Back to Authors

In, Myung-Ho

0000-0001-8001-6237

Mayo Clinic

Department of Radiology, Mayo Clinic, Rochester, MN 55905, USA.

Citations 20

WSB1-Mediated PSMA Ubiquitination Promotes Enzalutamide-Induced Neuroendocrine-like Transition in Patient-Derived Prostate Cancer Spheroids
Jung, Dawa, Kendi, A. Tuba , Woodrum, David A. , In, Myung‐Ho , Bilgin, Gokce Belge , Johnson, Derek R. , Kim, Eun-Joo, Chung, Jin Ook , Park, Seon-Young , Curran, Geoffry L., Lowe, Val J. , Lee, Seung Baek , Kendi, A Tuba , Adamo, Daniel A. , In, Myung-Ho , Belge Bilgin, Gokce , Johnson, Derek R , Horn, Ian M, Lowe, Val J , Lee, Seung Baek , Thompson, Scott M. , Horn, Ian M. , Curran, Geoffry L.

International Journal of Molecular Sciences | August 3, 2026 | Volume: 27 | Issue: 15 | Pages: 6899

10.3390/ijms27156899 Get It

Long-established prostate cancer cell lines provide limited insight into how contemporary early prostate cancer evolves into drug-resistant and neuroendocrine-like refractory disease. Patient-derived three-dimensional (3D) ex vivo models may better preserve this transition. Here, we found that 8 of 10 magnetic resonance imaging-guided biopsy specimens from patients with early-stage prostate cancer generated sustained 3D tumor spheroid cultures. After 12 weeks of enzalutamide selection, only one patient-derived culture acquired a resistant phenotype with treatment-emergent neuroendocrine prostate cancer (t-NEPC)-like features, including increased chromogranin A (CgA) and synaptophysin (SYP); reduced androgen receptor (AR), prostate-specific antigen (PSA), and prostate-specific membrane antigen (PSMA); and conversion from compact spheroids into irregular resistant aggregates. During this transition, WD repeat and SOCS box-containing protein 1 (WSB1) increased, whereas PSMA progressively decreased. WSB1 silencing restored PSMA, AR, and PSA expression and reduced neuroendocrine-associated features. A similar WSB1 dependency was observed in enzalutamide-resistant LNCaP cells, the castration-resistant prostate cancer model 22Rv1, and the neuroendocrine/small-cell prostate cancer model NCI-H660. Mechanistically, WSB1 functioned as a SOCS box-dependent E3 ubiquitin ligase adaptor that promoted PSMA ubiquitination and degradation. SOCS box deletion or T380A mutation impaired this process, while Aurora kinase A (AURKA) inhibition reduced WSB1-dependent PSMA ubiquitination. WSB1 depletion, AURKA inhibition with alisertib, and combined AURKA inhibition with EZH2 suppression reduced resistant aggregate growth and increased apoptosis-associated markers in patient-derived enzalutamide-resistant neuroendocrine-like spheroids and related models. These findings nominate the AURKA–WSB1–PSMA axis as a therapeutic vulnerability in refractory prostate cancer.
White matter conduction in the human brain is mostly slow, with rare high velocity connections
Romero-Santiago, Samuel , Yáñez-Ramos, María Guadalupe , Bilderbeek, Jordan , Gregg, Nicholas M. , In, Myung‐Ho , Gray, Erin, Kang, Daehun , Shu, Yunhong , Worrell, Gregory A. , McIntyre, Cameron C. , Miller, Kai J. , Bilderbeek, Jordan A , Hermes, Dora , Yanez-Ramos, Maria Guadalupe , Worrell, Gregory A , Gregg, Nicholas M , Kang, Daehun , In, Myung-Ho , Gray, Erin M. , Hermes, Dora

No container title available | July 31, 2026 | Volume: No volume available | Issue: No issue available | Pages: No page available

10.64898/2026.07.28.741279 Get It

Abstract White matter bundles play a crucial role in cognitive functions by rapidly transmitting information between brain regions. Inter-areal conduction guides the integration of information and conduction velocity is a fundamental parameter in theories and models of brain function. However, distributions of conduction velocity remain difficult to characterize in vivo in humans. In this work, we integrated diffusion magnetic resonance imaging (dMRI) tractography with intracranial electrical stimulation during clinical stereo-electroencephalography (sEEG) monitoring in 17 subjects to measure conduction velocity within four major white matter bundles. Our findings reveal that human brain conduction is characterized by high variability both within and between bundles, reflecting a predominance of slow connections alongside rare high-speed connections. Because conduction velocity in myelinated fibers follows an approximately linear relationship with axon diameter, we derive underlying axon diameter distributions and show that these estimates are comparable to previous post-mortem studies. These findings demonstrate a heavily skewed distribution of human neural conduction velocities and show that structural heterogeneity shapes the timing and integration of information in large-scale networks.
First-in-Human Safety and Feasibility of Nodal and Pedal MR Lymphangiography with Gadopiclenol
Thompson, Scott M. , Collins, Jeremy D. , Bendel, Emily C. , Reisenauer, Christopher J., Jundt, Michael C., Yalҫin, Müge, Favazza, Christopher , Lu, Aiming , McDonald, Robert J. , Williamson, Eric E. , Stinson, Eric G. , In, MyungHo, Favazza, Christopher P , Messina, Steven A , Collins, Jeremy , Williamson, Eric , Thompson, Scott , Bendel, Emily , In, Myung-Ho , Jundt, Michael C., In, Myung‐Ho , Messina, Steven A.

Radiology: Cardiothoracic Imaging | July 2, 2026 | Volume: 8 | Issue: 4 | Pages: No page available

10.1148/ryct.260067 Get It

Dynamic gadopiclenol-enhanced nodal and pedal MR lymphangiography was safe, with no adverse events, and feasible for imaging peripheral and central conducting lymphatic anatomy.
Thermal and imaging effects of Feraheme in MR-guided focused ultrasound: a phantom study
In, Myung‐Ho , Long, Zaiyang , Hankiewicz, J , Russek, Stephen E. , Gu, Chunming , Gorny, Krzysztof R, Hangiandreou, Nicholas J., Dave, Jaydev K. , Tiegs‐Heiden, Christin A. , Hesley, Gina K. , Lu, Aiming , Gorny, Krzysztof R. , Hankiewicz, Janusz H , Nazarov, Alexey V , Russek, Stephen E , Gu, Chunming , Gorny, Krzysztof R , Dave, Jaydev K , Tiegs-Heiden, Christin A , Lu, Aiming , In, Myung-Ho

Physics in Medicine & Biology | June 18, 2026 | Volume: 71 | Issue: 13 | Pages: 135026

10.1088/1361-6560/ae7f67 Get It

Abstract Objective . The use of Feraheme (ferumoxytol) as a contrast agent in MR-guided focused ultrasound (MRgFUS) tumor ablations could enhance treatment safety and efficacy by improving vascular visualization through strong T1 and T2 shortening effects. However, Feraheme impact on MR thermometry and tissue heating is unclear. This study evaluates the feasibility of incorporating Feraheme into MRgFUS by assessing its impact on MR imaging contrast, MR thermometry, and thermal response in tissue-mimicking phantoms. Approach . Tissue-mimicking phantoms with 0 (baseline), 0.25, and 0.5 mM Feraheme concentrations were prepared using a validated recipe. Acoustic attenuation was measured with a commercial diagnostic ultrasound scanner. MR imaging at 1.5 T was performed to assess gradient-recalled-echo (GRE)-based thermometry signal-to-noise-ratio (SNR), relaxation rates, and relaxivities. MRgFUS system integrated with 1.5 T MRI was used to perform multiple sonications in the phantoms. Temperature elevations and focal heating areas were quantified from proton resonance frequency (PRF) shift thermometry. Experiments were repeated three times over the period of eight-weeks. Separately, temperature-dependent nuclear magnetic resonance (NMR) spectroscopy was performed at 3.0 T in saline-diluted Feraheme phantoms (0, 0.25, 0.5, and 1.0 mM) to assess the influence of Feraheme concentration on PRF coefficients used in MR thermometry. Main results . Phantoms showed nuclear relaxation times ( T 1: 1178.1 ± 77.8, T 2: 103.21 ± 2.45 ms) and attenuation coefficients (0.34–0.36 dB cm −1 MHz −1 ) within expected biological tissue ranges. Relaxivities demonstrated a strong linear dependence on Feraheme concentration ( r 1: 17.5 ± 0.2, r 2: 209.2 ± 2.6 s −1 mM −1 ). Relative to baseline (0 mM) phantom, the SNR of GRE-based thermometry increased by 12.6% at 0.25 mM and decreased by 27.1% at 0.5 mM. Sonications in Feraheme-containing phantoms resulted in statistically higher temperature elevations ( p < 0.001 ) although no statistically significant difference was observed between 0.25 and 0.5 mM. All NMR measurements demonstrated stable, linear PRF temperature dependence ( R 2 = 0.996–0.999), with PRF coefficients (between −0.0074 and −0.0082 ppm °C −1 ). The resulting thermometry bias was small and predictable (+0.67 and +1.73 per 20 °C at 3.0 T for 0.25 and 0.5 mM). Significance . These findings demonstrate that MR thermometry remains feasible at moderate Feraheme concentrations and support its potential use to enhance visualization of critical vasculature near targeted tissues during MRgFUS.
3D magnetization‐prepared rapid gradient echo with a RF saturation band on a compact 3T scanner
Speltz, Lydia J. Bardwell , In, Myung‐Ho , Trzasko, Joshua D. , Halverson, Maria, Gray, Erin M. , Shu, Yunhong , Bardwell Speltz, Lydia J , Gray, Erin, In, Myung-Ho , Kang, Daehun , Campeau, Norbert G. , Huston, John , Warner, David O. , Bernstein, Matt A.

Medical Physics | August 14, 2025 | Volume: 52 | Issue: 8 | Pages: No page available

10.1002/mp.18039 Get It

Abstract Background Flow‐related ghost artifact from a 3D Magnetization Prepared Rapid Gradient Echo (MPRAGE) sequence results from unsaturated magnetization of incoming arterial flow. This is especially common on MR scanners equipped with smaller radiofrequency (RF) transmit coils. A high‐performance compact 3T (C3T) scanner features a smaller RF‐transmit coil (inner diameter 37 cm, length 40 cm), leading to a rapid fall‐off of the B1 field below the neck. This configuration results in more intense flow‐related ghost artifacts, especially in younger patients. Purpose The C3T scanner's smaller RF‐transmit coil provides RF field coverage over the brain region, causing bright in‐flow arterial signals and flow‐related artifacts in the conventional 3D‐MPRAGE scans. The purpose of this study is to suppress these artifacts by adding a RF saturation band (RFSB) pulses to the 3D‐MPRAGE sequence. Methods The RFSB was added to the 3D‐MPRAGE sequence as a preparation pulse option. To test the effectiveness, 37 subjects were scanned on the C3T under an IRB‐approved protocol using 3D‐MPRAGE with and without RFSB. Ten of those subjects underwent repeated scans with and without RFSB to evaluate test‐retest reliability. A consensus evaluation by two neuroradiologists was performed on all data to compare signal to noise ratio, image contrast, presence of artifacts, and diagnostic confidence. Quantitative analysis included calculating test‐retest differences by image subtraction and evaluating the variance in flow‐artifact‐induced image intensity between the scans with and without RFSB. Additionally, one subject was scanned on a whole‐body 3T scanner using a transmit/receive (T/R) head coil to demonstrate the method's applicability across different MRI platforms as a proof of concept. Results The Wilcoxon signed‐rank test of the neuroradiologist evaluations showed a significant reduction in artifacts and an improvement in diagnostic confidence in the posterior fossa region with and without RFSB ( p < 0.0001). Test–retest analysis showed that adding RFSB significantly reduced image intensity variability in the cerebellum, even among subjects without visible flow artifacts. The normalized difference decreased from 8.71% to 6.41% ( p = 0.0059), suggesting improved image reliability in regions prone to flow‐related artifacts. Additionally, similar findings were observed in scans on a whole‐body 3T with a T/R head coil, demonstrating the broader applicability of this method. Conclusion Incorporating RFSB into 3D‐MPRAGE scans effectively reduces flow‐related ghost artifact on the C3T scanner, improving image quality and diagnostic confidence. These findings suggest that the proposed method could be widely implemented across MRI systems utilizing a smaller RF‐transmit coil.
Single pulse electrical stimulation in white matter modulates iEEG visual responses in human early visual cortex
Worrell, Gregory A. , In, Myung‐Ho , Gregg, Nicholas M. , Hermes, Dora , Kay, Kendrick , Huang, Harvey , Valencia, Gabriela Ojeda , Kapeller, Christoph , Huang, Harvey , Kay, Kendrick N , Ojeda Valencia, Gabriela , In, Myung-Ho , Kapeller, Christoph , Shu, Yunhong , Worrell, Gregory A , Miller, Kai J , Hermes, Dora , Gregg, Nicholas M , Shu, Yunhong , Miller, Kai J.

No container title available | May 10, 2025 | Volume: No volume available | Issue: No issue available | Pages: No page available

10.1101/2025.05.05.652264 Get It

Abstract Electrical stimulation is increasingly used to modulate brain networks for clinical purposes. The basic unit of neurostimulation, a single electrical pulse, can travel through white matter to influence connected neuronal populations. However, the mechanisms by which it influences connected populations is not well understood: stimulation may excite, inhibit, or add noise to neuronal population activity. In this study, we investigated how single pulses modulate the neuronal processing of images in a well-controlled visual paradigm. In two human subjects implanted with iEEG electrodes for clinical purposes, single pulses were delivered to electrodes in white matter tracts connected to measurement electrodes in visual cortex. Images appeared on-screen at 0, 100, or 200 ms after each pulse. Using finite impulse response modeling, we decomposed the broadband and evoked potential responses into separate components induced by electrical stimulation and by visual processing. Single pulses induced transient broadband increases followed by suppression, but they did not modulate the visual broadband responses (i.e., stimulation response was additive to visual response). In contrast, single pulses elicited prominent brain stimulation evoked potentials and they modulated the visual evoked potentials. Specifically, visual evoked potentials were larger when stimulation occurred closer to visual onset. This indicates that a single electrical pulse can increase the strength or synchrony of visual inputs. Overall, these findings suggest that the effects of electrical stimulation in the visual system are two-fold: stimulation induces additive effects on broadband power, possibly by adding noise, and it interacts with synchronous visual inputs to amplify them.
Thermometry mapping during CT-guided thermal ablations: proof of feasibility and internal validation using spectral CT
Zhang, Kuan , Ferrero, Andrea , In, Myung‐Ho , Favazza, Christopher , Favazza, Christopher P, In, Myung-Ho

Physics in Medicine & Biology | April 30, 2024 | Volume: 69 | Issue: 11 | Pages: 115022

10.1088/1361-6560/ad45a3 Get It

Abstract Objective . Conventional computed tomography (CT) imaging does not provide quantitative information on local thermal changes during percutaneous ablative therapy of cancerous and benign tumors, aside from few qualitative, visual cues. In this study, we have investigated changes in CT signal across a wide range of temperatures and two physical phases for two different tissue mimicking materials, each. Approach . A series of experiments were conducted using an anthropomorphic phantom filled with water-based gel and olive oil, respectively. Multiple, clinically used ablation devices were applied to locally cool or heat the phantom material and were arranged in a configuration that produced thermal changes in regions with inconsequential amounts of metal artifact. Eight fiber optic thermal sensors were positioned in the region absent of metal artifact and were used to record local temperatures throughout the experiments. A spectral CT scanner was used to periodically acquire and generate electron density weighted images. Average electron density weighted values in 1 mm 3 volumes of interest near the temperature sensors were computed and these data were then used to calculate thermal volumetric expansion coefficients for each material and phase. Main results . The experimentally determined expansion coefficients well-matched existing published values and variations with temperature—maximally differing by 5% of the known value. As a proof of concept, a CT-generated temperature map was produced during a heating time point of the water-based gel phantom, demonstrating the capability to map changes in electron density weighted signal to temperature. Significance . This study has demonstrated that spectral CT can be used to estimate local temperature changes for different materials and phases across temperature ranges produced by thermal ablations.
Locally Low-Rank Denoising of Multi-Echo Functional MRI Data With Application in Resting-State Analysis
Meyer, Nolan , Ahmed, Zaki , In, Myung‐Ho , Shu, Yunhong , Trzasko, Joshua D. , Meyer, Nolan K , In, Myung-Ho , Kang, Daehun , Huston, John , Bernstein, Matt A.

Topics in Magnetic Resonance Imaging | October 5, 2023 | Volume: 32 | Issue: 5 | Pages: 37-49

10.1097/rmr.0000000000000307 Get It

Abstract: Objectives: Locally low-rank (LLR) denoising of functional magnetic resonance imaging (fMRI) time series image data is extended to multi-echo (ME) data. The proposed method extends the capabilities of non-physiologic noise suppression beyond single-echo applications with a dedicated ME algorithm. Materials and Methods: Following an institutional review board (IRB) approved protocol, resting-state fMRI data were acquired in 7 healthy subjects. A compact 3T scanner enabled whole-brain acquisition of multiband ME fMRI data at high spatial resolution (1.4 × 1.4 × 2.8 mm3) with a 1810 ms repetition time (TR). Image data were denoised with ME-LLR preceding functional processing. The results of connectivity maps generated from denoised data were compared with maps generated with equivalent processing of non-denoised images. To assess ME-LLR as a method to reduce scan time, comparisons were made between maps computed from image data with full and retrospectively truncated durations. Assessments were completed with seed-based connectivity analyses using echo-combined image data. In a feasibility assessment, nondenoised and denoised full-duration echo-combined data were equivalently processed with independent component analysis (ICA) and compared. Results: ME-LLR denoising yielded strengthened resting-state network connectivity maps after nuisance regression and seed-based connectivity analysis. In assessing ME-LLR as a scan reduction mechanism, maps generated from denoised data at half scan time showed comparable quality with maps generated from full-duration, non-denoised data, at both single subject and group levels. ME-LLR substantially increased temporal signal-to-noise ratio (tSNR) for image data respective to each individual echo and for image data after nuisance regression. Among echo-specific image volumes, increases in tSNR yielded by ME-LLR were most pronounced for image data with the longest echo time and thereby lowest SNR. ICA showed resting-state networks consistently identified between non-denoised and denoised data, with clearer demarcation of networks for ME-LLR. Conclusions: ME-LLR is demonstrated to suppress non-physiologic noise, enhance functional connectivity map quality, and could potentially facilitate scan time reduction in ME-fMRI.
Improved Resting-State Functional MRI Using Multi-Echo Echo-Planar Imaging on a Compact 3T MRI Scanner with High-Performance Gradients
Kang, Daehun , In, Myung‐Ho , Halverson, Maria, Meyer, Nolan , Ahmed, Zaki , Gray, Erin M. , Fernandez, Brice , Black, David F. , Welker, Kirk M. , Trzasko, Joshua D. , Huston, John , Shu, Yunhong , Huston, John , Halverson, Maria A, Meyer, Nolan K , Ahmed, Zaki , Fernandez, Brice , Shu, Yunhong , Kang, Daehun , In, Myung-Ho , Jo, Hang Joon , Madhavan, Radhika , Foo, Thomas , Bernstein, Matt A.

Sensors | April 28, 2023 | Volume: 23 | Issue: 9 | Pages: 4329

10.3390/s23094329 Get It

In blood-oxygen-level-dependent (BOLD)-based resting-state functional (RS-fMRI) studies, usage of multi-echo echo-planar-imaging (ME-EPI) is limited due to unacceptable late echo times when high spatial resolution is used. Equipped with high-performance gradients, the compact 3T MRI system (C3T) enables a three-echo whole-brain ME-EPI protocol with smaller than 2.5 mm isotropic voxel and shorter than 1 s repetition time, as required in landmark fMRI studies. The performance of the ME-EPI was comprehensively evaluated with signal variance reduction and region-of-interest-, seed- and independent-component-analysis-based functional connectivity analyses and compared with a counterpart of single-echo EPI with the shortest TR possible. Through the multi-echo combination, the thermal noise level is reduced. Functional connectivity, as well as signal intensity, are recovered in the medial orbital sulcus and anterior transverse collateral sulcus in ME-EPI. It is demonstrated that ME-EPI provides superior sensitivity and accuracy for detecting functional connectivity and/or brain networks in comparison with single-echo EPI. In conclusion, the high-performance gradient enabled high-spatial-temporal resolution ME-EPI would be the method of choice for RS-fMRI study on the C3T.
Minimizing susceptibility-induced BOLD sensitivity loss in multi-band accelerated fMRI using point spread function mapping and gradient reversal
In, Myung‐Ho , Yarach, Uten , Meyer, Nolan , Trzasko, Joshua D. , Shu, Yunhong , Meyer, Nolan K , Shu, Yunhong , In, Myung-Ho , Kang, Daehun , Jo, Hang Joon , Huston, John , Bernstein, Matt A.

Physics in Medicine & Biology | December 22, 2022 | Volume: 68 | Issue: 2 | Pages: 025012

10.1088/1361-6560/acae14 Get It

Abstract Objective . Interleaved reverse-gradient fMRI (RG-fMRI) with a point-spread-function (PSF) mapping-based distortion correction scheme has the potential to minimize signal loss in echo-planar-imaging (EPI). In this work, the RG-fMRI is further improved by imaging protocol optimization and application of reverse Fourier acquisition. Approach . Multi-band imaging was adapted for RG-fMRI to improve the temporal and spatial resolution. To better understand signal dropouts in forward and reverse EPIs, a simple theoretical relationship between echo shift and geometric distortion was derived and validated by the reliable measurements using PSF mapping method. After examining practical imaging protocols for RG-fMRI in three subjects on both a conventional whole-body and a high-performance compact 3 T, the results were compared and the feasibility to further improve the RG-fMRI scheme were explored. High-resolution breath-holding RG-fMRI was conducted with nine subjects on the compact 3 T and the fMRI reliability improvement in high susceptibility brain regions was demonstrated. Finally, reverse Fourier acquisition was applied to RG-fMRI, and its benefit was assessed by a simulation study based on the breath-holding RG-fMRI data. Main results . The temporal and spatial resolution of the multi-band RG-fMRI became feasible for whole-brain fMRI. Echo shift measurements from PSF mapping well estimated signal dropout effects in the EPI pair and were useful to further improve the RG-fMRI scheme. Breath-holding RG-fMRI demonstrated improved fMRI reliability in high susceptibility brain regions. Reverse partial Fourier acquisition omitting the late echoes could further improve the temporal or spatial resolution for RG-fMRI without noticeable signal degradation and spatial resolution loss. Significance . With the improved imaging scheme, RG-fMRI could reliably investigate the functional mechanisms of the human brain in the temporal and frontal areas suffering from susceptibility-induced functional sensitivity loss.