Back to Authors

Gupta, Tanush

Mayo Clinic

University of Vermont Medical Center

Citations 2

Abstract 4370319: Early Safety Signals and Common Pitfalls of the TriClip™ System for Transcatheter Tricuspid Valve Repair: Analysis of FDA's MAUDE Database
Gupta, Lovish , Gulati, Arvind , Futela, Pragyat , Khanna, Tejasvini, Aneja, Ashish , Gupta, Tanush, Kowlgi, Gurukripa N. , Gupta, Tanush , Chatterjee, Arka

Circulation | November 3, 2025 | Volume: 152 | Issue: Suppl_3 | Pages: No page available

10.1161/circ.152.suppl_3.4370319 Get It

Background: Tricuspid regurgitation (TR) can lead to right ventricular failure (RVF) and poor clinical outcomes. The TriClip™ G4 transcatheter edge-to-edge repair (TEER) system has shown improved outcomes in TR patients and received FDA approval on April 2, 2024. The FDA’s Manufacturer and User Facility Device Experience (MAUDE) database collects mandatory manufacturer reports and voluntary provider reports on device-related complications. Methods: We retrieved all TriClip™-related adverse events from the MAUDE database post-FDA approval, excluding duplicate entries and literature reviews. After removing 47 literature reviews and 36 duplicate reports, 443 unique adverse event reports from 407 procedures (some with multiple events) were analyzed between April 2, 2024, and January 31, 2025. Results: SLDA (Single Leaflet Device Attachment) was the most frequent complication, occurring in 204 cases (Figure 1). Detached leaflets included septal (105 cases), anterior (46), posterior (27), lateral (3), multiple (2), and unreported. Contributing factors included poor imaging, tethered leaflet, clip-clip interaction, dense chordae, large right atrium (RA) or gap size, pacer lead, or prior valve intervention. Persistent TR was a common consequence. SLDA was addressed with additional clips in 77 cases (18 requiring multiple clips), no intervention in 55 cases (13 with significant residual TR), repeat TriClip procedures in 16 cases, and surgical repair in 4 cases. Other complications included partial SLDA (23 cases), clip deployment or gripper malfunctions (68), chordal entanglement (41), leaflet entanglement (3), and clip migration/embolization (6). Migrated clips were found in the RA, right atrial appendage, cardiac vein, or pulmonary artery; three required snare retrieval, and three were left in place. Triclip Steerable Guide Catheter (TSGC) malfunctions, such as leaks, loss of column support, and blockages, were reported in 29 cases, with 27 requiring replacement. Miscellaneous events included residual TR, leaflet grasping issues, F-knob malfunction, lock line jams, and TSGC entanglement. Clip opening during Establishing Final Arm Angle (EFAA) occurred in 25 cases, and leaflet puncture in 15 cases, with one requiring surgical intervention. Conclusion: SLDA was the most frequently reported complication following TriClip™ approval, with some cases leading to severe outcomes. Continued surveillance is crucial to assess long-term safety and optimize procedural strategies.
Transcatheter Versus Surgical Aortic Valve Replacement in Patients With Prior Coronary Artery Bypass Grafting
Khera, Sahil , Villablanca, Pedro , Taub, Cynthia C. , Kleiman, Neal S. , Weisz, Giora, Inglessis, Ignacio, Rihal, Charanjit S. , García, Mario J. , Bhatt, Deepak L. , Gupta, Tanush, Kolte, Dhaval, Kalra, Ankur , Elmariah, Sammy, Bhatt, Deepak L , Gupta, Tanush , Kolte, Dhaval , Goel, Kashish , Aronow, Herbert D. , Abbott, J. Dawn , Fonarow, Gregg C. , Elmariah, Sammy , Rihal, Charanjit S.

Circulation: Cardiovascular Interventions | April 11, 2018 | Volume: 11 | Issue: 4 | Pages: No page available

10.1161/circinterventions.117.006179 Get It

Background— A significant proportion of patients requiring aortic valve replacement (AVR) have undergone prior coronary artery bypass grafting (CABG). Reoperative heart surgery is associated with increased risk. Data on relative utilization and comparative outcomes of transcatheter (TAVR) versus surgical AVR (SAVR) in patients with prior CABG are limited. Methods and Results— We queried the 2012 to 2014 National Inpatient Sample databases to identify isolated AVR hospitalizations in adults with prior CABG. In-hospital outcomes of TAVR versus SAVR were compared using propensity-matched analysis. Of 147 395 AVRs, 15 055 (10.2%) were in patients with prior CABG. The number of TAVRs in patients with prior CABG increased from 1615 in 2012 to 4400 in 2014, whereas the number of SAVRs decreased from 2285 to 1895 ( P trend <0.001). There were 3880 records in each group in the matched cohort. Compared with SAVR, TAVR was associated with similar in-hospital mortality (2.3% versus 2.4%; P =0.71) but lower incidence of myocardial infarction (1.5% versus 3.4%; P <0.001), stroke (1.4% versus 2.7%; P <0.001), bleeding complications (10.6% versus 24.6%; P <0.001), and acute kidney injury (16.2% versus 19.3%; P <0.001). Requirement for prior permanent pacemaker was higher in the TAVR cohort, whereas the incidence of vascular complications and acute kidney injury requiring dialysis was similar in the 2 groups. Average length of stay was shorter in patients undergoing TAVR. Conclusions— TAVR is being increasingly used as the preferred modality of AVR in patients with prior CABG. Compared with SAVR, TAVR is associated with similar in-hospital mortality but lower rates of in-hospital complications in this important subset of patients.