https://orcid.org/0000-0001-7625-3141

Mayo Clinic

GE Global Research (United States)

Citations 9

Modeling and measurement of lead tip heating and resonant length for implanted, insulated wires
Speltz, Lydia J. Bardwell , Shu, Yunhong , Tarasek, Matthew , Trzasko, Joshua D. , Bernstein, Matt A. , Bardwell Speltz, Lydia J , Bernstein, Matt A , Lee, Seung‐Kyun , Foo, Thomas

Magnetic Resonance in Medicine | May 31, 2024 | Volume: 92 | Issue: 4 | Pages: 1714-1727

10.1002/mrm.30145 Get It

AbstractPurposeTo study implant lead tip heating because of the RF power deposition by developing mathematical models and comparing them with measurements acquired at 1.5 T and 3 T, especially to predict resonant length.Theory and MethodsA simple exponential model and an adapted transmission line model for the electric field transfer function were developed. A set of wavenumbers, including that calculated from insulated antenna theory (King wavenumber) and that of the embedding medium were considered. Experiments on insulated, capped wires of varying lengths were performed to determine maximum temperature rise under RF exposure. The results are compared with model predictions from analytical expressions derived under the assumption of a constant electric field, and with those numerically calculated from spatially varying, simulated electric fields from body coil transmission. Simple expressions for the resonant length bounded between one‐quarter and one‐half wavelength are developed based on the roots of transcendental equations.ResultsThe King wavenumber for both models more closely matched the experimental data with a maximum root mean square error of 9.81°C at 1.5 T and 5.71°C at 3 T compared to other wavenumbers with a maximum root mean square error of 27.52°C at 1.5 T and 22.01°C for 3 T. Resonant length was more accurately predicted compared to values solely based on the embedding medium.ConclusionAnalytical expressions were developed for implanted lead heating and resonant lengths under specific assumptions. The value of the wavenumber has a strong effect on the model predictions. Our work could be used to better manage implanted device lead tip heating.
Calibration of concomitant field offsets using phase contrast MRI for asymmetric gradient coils
Abad, Nastaren , Lee, Seung‐Kyun , Ajala, Afis , In, Myung‐Ho , Frigo, Louis M., Morris, H Douglas , Hua, Yihe , Ho, Vincent B. , Bernstein, Matt A. , Foo, Thomas , Bernstein, Matt A , Foo, Thomas K F , In, Myung-Ho , Bhushan, Chitresh

Magnetic Resonance in Medicine | September 21, 2022 | Volume: 89 | Issue: 1 | Pages: 262-275

10.1002/mrm.29452 Get It

PurposeAsymmetric gradient coils introduce zeroth‐ and first‐order concomitant field terms, in addition to higher‐order terms common to both asymmetric and symmetric gradients. Salient to compensation strategies is the accurate calibration of the concomitant field spatial offset parameters for asymmetric coils. A method that allows for one‐time calibration of the offset parameters is described.Theory and MethodsA modified phase contrast pulse sequence with single‐sided bipolar flow encoding is proposed to calibrate the offsets for asymmetric, transverse gradient coils. By fitting the measured phase offsets to different gradient amplitudes, the spatial offsets were calculated by fitting the phase variation. This was used for calibrating real‐time pre‐emphasis compensation of the zeroth‐ and first‐order concomitant fields.ResultsImage quality improvement with the proposed corrections was demonstrated in phantom and healthy volunteers with non‐Cartesian and Cartesian trajectory acquisitions. Concomitant field compensation using the calibrated offsets resulted in a residual phase error <3% at the highest gradient amplitude and demonstrated substantial reduction of image blur and slice position/selection artifacts.ConclusionsThe proposed implementation provides an accurate method for calibrating spatial offsets that can be used for real‐time concomitant field compensation of zeroth and first‐order terms, substantially reducing artifacts without retrospective correction or sequence specific waveform modifications.
Systematic Dimensional Analysis of the Scaling Relationship for Gradient and Shim Coil Design Parameters
Lee, Seung‐Kyun , Bernstein, Matt A. , Bernstein, Matt A

Magnetic Resonance in Medicine | June 6, 2022 | Volume: 88 | Issue: 4 | Pages: 1901-1911

10.1002/mrm.29316 Get It

PurposeTo demonstrate systematic, linear algebra–based, dimensional analysis to derive a scaling relationship among the design parameters of MRI gradient and harmonic shim coils.Theory and MethodsThe dimensions of five physical quantities relevant for gradient coil design (inductance, gradient amplitude, inner diameter [], current, and the permeability of free space) were decomposed into fundamental units, and their exponents were arranged into a dimensional matrix. The resulting set of homogenous equations was solved using standard linear algebraic methods. Inclusion of the number of turns as an additional unit yielded a 5 × 5 dimensional matrix with a unique, nontrivial solution. The analysis was extended to harmonic shim coils. The gradient coil scaling relationship was compared with data from 24 published gradient coil sets.ResultsOnly when the unit of turns was included did the linear algebra–based analysis uniquely produce the known scaling relationship that gradient inductance is proportional to gradient efficiency squared times . By applying the same methodology to anlth order shim coil, a novel result is obtained: Shim inductance is proportional to its efficiency squared times . The predicted power‐law relationship between inductance‐normalized gradient efficiency and the diameter accounted for > 92% of the efficiency variation of the surveyed gradient coils. A dimensionless parameter is proposed as an intrinsic figure‐of‐merit of gradient coil efficiency.ConclusionSystematic application of linear algebra–based dimensional analysis can provide new insight in gradient and shim coil design by revealing fundamental scaling relations and helping to guide the design and comparison of coils with different diameters.
Lightweight, compact, and high‐performance 3T MR system for imaging the brain and extremities
Foo, Thomas , Laskaris, E.T., Vermilyea, Mark, Xu, Minfeng , Thompson, Paul, Conte, Gene, Epps, Christopher Van, Immer, Christopher, Tan, Ek T. , Graziani, Dominic, Mathieu, Jean‐Baptise, Hardy, Christopher J., Schenck, John F., Fiveland, Eric, Stautner, Wolfgang , Ricci, Justin, Piel, Joseph E., Park, Keith, Hua, Yihe , Bai, Ye , Kagan, Alex, Stanley, David A. , Weavers, Paul T., Gray, Erin M. , Shu, Yunhong , Frick, Matthew A., Trzasko, Joshua D. , Foo, Thomas K F , Tan, Ek T , Gray, Erin, Trzasko, Joshua, Bernstein, Matt A , Thompson, Paul, Epps, Chris Van, Lee, Seung‐Kyun , Campeau, Norbert G. , Huston, John , Bernstein, Matt A.

Magnetic Resonance in Medicine | March 15, 2018 | Volume: 80 | Issue: 5 | Pages: 2232-2245

10.1002/mrm.27175 Get It

PurposeTo build and evaluate a small‐footprint, lightweight, high‐performance 3T MRI scanner for advanced brain imaging with image quality that is equal to or better than conventional whole‐body clinical 3T MRI scanners, while achieving substantial reductions in installation costs.MethodsA conduction‐cooled magnet was developed that uses less than 12 liters of liquid helium in a gas‐charged sealed system, and standard NbTi wire, and weighs approximately 2000 kg. A 42‐cm inner‐diameter gradient coil with asymmetric transverse axes was developed to provide patient access for head and extremity exams, while minimizing magnet‐gradient interactions that adversely affect image quality. The gradient coil was designed to achieve simultaneous operation of 80‐mT/m peak gradient amplitude at a slew rate of 700 T/m/s on each gradient axis using readily available 1‐MVA gradient drivers.ResultsIn a comparison of anatomical imaging in 16 patients using T2‐weighted 3D fluid‐attenuated inversion recovery (FLAIR) between the compact 3T and whole‐body 3T, image quality was assessed as equivalent to or better across several metrics. The ability to fully use a high slew rate of 700 T/m/s simultaneously with 80‐mT/m maximum gradient amplitude resulted in improvements in image quality across EPI, DWI, and anatomical imaging of the brain.ConclusionsThe compact 3T MRI system has been in continuous operation at the Mayo Clinic since March 2016. To date, over 200 patient studies have been completed, including 96 comparison studies with a clinical 3T whole‐body MRI. The increased gradient performance has reliably resulted in consistently improved image quality.
B0 concomitant field compensation for MRI systems employing asymmetric transverse gradient coils
Weavers, Paul T., Tao, Shengzhen , Trzasko, Joshua D. , Frigo, Louis M., Shu, Yunhong , Frick, Matthew A., Foo, Thomas , Bernstein, Matt A. , Bernstein, Matt A , Lee, Seung‐Kyun , Foo, Thomas K F

Magnetic Resonance in Medicine | June 22, 2017 | Volume: 79 | Issue: 3 | Pages: 1538-1544

10.1002/mrm.26790 Get It

PurposeImaging gradients result in the generation of concomitant fields, or Maxwell fields, which are of increasing importance at higher gradient amplitudes. These time‐varying fields cause additional phase accumulation, which must be compensated for to avoid image artifacts. In the case of gradient systems employing symmetric design, the concomitant fields are well described with second‐order spatial variation. Gradient systems employing asymmetric design additionally generate concomitant fields with global (zeroth‐order or B0) and linear (first‐order) spatial dependence.MethodsThis work demonstrates a general solution to eliminate the zeroth‐order concomitant field by applying the correct B0 frequency shift in real time to counteract the concomitant fields. Results are demonstrated for phase contrast, spiral, echo‐planar imaging (EPI), and fast spin‐echo imaging.ResultsA global phase offset is reduced in the phase‐contrast exam, and blurring is virtually eliminated in spiral images. The bulk image shift in the phase‐encode direction is compensated for in EPI, whereas signal loss, ghosting, and blurring are corrected in the fast‐spin echo images.ConclusionA user‐transparent method to compensate the zeroth‐order concomitant field term by center frequency shifting is proposed and implemented. This solution allows all the existing pulse sequences—both product and research—to be retained without any modifications. Magn Reson Med 79:1538–1544, 2018. © 2017 International Society for Magnetic Resonance in Medicine.
Gradient nonlinearity calibration and correction for a compact, asymmetric magnetic resonance imaging gradient system
Tao, Shengzhen , Trzasko, Joshua D. , Gunter, Jeffrey L. , Weavers, Paul T., Shu, Yunhong , Lee, Seung‐Kyun , Tan, Ek T. , Huston, John , Bernstein, Matt A. , Tan, Ek T

Physics in Medicine & Biology | December 29, 2016 | Volume: 62 | Issue: 2 | Pages: N18-N31

10.1088/1361-6560/aa524f Get It

Abstract Due to engineering limitations, the spatial encoding gradient fields in conventional magnetic resonance imaging cannot be perfectly linear and always contain higher-order, nonlinear components. If ignored during image reconstruction, gradient nonlinearity (GNL) manifests as image geometric distortion. Given an estimate of the GNL field, this distortion can be corrected to a degree proportional to the accuracy of the field estimate. The GNL of a gradient system is typically characterized using a spherical harmonic polynomial model with model coefficients obtained from electromagnetic simulation. Conventional whole-body gradient systems are symmetric in design; typically, only odd-order terms up to the 5th-order are required for GNL modeling. Recently, a high-performance, asymmetric gradient system was developed, which exhibits more complex GNL that requires higher-order terms including both odd- and even-orders for accurate modeling. This work characterizes the GNL of this system using an iterative calibration method and a fiducial phantom used in ADNI (Alzheimer’s Disease Neuroimaging Initiative). The phantom was scanned at different locations inside the 26 cm diameter-spherical-volume of this gradient, and the positions of fiducials in the phantom were estimated. An iterative calibration procedure was utilized to identify the model coefficients that minimize the mean-squared-error between the true fiducial positions and the positions estimated from images corrected using these coefficients. To examine the effect of higher-order and even-order terms, this calibration was performed using spherical harmonic polynomial of different orders up to the 10th-order including even- and odd-order terms, or odd-order only. The results showed that the model coefficients of this gradient can be successfully estimated. The residual root-mean-squared-error after correction using up to the 10th-order coefficients was reduced to 0.36 mm, yielding spatial accuracy comparable to conventional whole-body gradients. The even-order terms were necessary for accurate GNL modeling. In addition, the calibrated coefficients improved image geometric accuracy compared with the simulation-based coefficients.
Gradient pre-emphasis to counteract first-order concomitant fields on asymmetric MRI gradient systems
Tao, Shengzhen , Weavers, Paul T., Trzasko, Joshua D. , Shu, Yunhong , Frigo, Louis M., Bernstein, Matt A. , Bernstein, Matt A , Huston, John , Lee, Seung‐Kyun

Magnetic Resonance in Medicine | July 4, 2016 | Volume: 77 | Issue: 6 | Pages: 2250-2262

10.1002/mrm.26315 Get It

High slew‐rate head‐only gradient for improving distortion in echo planar imaging: Preliminary experience
Tan, Ek T. , Lee, Seung‐Kyun , Weavers, Paul T., Graziani, Dominic, Piel, Joseph E., Shu, Yunhong , Bernstein, Matt A. , Foo, Thomas , Huston, John , Bernstein, Matt A , Foo, Thomas K F , Tan, Ek T

Journal of Magnetic Resonance Imaging | February 27, 2016 | Volume: 44 | Issue: 3 | Pages: 653-664

10.1002/jmri.25210 Get It

PurposeTo investigate the effects on echo planar imaging (EPI) distortion of using high gradient slew rates (SR) of up to 700 T/m/s for in vivo human brain imaging, with a dedicated, head‐only gradient coil.Materials and MethodsSimulation studies were first performed to determine the expected echo spacing and distortion reduction in EPI. A head gradient of 42‐cm inner diameter and with asymmetric transverse coils was then installed in a whole‐body, conventional 3T magnetic resonance imaging (MRI) system. Human subject imaging was performed on five subjects to determine the effects of EPI on echo spacing and signal dropout at various gradient slew rates. The feasibility of whole‐brain imaging at 1.5 mm‐isotropic spatial resolution was demonstrated with gradient‐echo and spin‐echo diffusion‐weighted EPI.ResultsAs compared to a whole‐body gradient coil, the EPI echo spacing in the head‐only gradient coil was reduced by 48%. Simulation and in vivo results, respectively, showed up to 25–26% and 19% improvement in signal dropout. Whole‐brain imaging with EPI at 1.5 mm spatial resolution provided good whole‐brain coverage, spatial linearity, and low spatial distortion effects.ConclusionOur results of human brain imaging with EPI using the compact head gradient coil at slew rates higher than in conventional whole‐body MR systems demonstrate substantially improved image distortion, and point to a potential for benefits to non‐EPI pulse sequences. J. Magn. Reson. Imaging 2016;44:653–664.
Peripheral nerve stimulation characteristics of an asymmetric head‐only gradient coil compatible with a high‐channel‐count receiver array
Lee, Seung‐Kyun , Mathieu, Jean‐Baptiste, Graziani, Dominic, Piel, Joseph E., Budesheim, Eric, Fiveland, Eric, Hardy, Christopher J., Tan, Ek T. , Amm, Bruce, Foo, Thomas , Shu, Yunhong , Schenck, John F., Bernstein, Matt A. , Huston, John , Foo, Thomas K F , Tan, Ek T

Magnetic Resonance in Medicine | December 2, 2015 | Volume: 76 | Issue: 6 | Pages: 1939-1950

10.1002/mrm.26044 Get It

PurposeTo characterize peripheral nerve stimulation (PNS) of an asymmetric head‐only gradient coil that is compatible with a commercial high–channel‐count receive‐only array.MethodsTwo prototypes of an asymmetric head‐only gradient coil set with a 42‐cm inner diameter were constructed for brain imaging at 3T with maximum performance specifications of up to 85 mT/m and 708 T/m/s. Tests were performed in 24 volunteers to measure PNS thresholds with the transverse (x = left–right; y = anterior–posterior [A/P]) gradient coils of both prototypes. Fourteen of these 24 volunteers were also tested for the z‐gradient PNS in the second prototype and were scanned with high–slew‐rate echo planar imaging (EPI) immediately after the PNS tests.ResultsFor both prototypes, the y‐gradient PNS threshold was markedly higher than the x‐gradient threshold. The z‐gradient threshold was intermediate between those for the x‐ and y‐coils. Of the 24 volunteers, only two experienced y‐gradient PNS at 80 mT/m and 500 T/m/s. All volunteers underwent the EPI scan without PNS when the readout direction was set to A/P.ConclusionMeasured PNS characteristics of asymmetric head‐only gradient coil prototypes indicate that such coils, especially in the A/P direction, can be used for fast EPI readout in high‐performance neuroimaging scans with substantially reduced PNS concerns compared with conventional whole body gradient coils. Magn Reson Med 76:1939–1950, 2016. © 2015 International Society for Magnetic Resonance in Medicine