephan , Maisano, Francesco , De Backer, Ole , Whisenant, Brian K. , Kornowski, Ran , Guerrero, Mayra , Wijeysundera, Harindra C. , Søndergaard, Lars , Rihal, Charanjit S. , Adam, Matti , Montorfano, Matteo , Ancona, Marco , Gaia, Diego Felipe , Hildick-Smith, David , Veulemans, Verena , Sinning, Jan‐Malte, Testa, Luca , Landes, Uri , Kim, Won-Keun, Teles, Rui Campante , Mackensen, G. Burkhard , Allali, Abdelhakim , Bleiziffer, Sabine , Salizzoni, Stefano , Agrifoglio, Marco , Bruschi, Giuseppe , Chhatriwalla, Adnan K , Hirji, Sameer

Circulation | September 25, 2020 | Volume: 143 | Issue: 2 | Pages: 104-116

10.1161/circulationaha.120.049088 Get It

Background: Mitral valve-in-valve (ViV) and valve-in-ring (ViR) are alternatives to surgical reoperation in patients with recurrent mitral valve failure after previous surgical valve repair or replacement. Our aim was to perform a large-scale analysis examining midterm outcomes after mitral ViV and ViR. Methods: Patients undergoing mitral ViV and ViR were enrolled in the Valve-in-Valve International Data Registry. Cases were performed between March 2006 and March 2020. Clinical endpoints are reported according to the Mitral Valve Academic Research Consortium (MVARC) definitions. Significant residual mitral stenosis (MS) was defined as mean gradient ≥10 mm Hg and significant residual mitral regurgitation (MR) as ≥ moderate. Results: A total of 1079 patients (857 ViV, 222 ViR; mean age 73.5±12.5 years; 40.8% male) from 90 centers were included. Median STS-PROM score 8.6%; median clinical follow-up 492 days (interquartile range, 76–996); median echocardiographic follow-up for patients that survived 1 year was 772.5 days (interquartile range, 510–1211.75). Four-year Kaplan-Meier survival rate was 62.5% in ViV versus 49.5% for ViR ( P <0.001). Mean gradient across the mitral valve postprocedure was 5.7±2.8 mm Hg (≥5 mm Hg; 61.4% of patients). Significant residual MS occurred in 8.2% of the ViV and 12.0% of the ViR patients ( P =0.09). Significant residual MR was more common in ViR patients (16.6% versus 3.1%; P <0.001) and was associated with lower survival at 4 years (35.1% versus 61.6%; P =0.02). The rates of Mitral Valve Academic Research Consortium–defined device success were low for both procedures (39.4% total; 32.0% ViR versus 41.3% ViV; P =0.01), mostly related to having postprocedural mean gradient ≥5 mm Hg. Correlates for residual MS were smaller true internal diameter, younger age, and larger body mass index. The only correlate for residual MR was ViR. Significant residual MS (subhazard ratio, 4.67; 95% CI, 1.74–12.56; P =0.002) and significant residual MR (subhazard ratio, 7.88; 95% CI, 2.88–21.53; P <0.001) were both independently associated with repeat mitral valve replacement. Conclusions: Significant residual MS and/or MR were not infrequent after mitral ViV and ViR procedures and were both associated with a need for repeat valve replacement. Strategies to improve postprocedural hemodynamics in mitral ViV and ViR should be further explored.
Thirty-Day Outcomes of Transcatheter Mitral Valve Replacement for Degenerated Mitral Bioprostheses (Valve-in-Valve), Failed Surgical Rings (Valve-in-Ring), and Native Valve With Severe Mitral Annular Calcification (Valve-in-Mitral Annular Calcification) in
Vemulapalli, Sreekanth , Xiang, Qun, Wang, Dee Dee , Eleid, Mackram F. , Sandhu, Gurpreet S. , Salinger, Michael H., Russell, Hyde M., Kodali, Susheel , Dvir, Danny , Russo, Mark J., Fang, Kenith, Coylewright, Megan , Shah, Pinak , Babaliaros, Vasilis , Khan, Jaffar M. , Tommaso, Carl L. , Saucedo, Jorge , Makkar, Rajj, Mack, Michael J. , Holmes, David R. , Leon, Martin B. , Bapat, Vinayak , Thourani, Vinod H. , Rihal, Charanjit S. , O’Neill, William, Feldman, Ted , Douglas, Pamela S. , Eleid, Mackram, Cabalka, Allison K. , Rihal, Charanjit, Wang, Dee Dee , Douglas, Pamela S , Guerrero, Mayra , Greenbaum, Adam B. , George, Isaac , Whisenant, Brian K. , Pershad, Ashish , Shah, Pinak , Kar, Saibal , Makkar, Raj , Rihal, Charanjit S.

Circulation: Cardiovascular Interventions | March 6, 2020 | Volume: 13 | Issue: 3 | Pages: No page available

10.1161/circinterventions.119.008425 Get It

Background: Transcatheter mitral valve replacement using aortic transcatheter heart valves has recently become an alternative for patients with degenerated mitral bioprostheses, failed surgical repairs with annuloplasty rings or severe mitral annular calcification who are poor surgical candidates. Outcomes of these procedures are collected in the Society of Thoracic Surgeons/American College of Cardiology/Transcatheter Valve Therapy Registry. A comprehensive analysis of mitral valve-in-valve (MViV), mitral valve-in-ring (MViR), and valve-in-mitral annular calcification (ViMAC) outcomes has not been performed. We sought to evaluate short-term outcomes of early experience with MViV, MViR, and ViMAC in the United States. Methods: Retrospective analysis of data from the Society of Thoracic Surgeons/American College of Cardiology Transcatheter Valve Therapy Registry. Results: Nine hundred three high-risk patients (median Society of Thoracic Surgeons score 10%) underwent MViV (n=680), MViR (n=123), or ViMAC (n=100) between March 2013 and June 2017 at 172 hospitals. Median age was 75 years, 59.2% female. Technical and procedural success were higher in MViV. Left ventricular outflow tract obstruction occurred more frequently with ViMAC (ViMAC=10%, MViR=4.9%, MViV=0.7%; P <0.001). In-hospital mortality (MViV=6.3%, MViR=9%, ViMAC=18%; P =0.004) and 30-day mortality (MViV=8.1%, MViR=11.5%, ViMAC=21.8%; P =0.003) were higher in ViMAC. At 30-day follow-up, median mean mitral valve gradient was 7 mm Hg, most patients (96.7%) had mitral regurgitation grade ≤1 (+) and were in New York Heart Association class I to II (81.7%). Conclusions: MViV using aortic balloon-expandable transcatheter heart valves is associated with a low complication rate, a 30-day mortality lower than predicted by the Society of Thoracic Surgeons score, and superior short-term outcomes than MViR and ViMAC. At 30 days, patients in all groups experienced improvement of symptoms, and valve performance remained stable. Registration: URL: https://www.clinicaltrials.gov ; Unique identifier: NCT02245763.
Mortality prediction after transcatheter treatment of failed bioprosthetic aortic valves utilizing various international scoring systems: Insights from the Valve‐in‐Valve International Data (VIVID)
Aziz, Mina, Simonato, Matheus , Webb, John G. , Abdel‐Wahab, Mohamed , McElhinney, Doff B. , Duncan, Alison , Tchétché, Didier , Barbanti, Marco , Petronio, Anna Sonia , Maisano, Francesco , Ribeiro, Vasco Gama , Gaia, Diego Felipe , Rana, Ruhina , Kočka, Viktor , Mathur, Moses , Wijeysundera, Harindra C. , Hellig, Farrel, Bekeredjian, Raffi , Rihal, Charanjit S. , Dvir, Danny , Rihal, Charanjit, Maisano, Francesco , McElhinney, Doff B , Aziz, Mina, Nissen, Henrik , Rihal, Charanjit S. , Duffy, Stephen James

Catheterization and Cardiovascular Interventions | August 7, 2018 | Volume: 92 | Issue: 6 | Pages: 1163-1170

10.1002/ccd.27714 Get It

Abstract Background Transcatheter Aortic Valve Implantation (TAVI) is commonly used to deploy new bioprosthetic valves inside degenerated surgically implanted aortic valves in high risk patients. The three scoring systems used to assess risk of postprocedural mortality are: Logistic EuroSCORE (LES), EuroSCORE II (ES II), and Society of Thoracic Surgeons (STS). Objective The purpose of this study is to analyze the accuracy of LES, ES II, and STS in estimating all‐cause mortality after transcatheter aortic valve‐in‐valve (ViV) implantations, which was not assessed before. Methods Using the Valve‐in‐Valve International Data (VIVID) registry, a total of 1,550 patients from 110 centers were included. The study compared the observed 30‐day overall mortality vs. the respective predicted mortalities calculated by risk scores. The accuracy of prediction models was assessed based on calibration and discrimination. Results Observed mortality at 30 days was 5.3%, while average expected mortalities by LES, ES II and STS were 29.49 (± 17.2), 14.59 (± 8.6), and 9.61 (± 8.51), respectively. All three risk scores overestimated 30‐day mortality with ratios of 0.176 (95% CI 0.138–0.214), 0.342 (95% CI 0.264–0.419), and 0.536 (95% CI 0.421–0.651), respectively. 30‐day mortality ROC curves demonstrated that ES II had the largest AUC at 0.722, followed by STS at 0.704, and LES at 0.698. Conclusions All three scores overestimated mortality at 30 days with ES II showing the highest predictability compared to LES and STS; and therefore, should be recommended for ViV procedures. There is a need for a dedicated scoring system for patients undergoing ViV interventions.
Standardized Definition of Structural Valve Degeneration for Surgical and Transcatheter Bioprosthetic Aortic Valves
Dvir, Danny , Bourguignon, Thierry , Rosenhek, Raphaël , Webb, John G. , Treede, Hendrik , Enriquez‐Sarano, Maurice , Feldman, Ted , Wijeysundera, Harindra C. , Topilsky, Yan , Aupart, Michel, Reardon, Michael J. , Szeto, Wilson Y. , Gammie, James S. , Yoganathan, Ajit P. , Arbel, Yaron , Borger, Michael A. , Simonato, Matheus , Reisman, Mark, Makkar, Raj , Abizaid, Alexandre , Dahle, Gry , Aldea, Gabriel S. , Leipsic, Jonathon , Pîbarot, Philippe , Moat, Neil, Mack, Michael J. , Leon, Martin B. , Topilsky, Yan , Sarano, Maurice E, Pibarot, Phillippe , Enriquez-Sarano, Maurice , Otto, Catherine M , Hahn, Rebecca T , Mackensen, G. Burkhard , Kornowski, Ran , McCabe, James M , Kappetein, A. Pieter , Topilsky, Yan , Reardon, Michael J , Abizaid, Alexandre

Circulation | January 22, 2018 | Volume: 137 | Issue: 4 | Pages: 388-399

10.1161/circulationaha.117.030729 Get It

Bioprostheses are prone to structural valve degeneration, resulting in limited long-term durability. A significant challenge when comparing the durability of different types of bioprostheses is the lack of a standardized terminology for the definition of a degenerated valve. This issue becomes especially important when we try to compare the degeneration rate of surgically inserted and transcatheter bioprosthetic valves. This document, by the VIVID (Valve-in-Valve International Data), proposes practical and standardized definitions of valve degeneration and provides recommendations for the timing of clinical and imaging follow-up assessments accordingly. Its goal is to improve the quality of research and clinical care for patients with deteriorated bioprostheses by providing objective and strict criteria that can be utilized in future clinical trials. We hope that the adoption of these criteria by both the cardiological and surgical communities will lead to improved comparability and interpretation of durability analyses.
Transcatheter valve implantation for right atrium‐to‐right ventricle conduit obstruction or regurgitation after modified Björk–fontan procedure
Horlick, Eric , Eicken, Andreas , Asnes, Jeremy D. , Bocks, Martin L. , Boudjemline, Younès , Fagan, Thomas E. , Schubert, Stephan , Mahadevan, Vaikom S. , Dvir, Danny , Osten, Mark , McElhinney, Doff B. , Cabalka, Allison K. , Shah, Ashish H. , McElhinney, Doff B

Catheterization and Cardiovascular Interventions | July 28, 2016 | Volume: 89 | Issue: 2 | Pages: 298-305

10.1002/ccd.26648 Get It

BackgroundThe most common reason for reintervention after a Björk modification of the Fontan procedure, in which the right ventricle (RV) is incorporated into the pulmonary circulation by connecting the right atrial (RA) appendage to the RV directly or with an extra‐anatomic graft, is obstruction or regurgitation of the RA–RV connection. Transcatheter implantation of a valved stent is an appealing option for the treatment of RA–RV conduit dysfunction in these patients. In the present study, we assessed early and intermediate results after transcatheter valve implantation within an obstructed or regurgitant RA–RV modified Fontan pathway.MethodsThrough a retrospective multicenter registry, we collected data from 16 patients with a modified Fontan circulation who were treated with percutaneous Melody or Sapien valve implantation for dysfunction of an extra‐anatomic RA–RV conduit or valve.ResultsAll patients had successful and uncomplicated implantation of a Melody (n = 15) or Sapien 3 (n = 1) valve with hemodynamic and, in most cases, clinical improvement. During a median follow‐up of 3.3 years, 3 patients died of cardiovascular causes unrelated to the procedure or the valve, and no major valve dysfunction was observed.ConclusionPercutaneous transcatheter valve deployment to treat a dysfunctional RA–RV connection after a Björk modification of the Fontan procedure is a viable alternative to surgery, with low procedural risk, and appears to offer good early and intermediate results.© 2016 Wiley Periodicals, Inc.
Transcatheter Tricuspid Valve-in-Valve Implantation for the Treatment of Dysfunctional Surgical Bioprosthetic Valves
McElhinney, Doff B. , Eicken, Andreas , Boudjemline, Younès , Schubert, Stephan , Himbert, Dominique , Asnes, Jeremy D. , Salizzoni, Stefano , Bocks, Martin L. , Momenah, Tarek , Kim, Dennis W. , Schranz, Dietmar, Meadows, Jeffery , Thomson, John , Goldstein, Bryan H. , Crittendon, Ivory, Fagan, Thomas E. , Webb, John G. , Horlick, Eric , Delaney, Jeffrey W., Jones, Thomas K. , Shahanavaz, Shabana , Moretti, Carolina, Hainstock, Michael , Kenny, Damien , Berger, Felix , Rihal, Charanjit S. , Dvir, Danny , Cabalka, Allison K. , Aboulhosn, Jamil A, Cheatham, John P. , Momenah, Tarek S, Thomson, John D R, Hainstock, Michael R, Kenny, Damien P, Aboulhosn, Jamil , Cheatham, John P. , Rihal, Charanjit S. , McElhinney, Doff B , Goldstein, Bryan H

Circulation | March 19, 2016 | Volume: 133 | Issue: 16 | Pages: 1582-1593

10.1161/circulationaha.115.019353 Get It

Background— Off-label use of transcatheter aortic and pulmonary valve prostheses for tricuspid valve-in-valve implantation (TVIV) within dysfunctional surgical tricuspid valve (TV) bioprostheses has been described in small reports. Methods and Results— An international, multicenter registry was developed to collect data on TVIV cases. Patient-related factors, procedural details and outcomes, and follow-up data were analyzed. Valve-in-ring or heterotopic TV implantation procedures were not included. Data were collected on 156 patients with bioprosthetic TV dysfunction who underwent catheterization with planned TVIV. The median age was 40 years, and 71% of patients were in New York Heart Association class III or IV. Among 152 patients in whom TVIV was attempted with a Melody (n=94) or Sapien (n=58) valve, implantation was successful in 150, with few serious complications. After TVIV, both the TV inflow gradient and tricuspid regurgitation grade improved significantly. During follow-up (median, 13.3 months), 22 patients died, 5 within 30 days; all 22 patients were in New York Heart Association class III or IV, and 9 were hospitalized before TVIV. There were 10 TV reinterventions, and 3 other patients had significant recurrent TV dysfunction. At follow-up, 77% of patients were in New York Heart Association class I or II ( P <0.001 versus before TVIV). Outcomes did not differ according to surgical valve size or TVIV valve type. Conclusions— TVIV with commercially available transcatheter prostheses is technically and clinically successful in patients of various ages across a wide range of valve size. Although preimplantation clinical status was associated with outcome, many patients in New York Heart Association class III or IV at baseline improved. TVIV should be considered a viable option for treatment of failing TV bioprostheses.