Sex-Based Differences in Outcomes With Percutaneous Transcatheter Repair of Mitral Regurgitation With the MitraClip System: Transcatheter Valve Therapy Registry From 2011 to 2017
Background: Women have a higher rate of adverse events after mitral valve surgery. We sought to evaluate whether outcomes after transcatheter edge-to-edge repair intervention by sex have similar trends to mitral valve surgery. Methods: The primary outcome was 1-year major adverse events defined as a composite of all-cause mortality, stroke, and any bleeding in the overall study cohort. Patients who underwent transcatheter edge-to-edge repair for mitral regurgitation with the MitraClip system in the Society of Thoracic Surgery/American College of Cardiology Transcatheter Valve Therapy registry were evaluated. Linked administrative claims from the Centers for Medicare and Medicaid Services were used to evaluate 1-year clinical outcomes. Associations between sex and outcomes were evaluated using a multivariable logistic regression model for in-hospital outcomes and Cox model for 1-year outcomes. Results: From November 2013 to March 2017, 5295 patients, 47.6% (n=2523) of whom were female, underwent transcatheter edge-to-edge repair. Females were less likely to have >1 clip implanted ( P <0.001) and had a lower adjusted odds ratio of device success (adjusted odds ratio, 0.78 [95% CI, 0.67–0.90]), driven by lower odds of residual mitral gradient <5 mm Hg (adjusted odds ratio, 0.54 [CI, 0.46–0.63]) when compared with males. At 1-year follow-up, the primary outcome did not differ by sex. Female sex was associated with lower adjusted 1-year risk of all-cause mortality (adjusted hazard ratio, 0.80 [CI, 0.68–0.94]), but the adjusted 1-year risk of stroke and any bleeding did not differ by sex. Conclusions: No difference in composite outcome of all-cause mortality, stroke, and any bleeding was observed between females and males. Adjusted 1-year all-cause mortality was lower in females compared with males.
Complete percutaneous apical access and closure: Short and intermediate term outcomes
AbstractObjectivesTo examine the safety of utilizing transapical access during structural interventions.BackgroundComplex interventions of the mitral or aortic region sometimes require coaxial forces to orient and deliver devices. Apical access can provide coaxial countertraction for either transseptal or retrograde aortic access. This manuscript describes the single center experience of small bore transapical access.MethodsRetrospective review of cases from 2013 to 2018 at Henry Ford Hospital was performed. Patient demographics and procedure characteristics were abstracted to describe the safety of transapical access using small bore sheaths.ResultsA total 21 cases were performed at Henry Ford, most of them for transcatheter mitral valve replacement (81%). The mean sheath size used was 4.7 ± 0.9 Fr and protamine was used at the end of 57% of cases. All patients received nitinol‐based plugs, 80.1% were from the Amplatz Duct Occluder II type. Four major complications related apical puncture occurred, two pericardial effusions, two hemothorax. Over a median follow time of 430 days (IQR 50–652) a total of five deaths occurred, two related to the procedure and three late deaths with a median time of 362 days (range 205–628 days). No deaths were associated with transapical access. Echocardiographic follow up did not detect any late structural complications from occluder devices.ConclusionsTransapical access and closure with nitinol‐based devices is feasible and facilitates complex interventions where coaxial forces are need for device delivery and alignment. The most common complication is bleeding and this should be kept in perspective when treating high‐risk patients.
Association of peripheral artery disease with in‐hospital outcomes after endovascular transcatheter aortic valve replacement
AbstractObjectivesThe aim of this study was to determine the prevalence of peripheral artery disease (PAD) and its association with in‐hospital outcomes after endovascular transcatheter aortic valve replacement (EV‐TAVR).BackgroundTAVR is an established treatment for patients at prohibitive, high, or intermediate surgical risk. PAD is a significant comorbidity in the determination of surgical risk. However, data on association of PAD with outcomes after EV‐TAVR are limited.MethodsPatients in the National Inpatient Sample who underwent EV‐TAVR between January 1, 2012 and September 30, 2015 were evaluated. The primary outcome was in‐hospital mortality.ResultsA total of 51,685 patients underwent EV‐TAVR during the study period. Of these, 12,740 (24.6%) had a coexisting diagnosis of PAD. The adjusted odds for in‐hospital mortality [OR 1.08 (95% CI 0.83–1.41)], permanent pacemaker implantation [OR 0.98 (0.85–1.14)], conversion to open aortic valve replacement [OR 1.05 (0.49–2.26)], or acute myocardial infarction [OR 1.31(0.99–1.71)] were not different in patients with versus without PAD. However, patients with PAD had greater adjusted odds of vascular complications [OR 1.80 (1.50–2.16)], major bleeding [OR 1.20 (1.09–1.34)], acute kidney injury (AKI) [OR 1.19 (1.05–1.36)], cardiac complications [aOR 1.21 (1.01–1.44)], and stroke [OR 1.39(1.10–1.75)] compared with patients without PAD. Length of stay (LOS) was significantly longer for patients with PAD [7.23 (0.14) days vs. 7.11 (0.1) days, p < 0.001].ConclusionOf patients undergoing EV‐TAVR, ~25% have coexisting PAD. PAD was not associated with increased risk of in‐hospital mortality but was associated with higher risk of vascular complications, major bleeding, AKI, stroke, cardiac complications, and longer LOS.
Transcatheter Versus Surgical Aortic Valve Replacement in Patients With Prior Coronary Artery Bypass Grafting
Background— A significant proportion of patients requiring aortic valve replacement (AVR) have undergone prior coronary artery bypass grafting (CABG). Reoperative heart surgery is associated with increased risk. Data on relative utilization and comparative outcomes of transcatheter (TAVR) versus surgical AVR (SAVR) in patients with prior CABG are limited. Methods and Results— We queried the 2012 to 2014 National Inpatient Sample databases to identify isolated AVR hospitalizations in adults with prior CABG. In-hospital outcomes of TAVR versus SAVR were compared using propensity-matched analysis. Of 147 395 AVRs, 15 055 (10.2%) were in patients with prior CABG. The number of TAVRs in patients with prior CABG increased from 1615 in 2012 to 4400 in 2014, whereas the number of SAVRs decreased from 2285 to 1895 ( P trend <0.001). There were 3880 records in each group in the matched cohort. Compared with SAVR, TAVR was associated with similar in-hospital mortality (2.3% versus 2.4%; P =0.71) but lower incidence of myocardial infarction (1.5% versus 3.4%; P <0.001), stroke (1.4% versus 2.7%; P <0.001), bleeding complications (10.6% versus 24.6%; P <0.001), and acute kidney injury (16.2% versus 19.3%; P <0.001). Requirement for prior permanent pacemaker was higher in the TAVR cohort, whereas the incidence of vascular complications and acute kidney injury requiring dialysis was similar in the 2 groups. Average length of stay was shorter in patients undergoing TAVR. Conclusions— TAVR is being increasingly used as the preferred modality of AVR in patients with prior CABG. Compared with SAVR, TAVR is associated with similar in-hospital mortality but lower rates of in-hospital complications in this important subset of patients.
Comparison of local versus general anesthesia in patients undergoing transcatheter aortic valve replacement: A meta‐analysis
AbstractBackgroundTranscatheter aortic valve replacement (TAVR) is typically performed under general anesthesia (GA). However, there is increasing data supporting the safety of performing TAVR under local anesthesia/conscious sedation (LA). We performed a meta‐analysis to gain better understanding of the safety and efficacy of LA versus GA in patients with severe aortic stenosis undergoing TAVR.Methods and ResultsWe comprehensively searched EMBASE, PubMed, and Web of Science. Effect sizes were summarized using risk ratios (RRs) difference of the mean (DM), and 95% CIs (confidence intervals) for dichotomous and continuous variables respectively. Twenty‐six studies and 10,572 patients were included in the meta‐analysis. The use of LA for TAVR was associated with lower overall 30‐day mortality (RR, 0.73; 95% CI, 0.57–0.93; P = 0.01), use of inotropic/vasopressor drugs (RR, 0.45; 95% CI, 0.28–0.72; P < 0.001), hospital length of stay (LOS) (DM, −2.09; 95% CI, −3.02 to −1.16; P < 0.001), intensive care unit LOS (DM, −0.18; 95% CI, −0.31 to −0.04; P = 0.01), procedure time (DM, −25.02; 95% CI, −32.70 to −17.35; P < 0.001); and fluoroscopy time (DM, −1.63; 95% CI, −3.02 to −0.24; P = 0.02). No differences were observed between LA and GA for stroke, cardiovascular mortality, myocardial infarction, permanent pacemaker implantation, acute kidney injury, paravalvular leak, vascular complications, major bleeding, procedural success, conduction abnormalities, and annular rupture.ConclusionOur meta‐analysis suggests that use of LA for TAVR is associated with a lower 30‐day mortality, shorter procedure time, fluoroscopy time, ICU LOS, hospital length of stay, and reduced need for inotropic support.
Extracorporeal Membrane Oxygenation in Severe Influenza Infection with Respiratory Failure: A Systematic Review and Meta-analysis
Introduction: Extracorporeal membrane oxygenation (ECMO) has been extensively used for potentially reversible acute respiratory failure associated with severe influenza A (H1N1) pneumonia; however, it remains an expensive, resource-intensive therapy, with a high associated mortality. This systematic review and meta-analysis aims to summarize and pool outcomes data available in the published literature to guide clinical decision-making and further research. Methods: We conducted a systematic search of MEDLINE (1966 to April 15, 2015), EMBASE (1980 to April 15, 2015), CENTRAL, and Google Scholar for patients with severe H1N1 pneumonia and respiratory failure who received ECMO. The study validity was appraised by Newcastle–Ottawa Scale. The primary outcome was all-cause mortality. The secondary outcomes were duration of ECMO therapy, mechanical ventilation, and Intensive Care Unit (ICU) length of stay. Results: Of 698 abstracts screened and 142 full-text articles reviewed, we included 13 studies with a total of 494 patients receiving ECMO in our final review and meta-analysis. The study validity was satisfactory. The overall mortality was 37.1% (95% confidence interval: 30–45%) limited by underlying heterogeneity ( I 2 = 65%, P value of Q statistic = 0.006). The median duration for ECMO was 10 days, mechanical ventilation was 19 days, and ICU length of stay was 33 days. Exploratory meta-regression did not identify any statistically significant moderator of mortality ( P < 0.05), except for the duration of pre-ECMO mechanical ventilation in days (coefficient 0.19, standard error: 0.09, Z = 2.01, P < 0.04, R 2 = 0.16). The visual inspection of funnel plots did not suggest the presence of publication bias. Conclusions: ECMO therapy may be used as an adjunct or salvage therapy for severe H1N1 pneumonia with respiratory failure. It is associated with a prolonged duration of ventilator support, ICU length of stay, and high mortality. Initiating ECMO early once the patient has been instituted on mechanical ventilation may result in improved survival.