RF Noise Artifacts From a High Frequency Spinal Cord Stimulation System: A Retrospective Imaging Cohort With Illustrative Cases
Stinson, Eric G. , Hubbard, Abby, Kleinow, Jenna E. , Kramer, Emily A., Trzasko, Joshua D. , Shu, Yunhong , Edmonson, Heidi A. , Hubbard, Abby J, Hubbard, Abby J.

Journal of Magnetic Resonance Imaging | July 6, 2026 | Volume: No volume available | Issue: No issue available | Pages: No page available

10.1002/jmri.70394 Get It

ABSTRACT Unexpected RF noise artifact “followed” a patient with an implanted spinal cord stimulator to multiple MR systems. Subsequent testing and clinical scanning showed no artifact, implying that the artifact originated from the implanted device. MR exams ( n = 173) performed over a two‐year period in patients ( n = 122) who had implanted spinal cord stimulators from the same manufacturer were reviewed for artifacts and device models. RF noise artifacts were observed in ~50% of exams in patients with a specific model of spinal cord stimulator, but only ~1%–8% of exams in other models from the same manufacturer. We hope that by describing this artifact, health care professionals can avoid service costs and scheduling delays.
First-in-Human Safety and Feasibility of Nodal and Pedal MR Lymphangiography with Gadopiclenol
Thompson, Scott M. , Collins, Jeremy D. , Bendel, Emily C. , Reisenauer, Christopher J., Jundt, Michael C., Yalҫin, Müge, Favazza, Christopher , Lu, Aiming , McDonald, Robert J. , Williamson, Eric E. , Stinson, Eric G. , In, MyungHo, Favazza, Christopher P , Messina, Steven A , Collins, Jeremy , Williamson, Eric , Thompson, Scott , Bendel, Emily , In, Myung-Ho , Jundt, Michael C., In, Myung‐Ho , Messina, Steven A.

Radiology: Cardiothoracic Imaging | July 2, 2026 | Volume: 8 | Issue: 4 | Pages: No page available

10.1148/ryct.260067 Get It

Dynamic gadopiclenol-enhanced nodal and pedal MR lymphangiography was safe, with no adverse events, and feasible for imaging peripheral and central conducting lymphatic anatomy.
Modified acquisition strategy for reduced motion artifact in super resolution FSE multislice MRI: Application to prostate
Kargar, Soudabeh , Borisch, Eric A. , Froemming, Adam T. , Grimm, Roger C., King, Bernard F., Stinson, Eric G. , Riederer, Stephen J. , Kawashima, Akira

Magnetic Resonance in Medicine | May 18, 2020 | Volume: 84 | Issue: 5 | Pages: 2537-2550

10.1002/mrm.28315 Get It

PurposeTo reduce slice‐to‐slice motion effects in multislice ‐weighted fast‐spin‐echo ( FSE) imaging, manifest as “scalloping” in reformats, by modification of the acquisition strategy and to show applicability in prostate MRI.Methods FSE images of contiguous or overlapping slices are typically acquired using multiple passes in which each pass is comprised of multiple slices with slice‐to‐slice gaps. Combination of slices from all passes provides the desired sampling. For enhancement of through‐plane resolution with super resolution or for reformatting into other orientations, subtle ≈1 mm motion between passes can cause objectionable “scalloping” artifact. Here we address this by subdivision of each pass into multiple segments. Interleaving of segments from the multiple passes causes all slices to be acquired over substantially the same time, reducing pass‐to‐pass motion effects. This was implemented in acquiring 78 overlapped FSE axial slices and studied in phantoms and in 14 prostate MRI patients. Super‐resolution axial images and sagittal reformats from the original and new segmented acquisitions were evaluated by 3 uroradiologists.ResultsFor all criteria of sagittal reformats, the segmented acquisition was statistically superior to the original. For all sharpness criteria of axial images, although the trend preferred the original acquisition, the difference was not significant. For artifact in axial images, the segmented acquisition was significantly superior.ConclusionsFor prostate MRI the new segmented acquisition significantly reduces the scalloping motion artifact that can be present in reformats due to long time lags between the acquisition of adjacent or overlapped slices while retaining image sharpness in the acquired axial slices.
Use of kZ‐space for high through‐plane resolution in multislice MRI: Application to prostate
Froemming, Adam T. , Grimm, Roger C., King, Bernard F., Stinson, Eric G. , Riederer, Stephen J. , Kargar, Soudabeh , Borisch, Eric A. , Kawashima, Akira

Magnetic Resonance in Medicine | March 7, 2019 | Volume: 81 | Issue: 6 | Pages: 3691-3704

10.1002/mrm.27691 Get It

PurposeThe goal of this work is to demonstrate 1 mm through‐plane resolution in multislice T2SE MRI using k‐space processing of overlapping slices and show applicability in prostate MRI.MethodsMultiple overlapped slices are acquired and Fourier transformed in the slice‐select direction. The slice profile is incorporated into a Tikhonov‐regularized reconstruction. Through‐plane resolution is tested in a resolution phantom. An anthropomorphic prostate phantom is used to study the SNR, and results are compared with theoretical prediction. The proposed method is tested in 16 patients indicated for clinical prostate MRI who gave written informed consent as overseen by our IRB. The “proposed” vs. “reference” multislice images are compared using multiple evaluation criteria for through‐plane resolution.ResultsThe modulation transfer function (MTF) plots of the resolution phantom show good modulation at frequency 0.5 lp/mm, demonstrating 1 mm through‐plane resolution restoration. The SNR measurements experimentally match the theoretically predicted values. The radiological evaluation shows that the proposed method is superior to the reference method for five criteria of sharpness but inferior with respect to artifacts.ConclusionsIn conjunction with overlapped slices a k‐space‐based reconstruction approach can be used to improve through‐plane resolution in multislice T2SE MRI. 1 mm resolution is demonstrated from 3.2 mm thick slices. The in vivo results from prostate MRI show improved sharpness when compared to the standard multislice method.
Time‐resolved contrast‐enhanced MR angiography with single‐echo Dixon fat suppression
Stinson, Eric G. , Trzasko, Joshua D. , Glockner, James F., Young, Phillip M. , Riederer, Stephen J. , Campeau, Norbert G. , Huston, John

Magnetic Resonance in Medicine | February 28, 2018 | Volume: 80 | Issue: 4 | Pages: 1556-1567

10.1002/mrm.27152 Get It

PurposeDixon‐based fat suppression has recently gained interest for dynamic contrast‐enhanced MRI, but multi‐echo techniques require longer scan times and reduce temporal resolution compared to single‐echo alternatives without fat suppression. The purpose of this work is to demonstrate accelerated single‐echo Dixon imaging with high spatial and temporal resolution.Theory and MethodsReal‐valued water and fat images can be obtained from a single measurement if the shared initial phase and that due to are assumed known a priori. An expression for simultaneous sensitivity encoding (SENSE) unfolding and fat‐water separation is derived for the general undersampling case, and simplified under the special case of uniform Cartesian undersampling. In vivo experiments were performed in extremities and brain with SENSE acceleration factors of up to R = 8.ResultsSingle‐echo Dixon reconstruction of highly undersampled data was successfully demonstrated. Dynamic contrast‐enhanced water and fat images provided high spatial and temporal resolution dynamic images with image update times shorter than previous single‐echo Dixon work.ConclusionTime‐resolved contrast‐enhanced MRI with single‐echo Dixon fat suppression shows high image quality, improved vessel delineation, and reduced sensitivity to motion when compared to time‐subtraction methods.
Technical Aspects of Contrast-enhanced MR Angiography: Current Status and New Applications
Riederer, Stephen J. , Stinson, Eric G. , Weavers, Paul T.

Magnetic Resonance in Medical Sciences | August 30, 2017 | Volume: 17 | Issue: 1 | Pages: 3-12

10.2463/mrms.rev.2017-0053 Get It

Dual echo Dixon imaging with a constrained phase signal model and graph cuts reconstruction
Stinson, Eric G. , Trzasko, Joshua D. , Riederer, Stephen J. , Fletcher, Joel G.

Magnetic Resonance in Medicine | February 2, 2017 | Volume: 78 | Issue: 6 | Pages: 2203-2215

10.1002/mrm.26620 Get It

PurposeThe purpose of this work is to derive and demonstrate constrained‐phase dual‐echo Dixon imaging within a maximum likelihood framework solved with a regularized graph‐cuts‐guided optimization.Theory and MethodsDual‐echo Dixon reconstruction is fundamentally underdetermined; however, adopting a constrained‐phase signal model reduces the number of unknowns and the nonlinear problem can be solved under a maximum likelihood framework. Period shifts in the field map (manifesting as fat/water signal swaps) must also be corrected. Here, a regularized cost function promotes a smooth field map and is solved with a graph‐cuts‐guided greedy binary optimization. The reconstruction shown here is compared to two other prevalent Dixon reconstructions in experimental phantom and human studies.ResultsReconstructed images of the water and fat signal are shown for a phantom study, and in vivo studies of foot/ankle, pelvis, and CE‐MRA of the thighs. The method shown here compared favorably with the other two methods. Large field inhomogeneities on the order of 20 ppm were resolved, thereby avoiding the fat and water signal swaps present in images reconstructed with the other methods.ConclusionConstrained‐phase dual‐echo Dixon imaging solved with a regularized graph‐cuts‐guided optimization has been derived and demonstrated to successfully separate water and fat images in the presence of large magnetic field inhomogeneities. Magn Reson Med 78:2203–2215, 2017. © 2017 International Society for Magnetic Resonance in Medicine.
Dixon‐type and subtraction‐type contrast‐enhanced magnetic resonance angiography: A theoretical and experimental comparison of SNR and CNR
Stinson, Eric G. , Trzasko, Joshua D. , Weavers, Paul T., Riederer, Stephen J.

Magnetic Resonance in Medicine | July 17, 2014 | Volume: 74 | Issue: 1 | Pages: 81-92

10.1002/mrm.25374 Get It

PurposeThe purpose of this work is to compare the behavior of the signal‐to‐noise ratio (SNR) and contrast‐to‐noise ratio (CNR) in contrast‐enhanced MR angiography with background suppression performed by either a Dixon‐type or subtraction‐type method.Theory and MethodsTheoretical expressions for the SNR and CNR for both background suppression techniques were derived. The theoretical Dixon:subtraction SNR and CNR ratios were compared to empirical ratios measured from phantom and in vivo studies for Dixon techniques utilizing one, two, and three echoes. Specifically, the SNR and CNR ratios were compared as the concentration of contrast material in the blood changed.ResultsEmpirical measurements of the SNR and CNR ratios compared favorably with the ratios predicted by theory. As the contrast concentration was reduced, the SNR advantage of the Dixon techniques increased asymptotically. In the ideal case, the SNR improvement over subtraction contrast‐enhanced MR angiography was at least twofold for one‐ and two‐echo Dixon techniques and at least a factor of for the three‐echo Dixon technique.ConclusionExpressions showing a contrast concentration‐dependent SNR and CNR improvement of at least a factor of two when Dixon‐type contrast‐enhanced MR angiography is used in place of subtraction‐type contrast‐enhanced MR angiography were derived and validated with phantom and in vivo experiments. Magn Reson Med 74:81–92, 2015. © 2014 Wiley Periodicals, Inc.
Vascular masking for improved unfolding in 2D SENSE-accelerated 3D contrast-enhanced MR angiography
Stinson, Eric G. , Borisch, Eric A. , Johnson, Casey P. , Trzasko, Joshua D. , Young, Phillip M. , Riederer, Stephen J.

Journal of Magnetic Resonance Imaging | July 29, 2013 | Volume: 39 | Issue: 5 | Pages: 1161-1170

10.1002/jmri.24266 Get It