Weavers, Paul T.

Mayo Clinic

Mayo Clinic

Citations 15

Improving apparent diffusion coefficient accuracy on a compact 3T MRI scanner using gradient nonlinearity correction
Tao, Ashley , Shu, Yunhong , Trzasko, Joshua D. , Tao, Shengzhen , Reid, Robert D., Weavers, Paul T., Tao, Ashley T , Tao, Shengzhen , Tan, Ek T. , Huston, John , Bernstein, Matt A.

Journal of Magnetic Resonance Imaging | September 26, 2018 | Volume: 48 | Issue: 6 | Pages: 1498-1507

10.1002/jmri.26201 Get It

BackgroundGradient nonlinearity (GNL) leads to biased apparent diffusion coefficients (ADCs) in diffusion‐weighted imaging. A gradient nonlinearity correction (GNLC) method has been developed for whole body systems, but is yet to be tested for the new compact 3T (C3T) scanner, which exhibits more complex GNL due to its asymmetrical design.PurposeTo assess the improvement of ADC quantification with GNLC for the C3T scanner.Study TypePhantom measurements and retrospective analysis of patient data.Phantom/SubjectsA diffusion quality control phantom with vials containing 0–30% polyvinylpyrrolidone in water was used. For in vivo data, 12 patient exams were analyzed (median age, 33).Field Strength/SequenceImaging was performed on the C3T and two commercial 3T scanners. A clinical DWI (repetition time [TR] = 10,000 msec, echo time [TE] = minimum, b = 1000 s/mm2) sequence was used for phantom imaging and 10 patient cases and a clinical DTI (TR = 6000–10,000 msec, TE = minimum, b = 1000 s/mm2) sequence was used for two patient cases.AssessmentThe 0% vial was measured along three orthogonal axes, and at two different temperatures. The ADC for each concentration was compared between the C3T and two whole‐body scanners. Cerebrospinal fluid and white matter ADCs were quantified for each patient and compared to values in literature.Statistical TestsPaired t‐test and two‐way analysis of variance (ANOVA).ResultsFor all PVP concentrations, the corrected ADC was within 2.5% of the reference ADC. On average, the ADC of cerebrospinal fluid and white matter post‐GNLC were within 1% and 6%, respectively, of values reported in the literature and were significantly different from the uncorrected data (P < 0.05).Data ConclusionThis study demonstrated that GNL effects were more severe for the C3T due to the asymmetric gradient design, but our implementation of a GNLC compensated for these effects, resulting in ADC values that are in good agreement with values from the literature.Level of Evidence: 4Technical Efficacy: Stage 2J. Magn. Reson. Imaging 2018;48:1498–1507
Lightweight, compact, and high‐performance 3T MR system for imaging the brain and extremities
Foo, Thomas , Laskaris, E.T., Vermilyea, Mark, Xu, Minfeng , Thompson, Paul, Conte, Gene, Epps, Christopher Van, Immer, Christopher, Tan, Ek T. , Graziani, Dominic, Mathieu, Jean‐Baptise, Hardy, Christopher J., Schenck, John F., Fiveland, Eric, Stautner, Wolfgang , Ricci, Justin, Piel, Joseph E., Park, Keith, Hua, Yihe , Bai, Ye , Kagan, Alex, Stanley, David A. , Weavers, Paul T., Gray, Erin M. , Shu, Yunhong , Frick, Matthew A., Trzasko, Joshua D. , Foo, Thomas K F , Tan, Ek T , Gray, Erin, Trzasko, Joshua, Bernstein, Matt A , Thompson, Paul, Epps, Chris Van, Lee, Seung‐Kyun , Campeau, Norbert G. , Huston, John , Bernstein, Matt A.

Magnetic Resonance in Medicine | March 15, 2018 | Volume: 80 | Issue: 5 | Pages: 2232-2245

10.1002/mrm.27175 Get It

PurposeTo build and evaluate a small‐footprint, lightweight, high‐performance 3T MRI scanner for advanced brain imaging with image quality that is equal to or better than conventional whole‐body clinical 3T MRI scanners, while achieving substantial reductions in installation costs.MethodsA conduction‐cooled magnet was developed that uses less than 12 liters of liquid helium in a gas‐charged sealed system, and standard NbTi wire, and weighs approximately 2000 kg. A 42‐cm inner‐diameter gradient coil with asymmetric transverse axes was developed to provide patient access for head and extremity exams, while minimizing magnet‐gradient interactions that adversely affect image quality. The gradient coil was designed to achieve simultaneous operation of 80‐mT/m peak gradient amplitude at a slew rate of 700 T/m/s on each gradient axis using readily available 1‐MVA gradient drivers.ResultsIn a comparison of anatomical imaging in 16 patients using T2‐weighted 3D fluid‐attenuated inversion recovery (FLAIR) between the compact 3T and whole‐body 3T, image quality was assessed as equivalent to or better across several metrics. The ability to fully use a high slew rate of 700 T/m/s simultaneously with 80‐mT/m maximum gradient amplitude resulted in improvements in image quality across EPI, DWI, and anatomical imaging of the brain.ConclusionsThe compact 3T MRI system has been in continuous operation at the Mayo Clinic since March 2016. To date, over 200 patient studies have been completed, including 96 comparison studies with a clinical 3T whole‐body MRI. The increased gradient performance has reliably resulted in consistently improved image quality.
Technical Aspects of Contrast-enhanced MR Angiography: Current Status and New Applications
Riederer, Stephen J. , Stinson, Eric G. , Weavers, Paul T.

Magnetic Resonance in Medical Sciences | August 30, 2017 | Volume: 17 | Issue: 1 | Pages: 3-12

10.2463/mrms.rev.2017-0053 Get It

Magnetization‐prepared shells trajectory with automated gradient waveform design
Shu, Yunhong , Tao, Shengzhen , Trzasko, Joshua D. , Weavers, Paul T., Bernstein, Matt A. , Bernstein, Matt A , Huston, John

Magnetic Resonance in Medicine | August 22, 2017 | Volume: 79 | Issue: 4 | Pages: 2024-2035

10.1002/mrm.26863 Get It

PurposeTo develop a fully automated trajectory and gradient waveform design for the non‐Cartesian shells acquisition, and to develop a magnetization‐prepared (MP) shells acquisition to achieve an efficient three‐dimensional acquisition with improved gray‐to‐white brain matter contrast.MethodsAfter reviewing the shells k‐space trajectory, a novel, fully automated trajectory design is developed that allows for gradient waveforms to be automatically generated for specified acquisition parameters. Designs for two types of shells are introduced, including fully sampled and undersampled/accelerated shells. Using those designs, an MP‐Shells acquisition is developed by adjusting the acquisition order of shells interleaves to synchronize the center of k‐space sampling with the peak of desired gray‐to‐white matter contrast. The feasibility of the proposed design and MP‐Shells is demonstrated using simulation, phantom, and volunteer subject experiments, and the performance of MP‐Shells is compared with a clinical Cartesian magnetization‐prepared rapid gradient echo acquisition.ResultsInitial experiments show that MP‐Shells produces excellent image quality with higher data acquisition efficiency and improved gray‐to‐white matter contrast‐to‐noise ratio (by 36%) compared with the conventional Cartesian magnetization‐prepared rapid gradient echo acquisition.ConclusionWe demonstrated the feasibility of a three‐dimensional MP‐Shells acquisition and an automated trajectory design to achieve an efficient acquisition with improved gray‐to‐white matter contrast. Magn Reson Med 79:2024–2035, 2018. © 2017 International Society for Magnetic Resonance in Medicine.
The effect of concomitant fields in fast spin echo acquisition on asymmetric MRI gradient systems
Tao, Shengzhen , Weavers, Paul T., Trzasko, Joshua D. , Shu, Yunhong , Gray, Erin M. , Foo, Thomas , Bernstein, Matt A. , Bernstein, Matt A , Huston, John , Foo, Thomas K F

Magnetic Resonance in Medicine | June 23, 2017 | Volume: 79 | Issue: 3 | Pages: 1354-1364

10.1002/mrm.26789 Get It

PurposeTo investigate the effect of the asymmetric gradient concomitant fields (CF) with zeroth and first‐order spatial dependence on fast/turbo spin‐echo acquisitions, and to demonstrate the effectiveness of their real‐time compensation.MethodsAfter briefly reviewing the CF produced by asymmetric gradients, the effects of the additional zeroth and first‐order CFs on these systems are investigated using extended‐phase graph simulations. Phantom and in vivo experiments are performed to corroborate the simulation. Experiments are performed before and after the real‐time compensations using frequency tracking and gradient pre‐emphasis to demonstrate their effectiveness in correcting the additional CFs. The interaction between the CFs and prescan‐based correction to compensate for eddy currents is also investigated.ResultsIt is demonstrated that, unlike the second‐order CFs on conventional gradients, the additional zeroth/first‐order CFs on asymmetric gradients cause substantial signal loss and dark banding in fast spin‐echo acquisitions within a typical brain‐scan field of view. They can confound the prescan correction for eddy currents and degrade image quality. Performing real‐time compensation successfully eliminates the artifacts.ConclusionsWe demonstrate that the zeroth/first‐order CFs specific to asymmetric gradients can cause substantial artifacts, including signal loss and dark bands for brain imaging. These effects can be corrected using real‐time compensation. Magn Reson Med 79:1354–1364, 2018. © 2017 International Society for Magnetic Resonance in Medicine.
B0 concomitant field compensation for MRI systems employing asymmetric transverse gradient coils
Weavers, Paul T., Tao, Shengzhen , Trzasko, Joshua D. , Frigo, Louis M., Shu, Yunhong , Frick, Matthew A., Foo, Thomas , Bernstein, Matt A. , Bernstein, Matt A , Lee, Seung‐Kyun , Foo, Thomas K F

Magnetic Resonance in Medicine | June 22, 2017 | Volume: 79 | Issue: 3 | Pages: 1538-1544

10.1002/mrm.26790 Get It

PurposeImaging gradients result in the generation of concomitant fields, or Maxwell fields, which are of increasing importance at higher gradient amplitudes. These time‐varying fields cause additional phase accumulation, which must be compensated for to avoid image artifacts. In the case of gradient systems employing symmetric design, the concomitant fields are well described with second‐order spatial variation. Gradient systems employing asymmetric design additionally generate concomitant fields with global (zeroth‐order or B0) and linear (first‐order) spatial dependence.MethodsThis work demonstrates a general solution to eliminate the zeroth‐order concomitant field by applying the correct B0 frequency shift in real time to counteract the concomitant fields. Results are demonstrated for phase contrast, spiral, echo‐planar imaging (EPI), and fast spin‐echo imaging.ResultsA global phase offset is reduced in the phase‐contrast exam, and blurring is virtually eliminated in spiral images. The bulk image shift in the phase‐encode direction is compensated for in EPI, whereas signal loss, ghosting, and blurring are corrected in the fast‐spin echo images.ConclusionA user‐transparent method to compensate the zeroth‐order concomitant field term by center frequency shifting is proposed and implemented. This solution allows all the existing pulse sequences—both product and research—to be retained without any modifications. Magn Reson Med 79:1538–1544, 2018. © 2017 International Society for Magnetic Resonance in Medicine.
Gradient nonlinearity calibration and correction for a compact, asymmetric magnetic resonance imaging gradient system
Tao, Shengzhen , Trzasko, Joshua D. , Gunter, Jeffrey L. , Weavers, Paul T., Shu, Yunhong , Lee, Seung‐Kyun , Tan, Ek T. , Huston, John , Bernstein, Matt A. , Tan, Ek T

Physics in Medicine & Biology | December 29, 2016 | Volume: 62 | Issue: 2 | Pages: N18-N31

10.1088/1361-6560/aa524f Get It

Abstract Due to engineering limitations, the spatial encoding gradient fields in conventional magnetic resonance imaging cannot be perfectly linear and always contain higher-order, nonlinear components. If ignored during image reconstruction, gradient nonlinearity (GNL) manifests as image geometric distortion. Given an estimate of the GNL field, this distortion can be corrected to a degree proportional to the accuracy of the field estimate. The GNL of a gradient system is typically characterized using a spherical harmonic polynomial model with model coefficients obtained from electromagnetic simulation. Conventional whole-body gradient systems are symmetric in design; typically, only odd-order terms up to the 5th-order are required for GNL modeling. Recently, a high-performance, asymmetric gradient system was developed, which exhibits more complex GNL that requires higher-order terms including both odd- and even-orders for accurate modeling. This work characterizes the GNL of this system using an iterative calibration method and a fiducial phantom used in ADNI (Alzheimer’s Disease Neuroimaging Initiative). The phantom was scanned at different locations inside the 26 cm diameter-spherical-volume of this gradient, and the positions of fiducials in the phantom were estimated. An iterative calibration procedure was utilized to identify the model coefficients that minimize the mean-squared-error between the true fiducial positions and the positions estimated from images corrected using these coefficients. To examine the effect of higher-order and even-order terms, this calibration was performed using spherical harmonic polynomial of different orders up to the 10th-order including even- and odd-order terms, or odd-order only. The results showed that the model coefficients of this gradient can be successfully estimated. The residual root-mean-squared-error after correction using up to the 10th-order coefficients was reduced to 0.36 mm, yielding spatial accuracy comparable to conventional whole-body gradients. The even-order terms were necessary for accurate GNL modeling. In addition, the calibrated coefficients improved image geometric accuracy compared with the simulation-based coefficients.
Gradient pre-emphasis to counteract first-order concomitant fields on asymmetric MRI gradient systems
Tao, Shengzhen , Weavers, Paul T., Trzasko, Joshua D. , Shu, Yunhong , Frigo, Louis M., Bernstein, Matt A. , Bernstein, Matt A , Huston, John , Lee, Seung‐Kyun

Magnetic Resonance in Medicine | July 4, 2016 | Volume: 77 | Issue: 6 | Pages: 2250-2262

10.1002/mrm.26315 Get It

High slew‐rate head‐only gradient for improving distortion in echo planar imaging: Preliminary experience
Tan, Ek T. , Lee, Seung‐Kyun , Weavers, Paul T., Graziani, Dominic, Piel, Joseph E., Shu, Yunhong , Bernstein, Matt A. , Foo, Thomas , Huston, John , Bernstein, Matt A , Foo, Thomas K F , Tan, Ek T

Journal of Magnetic Resonance Imaging | February 27, 2016 | Volume: 44 | Issue: 3 | Pages: 653-664

10.1002/jmri.25210 Get It

PurposeTo investigate the effects on echo planar imaging (EPI) distortion of using high gradient slew rates (SR) of up to 700 T/m/s for in vivo human brain imaging, with a dedicated, head‐only gradient coil.Materials and MethodsSimulation studies were first performed to determine the expected echo spacing and distortion reduction in EPI. A head gradient of 42‐cm inner diameter and with asymmetric transverse coils was then installed in a whole‐body, conventional 3T magnetic resonance imaging (MRI) system. Human subject imaging was performed on five subjects to determine the effects of EPI on echo spacing and signal dropout at various gradient slew rates. The feasibility of whole‐brain imaging at 1.5 mm‐isotropic spatial resolution was demonstrated with gradient‐echo and spin‐echo diffusion‐weighted EPI.ResultsAs compared to a whole‐body gradient coil, the EPI echo spacing in the head‐only gradient coil was reduced by 48%. Simulation and in vivo results, respectively, showed up to 25–26% and 19% improvement in signal dropout. Whole‐brain imaging with EPI at 1.5 mm spatial resolution provided good whole‐brain coverage, spatial linearity, and low spatial distortion effects.ConclusionOur results of human brain imaging with EPI using the compact head gradient coil at slew rates higher than in conventional whole‐body MR systems demonstrate substantially improved image distortion, and point to a potential for benefits to non‐EPI pulse sequences. J. Magn. Reson. Imaging 2016;44:653–664.
Partial fourier and parallel MR image reconstruction with integrated gradient nonlinearity correction
Tao, Shengzhen , Trzasko, Joshua D. , Shu, Yunhong , Weavers, Paul T., Gray, Erin M. , Bernstein, Matt A. , Huston, John , Bernstein, Matt A

Magnetic Resonance in Medicine | July 17, 2015 | Volume: 75 | Issue: 6 | Pages: 2534-2544

10.1002/mrm.25842 Get It

PurposeTo describe how integrated gradient nonlinearity (GNL) correction can be used within noniterative partial Fourier (homodyne) and parallel (SENSE and GRAPPA) MR image reconstruction strategies, and demonstrate that performing GNL correction during, rather than after, these routines mitigates the image blurring and resolution loss caused by postreconstruction image domain based GNL correction.MethodsStarting from partial Fourier and parallel magnetic resonance imaging signal models that explicitly account for GNL, noniterative image reconstruction strategies for each accelerated acquisition technique are derived under the same core mathematical assumptions as their standard counterparts. A series of phantom and in vivo experiments on retrospectively undersampled data were performed to investigate the spatial resolution benefit of integrated GNL correction over conventional postreconstruction correction.ResultsPhantom and in vivo results demonstrate that the integrated GNL correction reduces the image blurring introduced by the conventional GNL correction, while still correcting GNL‐induced coarse‐scale geometrical distortion. Images generated from undersampled data using the proposed integrated GNL strategies offer superior depiction of fine image detail, for example, phantom resolution inserts and anatomical tissue boundaries.ConclusionNoniterative partial Fourier and parallel imaging reconstruction methods with integrated GNL correction reduce the resolution loss that occurs during conventional postreconstruction GNL correction while preserving the computational efficiency of standard reconstruction techniques. Magn Reson Med 75:2534–2544, 2016. © 2015 Wiley Periodicals, Inc.