Back to Authors

Wang, Dee Dee

0000-0002-5784-9924

Mayo Clinic

Center for Structural Heart Disease, Henry Ford Hospital, Detroit, MI, USA.

Citations 10

Cardiac Computed Tomography for Prosthetic Heart Valve Assessment. An Expert Consensus Document of the Society of Cardiovascular Computed Tomography (SCCT), the American College of Cardiology (ACC), the European Soci
Budde, Ricardo P.J. , Faure, M. , Cremer, Paul , Feuchtner, Gudrun , Gonzales, Holly M, Kiefer, Todd L., Leipsic, Jonathon , Nieman, Koen , Williamson, Eric E. , Ballmoos, Moritz C. Wyler von , Salgado, Rodrigo , Faure, Marguerite E , Abbara, Suhny , Alkadhi, Hatem , Cremer, Paul C , Feuchtner, Gudrun M , Gonzales, Holly M , Leipsic, Jonathan , Nieman, Koen , Revels, Jonathan W , Wang, Dee Dee , Williamson, Eric , Salgado, Rodrigo , Budde, Ricardo Peter Jurgen , Revels, Jonathan , Wang, Dee Dee , Zwischenberger, Brittany A.

Radiology: Cardiothoracic Imaging | June 17, 2025 | Volume: 7 | Issue: 3 | Pages: No page available

10.1148/ryct.250231 Get It

Prosthetic heart valve (PHV) dysfunction is increasingly seen due to the increase in the number of PHV that are being implanted worldwide. Cardiac CT imaging has emerged as a valuable tool to assess PHVs and determine the cause of dysfunction. This consensus document first summarizes the available techniques for PHV assessment. Then the use of CT in PHV (dys)function assessment is discussed in detail including consensus statements for correct indications and patient selection for CT assessment of PHVs, image acquisition, reconstruction and measurement protocols and how to interpret and report the CT findings for specific types of PHV dysfunction. This article was published in Journal of Cardiovascular Computed Tomography, Budde RPJ et al, Cardiac computed tomography for prosthetic heart valve assessment: An expert consensus document of the Society of Cardiovascular Computed Tomography (SCCT), the American College of Cardiology (ACC), the European Society of Cardiovascular Radiology (ESCR), the North American Society for Cardiovascular Imaging (NASCI), the Radiological Society of North America (RSNA), the Society for Cardiovascular Angiography & Interventions (SCAI), and the Society of Thoracic Surgeons (STS). The articles are identical except for minor stylistic and spelling differences in keeping with each journal’s style. Either citation may be used when referencing this document. © 2025 Society of Cardiovascular Computed Tomography. Published by Elsevier Inc. on behalf of the Society of Cardiovascular Computed Tomography. This is an open access article under the CC BY-NC-ND license ( http://creativecommons.org/licenses/by-nc-nd/4.0/ ). Keywords: Computed Tomography, Valve, Cardiac, Imaging, Dysfunction, Prosthetic
The impact of pulmonary hypertension on outcomes of transcatheter mitral valve replacement in mitral annular calcification
Cajigas, Héctor , Kaptzan, Tatiana, Lewis, Bradley R., El‐Sabbagh, Abdallah, Al‐Hijji, Mohammed , Eleid, Mackram F. , Wang, Dee Dee , Eng, Marvin H. , Kodali, Susheel , Chakravarty, Tarun , O’Hair, Daniel, Jones, Noah, Makkar, Raj , Reisman, Mark, Leon, Martin B. , Rihal, Charanjit S. , Cajigas, Hector R , Eleid, Mackram F , Wang, Dee Dee , Pershad, Ashish , Rihal, Charanjit, Guerrero, Mayra E , Al-Hijji, Mohammed A , Alkhouli, Mohamad , George, Isaac , Pershad, Ashish , O’Neill, William W. , Rihal, Charanjit S. , Guerrero, Mayra

Catheterization and Cardiovascular Interventions | January 12, 2022 | Volume: 99 | Issue: 5 | Pages: 1647-1658

10.1002/ccd.30057 Get It

AbstractObjectivesTo assess the impact of pulmonary hypertension (PH) on outcomes of patients with severe mitral annular calcification (MAC) undergoing transcatheter mitral valve replacement (TMVR).BackgroundPH is associated with poor outcomes after mitral valve surgery. Whether the presence of PH in patients with MAC undergoing (TMVR) is associated with poor outcomes, is unknown.MethodsRetrospective evaluation of 116 patients from 51 centers in 11 countries who underwent TMVR with valve in mitral annular calcification (ViMAC) using balloon‐expandable aortic transcatheter valves (THVs) from September 2012 to March 2017. Pulmonary artery systolic blood pressure (PASP) by echocardiogram was available in 90 patients. The subjects were stratified based on PASP: No PH = PASP ≤35 mmHg (n = 11); mild to moderate PH = PASP 36–49 mmHg (n = 21) and severe PH = PASP ≥50 mmHg (n = 58). Clinical, procedural, and echocardiographic outcomes were assessed.ResultsMean age was 72.7 (±12.8) years, 59 (65.6%) were female, Society of Thoracic Surgeons score was 15.8 + 11.8% and 90.0% where in New York Heart Association (NYHA) class III–IV. There was no significant difference in all‐cause mortality at 30 days (no PH = 27.3%, mild–moderate PH = 19.0%, severe PH = 31.6%; p = 0.55) or at 1 year (no PH = 54.5%, mild–moderate PH = 38.1%, severe PH = 56.1%; p = 0.36). No difference in adverse events, NYHA class or amount of residual mitral regurgitation at 1 year were observed between the groups.ConclusionThis study suggests that the presence of PH in patients with predominantly mitral stenosis with MAC undergoing TMVR does not impact mortality or adverse events. Further studies are needed to fully understand the effect of PH in this group of patients.
Sex-Based Differences in Outcomes With Percutaneous Transcatheter Repair of Mitral Regurgitation With the MitraClip System: Transcatheter Valve Therapy Registry From 2011 to 2017
Villablanca, Pedro , Vemulapalli, Sreekanth , Stebbins, Amanda , Dai, Dadi, So, Chak-Yu , Eng, Marvin H. , Wang, Dee Dee , Frisoli, Tiberio , Lee, James , Kang, Guson , Ibrahim, Homam , Staniloae, Cezar , Gaba, Prakriti , Lemor, Alejandro , Finn, Matthew , Leon, Martin B. , Villablanca, Pedro A , Lee, James C , Staniloae, Cezar , Lemor, Alejandro , Ramakrishna, Harish , Shah, Binita , Wang, Dee Dee , Szerlip, Molly , Williams, Mathew , O’Neill, William W. , Shah, Binita

Circulation: Cardiovascular Interventions | November 16, 2021 | Volume: 14 | Issue: 11 | Pages: No page available

10.1161/circinterventions.120.009374 Get It

Background: Women have a higher rate of adverse events after mitral valve surgery. We sought to evaluate whether outcomes after transcatheter edge-to-edge repair intervention by sex have similar trends to mitral valve surgery. Methods: The primary outcome was 1-year major adverse events defined as a composite of all-cause mortality, stroke, and any bleeding in the overall study cohort. Patients who underwent transcatheter edge-to-edge repair for mitral regurgitation with the MitraClip system in the Society of Thoracic Surgery/American College of Cardiology Transcatheter Valve Therapy registry were evaluated. Linked administrative claims from the Centers for Medicare and Medicaid Services were used to evaluate 1-year clinical outcomes. Associations between sex and outcomes were evaluated using a multivariable logistic regression model for in-hospital outcomes and Cox model for 1-year outcomes. Results: From November 2013 to March 2017, 5295 patients, 47.6% (n=2523) of whom were female, underwent transcatheter edge-to-edge repair. Females were less likely to have >1 clip implanted ( P <0.001) and had a lower adjusted odds ratio of device success (adjusted odds ratio, 0.78 [95% CI, 0.67–0.90]), driven by lower odds of residual mitral gradient <5 mm Hg (adjusted odds ratio, 0.54 [CI, 0.46–0.63]) when compared with males. At 1-year follow-up, the primary outcome did not differ by sex. Female sex was associated with lower adjusted 1-year risk of all-cause mortality (adjusted hazard ratio, 0.80 [CI, 0.68–0.94]), but the adjusted 1-year risk of stroke and any bleeding did not differ by sex. Conclusions: No difference in composite outcome of all-cause mortality, stroke, and any bleeding was observed between females and males. Adjusted 1-year all-cause mortality was lower in females compared with males.
Predictors of Left Ventricular Outflow Tract Obstruction After Transcatheter Mitral Valve Replacement in Severe Mitral Annular Calcification: An Analysis of the Transcatheter Mitral Valve Replacement in Mitral Annular Calcification Global Registry
Sabbagh, Abdallah El , Al‐Hijji, Mohammed , Wang, Dee Dee , Eleid, Mackram F. , Ureña, Marina , Himbert, Dominique , Chakravarty, Tarun , Fang, Hao , Zahr, Firas , Dvir, Danny , Sardar, Muhammad , Cheema, Asim N. , Alnasser, Sami , Iyer, Vijay , Kaddissi, Georges, Webb, John G. , Makkar, Raj , Vahanian, Alec , Rihal, Charanjit S. , Eleid, Mackram F , Nejjari, Mohammed , Dvir, Danny , Rihal, Charanjit, Guerrero, Mayra E , Al-Hijji, Mohammed A , Wang, Dee Dee , Holzhey, David Michael , Pershad, Ashish , Nejjari, Mohammed , O’Neill, William W. , Rihal, Charanjit S. , Guerrero, Mayra

Circulation: Cardiovascular Interventions | October 19, 2021 | Volume: 14 | Issue: 10 | Pages: No page available

10.1161/circinterventions.121.010854 Get It

Background: Several studies have evaluated preprocedural imaging predictors of left ventricular outflow tract obstruction (LVOTO) after transcatheter mitral valve replacement. The patient cohorts in these studies were heterogeneous and included patients with transcatheter mitral valve replacement in failed bioprostheses, annuloplasty rings, and severe mitral annular calcification (MAC). The goal of this study was to evaluate predictors of LVOTO specific to patients undergoing valve-in-MAC. Methods: This study included patients with severe MAC who underwent valve-in-MAC and had optimal quality preprocedural multidetector row computed tomography scans eligible for retrospective analysis. Baseline demographic, echocardiographic, and procedural data on these patients were collected. multidetector row computed tomography parameters were analyzed for association with LVOTO, defined as increase in mean LVOT gradient by ≥10 mm Hg with accompanying hemodynamic instability. Results: Seventy-one patients with optimal preprocedural computed tomography scans were included in this study (mean age, 72.5±13.5 years), 9 of which developed LVOTO (all female). Baseline mean LVOT area, neo-LVOT area (145.3 versus 270.9 mm 2 ; P =0.006), indexed neo-LVOT area (90.1 versus 157.4; P =0.05), and virtual transcatheter heart valve to septum distance (3.1 versus 6.9 mm; P =0.002) were lower in the LVOTO group. Expected % LVOT area reduction was higher in the latter group (58.3 versus 42.7%; P =0.008). In the univariable analysis, the baseline mean LVOT area, neo-LVOT area, indexed neo-LVOT area, and valve to septum distance were all significantly associated with LVOTO. Conclusions: The systolic mean LVOT area, neo-LVOT area, indexed neo-LVOT, expected percentage LVOT area reduction, and the valve to septum distance were associated with LVOTO after valve-in-MAC.
Short‐ and mid‐term outcomes in percutaneous mitral valve replacement using balloon expandable valves
Eng, Marvin H. , Kargoli, Faraj , Wang, Dee Dee , Frisoli, Tiberio , Villablanca, Pedro, Nemeh, Hassan, Guerrero, Mayra , O’Neill, Brian , Wyman, Janet , Guerrero, Mayra E , O'Neill, Brian P , Wang, Dee Dee , Lee, James C. , Villablanca, Pedro, Greenbaum, Adam B. , O’Neill, William W.

Catheterization and Cardiovascular Interventions | June 9, 2021 | Volume: 98 | Issue: 6 | Pages: 1193-1203

10.1002/ccd.29783 Get It

AbstractBackgroundDue to elevated surgical risk, transcatheter mitral valve replacement (TMVR) is used as an alternative for treating failed bioprosthetic valves, annuloplasty repairs and mitral annular calcification (MAC). We report the procedural and longitudinal outcomes for each subtype: Mitral valve‐in‐valve (MVIV), mitral valve‐in‐ring (MViR), and valve‐in‐MAC (ViMAC).MethodsConsecutive patients undergoing TMVR from October 2013 to December 2019 were assessed. Patients at high risk for left ventricular outflow tract obstruction had either alcohol septal ablation or intentional laceration of the anterior leaflet (LAMPOON).ResultsEight‐eight patients underwent TMVR; 38 MViV, 31 MViR, and 19 ViMAC procedures were performed. The median Society of Thoracic Surgery 30‐day predicted risk of mortality was 8.2% (IQR 5.2, 19.9) for all. Sapien 3 (78%) and transseptal access (98%) were utilized in most cases. All‐cause in‐hospital mortality, technical, and procedural success were 8%, 83%, and 66% respectively. Median follow up was 1.4 years (IQR 0.5–2.9 years) and overall survival was 40% at 4 years. Differential survival rates were observed with MViV doing the best, followed by MViR and ViMAC having a <20% survival at 4 years. After adjusting for co‐variates, MViV procedure was the strongest predictor of survival (HR 0.24 [95% CI 0.079–0.7]).ConclusionTMVR is performed in at high‐risk patients with attenuated long‐term survival. MViV has the best success and survival rate, but long‐term survival in MViR and ViMAC is guarded.
Real world outcomes using 20 mm balloon expandable SAPIEN 3/ultra valves compared to larger valves (23, 26, and 29 mm)–a propensity matched analysis
Eng, Marvin H. , Abbas, Amr E. , Wang, Dee Dee , Eleid, Mackram F. , Wang, Dee Dee , Eleid, Mackram F , Hahn, Rebecca T , Lee, James , O’Neill, William W.

Catheterization and Cardiovascular Interventions | May 13, 2021 | Volume: 98 | Issue: 6 | Pages: 1185-1192

10.1002/ccd.29756 Get It

AbstractObjective/BackgroundSmall balloon expandable valves have higher echocardiographic transvalvular gradients and rates of prosthesis‐patient mismatch (PPM) compared to larger valves. However, the impact of these echocardiographic findings on clinical outcomes is unknown. We sought to determine the clinical outcomes of 20 mm SAPIEN 3 (S3 BEV) compared to larger S3 BEV in relation to echocardiographic hemodynamics.MethodsUsing the STS/ACC transcatheter valve registry, we performed a propensity‐matched comparison of patients undergoing treatment of native aortic valve stenosis using transfemoral, balloon‐expandable implantation of 20 mm and ≥ 23 mm S3 BEVs. Baseline and procedure characteristics, echocardiographic variables and survival were analyzed. Multivariable logistic regression was used to identify predictors of 1‐year mortality.ResultsAfter propensity matching of the 20 mm and ≥ 23 mm SAPIEN 3 valves, 3,931 pairs with comparable baseline characteristics were identified. Small valves were associated with significantly higher echocardiographic gradients at discharge (15.7 ± 7.1 mmHg vs. 11.7 ± 5.5 mmHg, p < 0.0001) and severe PPM rates (21.5% vs. 9.7%, p < 0.0001). There was no significant difference in 1‐year all‐cause mortality (20 mm: 13.0% vs. ≥23 mm: 12.7%, p = 0.72) or other major adverse event rates and outcomes between the two cohorts. Based on a multivariable analysis, elevated discharge mean gradient (>20 mmHg), severe PPM and the use of 20 mm versus ≥23 mm were not independent predictors of 1‐year mortality.ConclusionSAPIEN 3 20 mm valves were associated with higher echocardiographic gradients, and severe PPM rates compared to larger valves but these factors were not associated with significant differences in 1‐year all‐cause mortality or rehospitalization.
Thirty-Day Outcomes of Transcatheter Mitral Valve Replacement for Degenerated Mitral Bioprostheses (Valve-in-Valve), Failed Surgical Rings (Valve-in-Ring), and Native Valve With Severe Mitral Annular Calcification (Valve-in-Mitral Annular Calcification) in
Vemulapalli, Sreekanth , Xiang, Qun, Wang, Dee Dee , Eleid, Mackram F. , Sandhu, Gurpreet S. , Salinger, Michael H., Russell, Hyde M., Kodali, Susheel , Dvir, Danny , Russo, Mark J., Fang, Kenith, Coylewright, Megan , Shah, Pinak , Babaliaros, Vasilis , Khan, Jaffar M. , Tommaso, Carl L. , Saucedo, Jorge , Makkar, Rajj, Mack, Michael J. , Holmes, David R. , Leon, Martin B. , Bapat, Vinayak , Thourani, Vinod H. , Rihal, Charanjit S. , O’Neill, William, Feldman, Ted , Douglas, Pamela S. , Eleid, Mackram, Cabalka, Allison K. , Rihal, Charanjit, Wang, Dee Dee , Douglas, Pamela S , Guerrero, Mayra , Greenbaum, Adam B. , George, Isaac , Whisenant, Brian K. , Pershad, Ashish , Shah, Pinak , Kar, Saibal , Makkar, Raj , Rihal, Charanjit S.

Circulation: Cardiovascular Interventions | March 6, 2020 | Volume: 13 | Issue: 3 | Pages: No page available

10.1161/circinterventions.119.008425 Get It

Background: Transcatheter mitral valve replacement using aortic transcatheter heart valves has recently become an alternative for patients with degenerated mitral bioprostheses, failed surgical repairs with annuloplasty rings or severe mitral annular calcification who are poor surgical candidates. Outcomes of these procedures are collected in the Society of Thoracic Surgeons/American College of Cardiology/Transcatheter Valve Therapy Registry. A comprehensive analysis of mitral valve-in-valve (MViV), mitral valve-in-ring (MViR), and valve-in-mitral annular calcification (ViMAC) outcomes has not been performed. We sought to evaluate short-term outcomes of early experience with MViV, MViR, and ViMAC in the United States. Methods: Retrospective analysis of data from the Society of Thoracic Surgeons/American College of Cardiology Transcatheter Valve Therapy Registry. Results: Nine hundred three high-risk patients (median Society of Thoracic Surgeons score 10%) underwent MViV (n=680), MViR (n=123), or ViMAC (n=100) between March 2013 and June 2017 at 172 hospitals. Median age was 75 years, 59.2% female. Technical and procedural success were higher in MViV. Left ventricular outflow tract obstruction occurred more frequently with ViMAC (ViMAC=10%, MViR=4.9%, MViV=0.7%; P <0.001). In-hospital mortality (MViV=6.3%, MViR=9%, ViMAC=18%; P =0.004) and 30-day mortality (MViV=8.1%, MViR=11.5%, ViMAC=21.8%; P =0.003) were higher in ViMAC. At 30-day follow-up, median mean mitral valve gradient was 7 mm Hg, most patients (96.7%) had mitral regurgitation grade ≤1 (+) and were in New York Heart Association class I to II (81.7%). Conclusions: MViV using aortic balloon-expandable transcatheter heart valves is associated with a low complication rate, a 30-day mortality lower than predicted by the Society of Thoracic Surgeons score, and superior short-term outcomes than MViR and ViMAC. At 30 days, patients in all groups experienced improvement of symptoms, and valve performance remained stable. Registration: URL: https://www.clinicaltrials.gov ; Unique identifier: NCT02245763.
Complete percutaneous apical access and closure: Short and intermediate term outcomes
Eng, Marvin H. , Kherallah, Riyad , Guerrero, Mayra , Frisoli, Tiberio , Villablanca, Pedro , Wang, Dee Dee , Wyman, Janet , Wang, Dee Dee , Guerrero, Mayra E , Greenbaum, Adam B. , Lee, James , O’Neill, William W.

Catheterization and Cardiovascular Interventions | January 20, 2020 | Volume: 96 | Issue: 2 | Pages: 481-487

10.1002/ccd.28731 Get It

AbstractObjectivesTo examine the safety of utilizing transapical access during structural interventions.BackgroundComplex interventions of the mitral or aortic region sometimes require coaxial forces to orient and deliver devices. Apical access can provide coaxial countertraction for either transseptal or retrograde aortic access. This manuscript describes the single center experience of small bore transapical access.MethodsRetrospective review of cases from 2013 to 2018 at Henry Ford Hospital was performed. Patient demographics and procedure characteristics were abstracted to describe the safety of transapical access using small bore sheaths.ResultsA total 21 cases were performed at Henry Ford, most of them for transcatheter mitral valve replacement (81%). The mean sheath size used was 4.7 ± 0.9 Fr and protamine was used at the end of 57% of cases. All patients received nitinol‐based plugs, 80.1% were from the Amplatz Duct Occluder II type. Four major complications related apical puncture occurred, two pericardial effusions, two hemothorax. Over a median follow time of 430 days (IQR 50–652) a total of five deaths occurred, two related to the procedure and three late deaths with a median time of 362 days (range 205–628 days). No deaths were associated with transapical access. Echocardiographic follow up did not detect any late structural complications from occluder devices.ConclusionsTransapical access and closure with nitinol‐based devices is feasible and facilitates complex interventions where coaxial forces are need for device delivery and alignment. The most common complication is bleeding and this should be kept in perspective when treating high‐risk patients.
Association of peripheral artery disease with in‐hospital outcomes after endovascular transcatheter aortic valve replacement
Mohananey, Divyanshu , Villablanca, Pedro , Ando, Tomo , Wang, Dee Dee , Wiley, José , Eng, Marvin H. , Shah, Binita , Saucedo, Jorge , Bhatt, Deepak L. , Ando, Tomo , Wang, Dee Dee , Eng, Marvin , Ramakrishna, Harish , Bhatt, Deepak L , Shah, Binita , Gupta, Tanush , Ranka, Sagar , Bhatia, Nirmanmoh , Adegbala, Oluwole Muyiwa , Kalra, Ankur , O’Neill, William W.

Catheterization and Cardiovascular Interventions | April 26, 2019 | Volume: 94 | Issue: 2 | Pages: 249-255

10.1002/ccd.28310 Get It

AbstractObjectivesThe aim of this study was to determine the prevalence of peripheral artery disease (PAD) and its association with in‐hospital outcomes after endovascular transcatheter aortic valve replacement (EV‐TAVR).BackgroundTAVR is an established treatment for patients at prohibitive, high, or intermediate surgical risk. PAD is a significant comorbidity in the determination of surgical risk. However, data on association of PAD with outcomes after EV‐TAVR are limited.MethodsPatients in the National Inpatient Sample who underwent EV‐TAVR between January 1, 2012 and September 30, 2015 were evaluated. The primary outcome was in‐hospital mortality.ResultsA total of 51,685 patients underwent EV‐TAVR during the study period. Of these, 12,740 (24.6%) had a coexisting diagnosis of PAD. The adjusted odds for in‐hospital mortality [OR 1.08 (95% CI 0.83–1.41)], permanent pacemaker implantation [OR 0.98 (0.85–1.14)], conversion to open aortic valve replacement [OR 1.05 (0.49–2.26)], or acute myocardial infarction [OR 1.31(0.99–1.71)] were not different in patients with versus without PAD. However, patients with PAD had greater adjusted odds of vascular complications [OR 1.80 (1.50–2.16)], major bleeding [OR 1.20 (1.09–1.34)], acute kidney injury (AKI) [OR 1.19 (1.05–1.36)], cardiac complications [aOR 1.21 (1.01–1.44)], and stroke [OR 1.39(1.10–1.75)] compared with patients without PAD. Length of stay (LOS) was significantly longer for patients with PAD [7.23 (0.14) days vs. 7.11 (0.1) days, p < 0.001].ConclusionOf patients undergoing EV‐TAVR, ~25% have coexisting PAD. PAD was not associated with increased risk of in‐hospital mortality but was associated with higher risk of vascular complications, major bleeding, AKI, stroke, cardiac complications, and longer LOS.
Imaging in patients with severe mitral annular calcification: insights from a multicentre experience using transatrial balloon-expandable valve replacement
Praz, Fabien , Khalique, Omar , Lee, Raymond , Wu, Isaac Y. , Russell, Hyde M., Wang, Dee Dee , Veeragandham, Ramesh, Islam, Ashequl , Deaton, David W., Eudailey, Kyle W. , Akkoc, Deniz, Kantor, Alex , Wang, Catherine , Tang, Diane, Park, Joongheum S, Leung, Diana, Nazif, Tamim , Vahl, Torsten , Kodali, Susheel , Leon, Martin B. , Takayama, Hiroo , Bapat, Vinayak , Borger, Michael A. , Wang, Dee Dee , Praz, Fabien , Guerrero, Mayra , Kaneko, Tsuyoshi , Tang, Diane C H, Hahn, Rebecca T , George, Isaac , Takayama, Hiroo

European Heart Journal - Cardiovascular Imaging | March 6, 2019 | Volume: 20 | Issue: 12 | Pages: 1395-1406

10.1093/ehjci/jez050 Get It

Abstract Aims To investigate valve sizing and the haemodynamic relevance of the predicted left ventricular outflow tract (LVOT) in patients with mitral annular calcification (MAC) undergoing transatrial transcatheter valve implantation (THV). Methods and results In total, 21 patients undergoing transatrial THV, multiplanar reconstruction (MPR), maximum intensity projection (MIP), and cubic spline interpolation (CSI) were compared for MA sizing during diastole. In addition, predicted neo-LVOT areas were measured in 18 patients and correlated with the post-procedural haemodynamic dimensions. The procedure was successful in all patients (100%). Concomitant aortic valve replacement was performed in eight patients (43%) (AVR group). Sizing using MPR and MIP yielded comparable results in terms of area, perimeter, and diameter, whereas the dimensions obtained with CSI were systematically smaller. The simulated mean systolic neo-LVOT area was 133.4 ± 64.2 mm2 with an anticipated relative LVOT area reduction (neo-LVOT area/LVOT area × 100) of 59.3 ± 14.7%. The systolic relative LVOT area reduction, but not the absolute neo-LVOT area, was found to predict the peak (r = 0.69; P = 0.002) and mean (r = 0.65; P = 0.004) post-operative aortic gradient in the overall population as well as separately in the AVR (peak: r = 0.91; P = 0.002/mean: r = 0.85; P = 0.002) and no-AVR (peak: r = 0.89; P = 0.003/mean: r = 0.72; P = 0.008) groups. Conclusion In patients with severe MAC undergoing transatrial transcatheter valve implantation, MPR, and MIP yielded comparable annular dimensions, while values obtained with CSI tended to be systematically smaller. Mitral annular area and the average annular diameter appear to be reliable parameters for valve selection. Simulated relative LVOT reduction was found to predict the post-procedural aortic gradients.