Back to Authors

Williamson, Eric

0000-0002-2066-9612

Mayo Clinic

Department of Radiology, Mayo Clinic, Rochester, MN, USA.

Citations 6

First-in-Human Safety and Feasibility of Nodal and Pedal MR Lymphangiography with Gadopiclenol
Thompson, Scott M. , Collins, Jeremy D. , Bendel, Emily C. , Reisenauer, Christopher J., Jundt, Michael C., Yalҫin, Müge, Favazza, Christopher , Lu, Aiming , McDonald, Robert J. , Williamson, Eric E. , Stinson, Eric G. , In, MyungHo, Favazza, Christopher P , Messina, Steven A , Collins, Jeremy , Williamson, Eric , Thompson, Scott , Bendel, Emily , In, Myung-Ho , Jundt, Michael C., In, Myung‐Ho , Messina, Steven A.

Radiology: Cardiothoracic Imaging | July 2, 2026 | Volume: 8 | Issue: 4 | Pages: No page available

10.1148/ryct.260067 Get It

Dynamic gadopiclenol-enhanced nodal and pedal MR lymphangiography was safe, with no adverse events, and feasible for imaging peripheral and central conducting lymphatic anatomy.
Deep Learning–based Monoenergetic Imaging for Calcified Coronary Stenosis Assessment at Energy-integrating Detector CT
Chang, Shaojie , Koons, Emily K. , Gong, Hao , Thorne, Jamison E. , Williamson, Eric E. , Foley, Thomas A. , McCollough, Cynthia H., Leng, Shuai, McCollough, Cynthia H. , Leng, Shuai , McCollough, Cynthia H , Leng, Shuai , Williamson, Eric , Thorne, Jamison E , Gong, Hao

Radiology: Cardiothoracic Imaging | March 19, 2026 | Volume: 8 | Issue: 2 | Pages: No page available

10.1148/ryct.250230 Get It

A deep learning–based neural network enabled virtual monoenergetic imaging at energy-integrating detector CT, reduced blooming artifacts, and improved stenosis assessment in heavily calcified coronary plaques, with performance comparable to ultrahigh-resolution photon-counting detector CT.
Cardiac Computed Tomography for Prosthetic Heart Valve Assessment. An Expert Consensus Document of the Society of Cardiovascular Computed Tomography (SCCT), the American College of Cardiology (ACC), the European Soci
Budde, Ricardo P.J. , Faure, M. , Cremer, Paul , Feuchtner, Gudrun , Gonzales, Holly M, Kiefer, Todd L., Leipsic, Jonathon , Nieman, Koen , Williamson, Eric E. , Ballmoos, Moritz C. Wyler von , Salgado, Rodrigo , Faure, Marguerite E , Abbara, Suhny , Alkadhi, Hatem , Cremer, Paul C , Feuchtner, Gudrun M , Gonzales, Holly M , Leipsic, Jonathan , Nieman, Koen , Revels, Jonathan W , Wang, Dee Dee , Williamson, Eric , Salgado, Rodrigo , Budde, Ricardo Peter Jurgen , Revels, Jonathan , Wang, Dee Dee , Zwischenberger, Brittany A.

Radiology: Cardiothoracic Imaging | June 17, 2025 | Volume: 7 | Issue: 3 | Pages: No page available

10.1148/ryct.250231 Get It

Prosthetic heart valve (PHV) dysfunction is increasingly seen due to the increase in the number of PHV that are being implanted worldwide. Cardiac CT imaging has emerged as a valuable tool to assess PHVs and determine the cause of dysfunction. This consensus document first summarizes the available techniques for PHV assessment. Then the use of CT in PHV (dys)function assessment is discussed in detail including consensus statements for correct indications and patient selection for CT assessment of PHVs, image acquisition, reconstruction and measurement protocols and how to interpret and report the CT findings for specific types of PHV dysfunction. This article was published in Journal of Cardiovascular Computed Tomography, Budde RPJ et al, Cardiac computed tomography for prosthetic heart valve assessment: An expert consensus document of the Society of Cardiovascular Computed Tomography (SCCT), the American College of Cardiology (ACC), the European Society of Cardiovascular Radiology (ESCR), the North American Society for Cardiovascular Imaging (NASCI), the Radiological Society of North America (RSNA), the Society for Cardiovascular Angiography & Interventions (SCAI), and the Society of Thoracic Surgeons (STS). The articles are identical except for minor stylistic and spelling differences in keeping with each journal’s style. Either citation may be used when referencing this document. © 2025 Society of Cardiovascular Computed Tomography. Published by Elsevier Inc. on behalf of the Society of Cardiovascular Computed Tomography. This is an open access article under the CC BY-NC-ND license ( http://creativecommons.org/licenses/by-nc-nd/4.0/ ). Keywords: Computed Tomography, Valve, Cardiac, Imaging, Dysfunction, Prosthetic
Comparison of Photon-counting Detector and Energy-integrating Detector CT for Visual Estimation of Coronary Percent Luminal Stenosis
McCollough, Cynthia H. , Bois, John P. , Winfree, Tim N., Carter, Rickey E. , Rajendran, Kishore , Williamson, Eric E. , Thorne, Jamison E. , Leng, Shuai , Rajiah, Prabhakar , Winfree, Tim N , Carter, Rickey E , Rajendran, Kishore , Williamson, Eric , Thorne, Jamison E , Leng, Shuai , McCollough, Cynthia H , Rajiah, Prabhakar

Radiology | December 5, 2023 | Volume: 309 | Issue: 3 | Pages: No page available

10.1148/radiol.230853 Get It

Utility of CT and MRI in Tricuspid Valve Interventions
Reddy, Prajwal , Baliyan, Vinit , Hedgire, Sandeep, Foley, Thomas A. , Williamson, Eric E. , Eleid, Mackram F. , Rajiah, Prabhakar , Reddy, Prajwal , Hedgire, Sandeep S , Foley, Thomas , Williamson, Eric , Rajiah, Prabhakar

RadioGraphics | June 29, 2023 | Volume: 43 | Issue: 7 | Pages: No page available

10.1148/rg.220153 Get It