Back to Authors

Russek, Stephen E

0000-0002-8788-2442

Mayo Clinic

National Institute of Standards and Technology (NIST), Boulder, CO 80305, United States of America.

Citations 3

Thermal and imaging effects of Feraheme in MR-guided focused ultrasound: a phantom study
In, Myung‐Ho , Long, Zaiyang , Hankiewicz, J , Russek, Stephen E. , Gu, Chunming , Gorny, Krzysztof R, Hangiandreou, Nicholas J., Dave, Jaydev K. , Tiegs‐Heiden, Christin A. , Hesley, Gina K. , Lu, Aiming , Gorny, Krzysztof R. , Hankiewicz, Janusz H , Nazarov, Alexey V , Russek, Stephen E , Gu, Chunming , Gorny, Krzysztof R , Dave, Jaydev K , Tiegs-Heiden, Christin A , Lu, Aiming , In, Myung-Ho

Physics in Medicine & Biology | June 18, 2026 | Volume: 71 | Issue: 13 | Pages: 135026

10.1088/1361-6560/ae7f67 Get It

Abstract Objective . The use of Feraheme (ferumoxytol) as a contrast agent in MR-guided focused ultrasound (MRgFUS) tumor ablations could enhance treatment safety and efficacy by improving vascular visualization through strong T1 and T2 shortening effects. However, Feraheme impact on MR thermometry and tissue heating is unclear. This study evaluates the feasibility of incorporating Feraheme into MRgFUS by assessing its impact on MR imaging contrast, MR thermometry, and thermal response in tissue-mimicking phantoms. Approach . Tissue-mimicking phantoms with 0 (baseline), 0.25, and 0.5 mM Feraheme concentrations were prepared using a validated recipe. Acoustic attenuation was measured with a commercial diagnostic ultrasound scanner. MR imaging at 1.5 T was performed to assess gradient-recalled-echo (GRE)-based thermometry signal-to-noise-ratio (SNR), relaxation rates, and relaxivities. MRgFUS system integrated with 1.5 T MRI was used to perform multiple sonications in the phantoms. Temperature elevations and focal heating areas were quantified from proton resonance frequency (PRF) shift thermometry. Experiments were repeated three times over the period of eight-weeks. Separately, temperature-dependent nuclear magnetic resonance (NMR) spectroscopy was performed at 3.0 T in saline-diluted Feraheme phantoms (0, 0.25, 0.5, and 1.0 mM) to assess the influence of Feraheme concentration on PRF coefficients used in MR thermometry. Main results . Phantoms showed nuclear relaxation times ( T 1: 1178.1 ± 77.8, T 2: 103.21 ± 2.45 ms) and attenuation coefficients (0.34–0.36 dB cm −1 MHz −1 ) within expected biological tissue ranges. Relaxivities demonstrated a strong linear dependence on Feraheme concentration ( r 1: 17.5 ± 0.2, r 2: 209.2 ± 2.6 s −1 mM −1 ). Relative to baseline (0 mM) phantom, the SNR of GRE-based thermometry increased by 12.6% at 0.25 mM and decreased by 27.1% at 0.5 mM. Sonications in Feraheme-containing phantoms resulted in statistically higher temperature elevations ( p < 0.001 ) although no statistically significant difference was observed between 0.25 and 0.5 mM. All NMR measurements demonstrated stable, linear PRF temperature dependence ( R 2 = 0.996–0.999), with PRF coefficients (between −0.0074 and −0.0082 ppm °C −1 ). The resulting thermometry bias was small and predictable (+0.67 and +1.73 per 20 °C at 3.0 T for 0.25 and 0.5 mM). Significance . These findings demonstrate that MR thermometry remains feasible at moderate Feraheme concentrations and support its potential use to enhance visualization of critical vasculature near targeted tissues during MRgFUS.
Aqueous Dispersion of Manganese–Zinc Ferrite Nanoparticles Protected by PEG as a T2 MRI Temperature Contrast Agent
Lachowicz, Dorota , Kmita, Angelika , Gajewska, Marta , Trynkiewicz, Elżbieta, Przybylski, Marek , Russek, Stephen E, Stupic, Karl F, Woodrum, David A, Gorny, Krzysztof R, Celinski, Zbigniew J, Hankiewicz, Janusz H , Russek, Stephen E. , Hankiewicz, J , Russek, Stephen E , Lachowicz, Dorota, Kmita, Angelika, Gajewska, Marta, Trynkiewicz, Elżbieta, Przybylski, Marek, Russek, Stephen E, Stupic, Karl F, Woodrum, David A, Gorny, Krzysztof R, Celinski, Zbigniew J, Hankiewicz, Janusz H

International Journal of Molecular Sciences | November 17, 2023 | Volume: 24 | Issue: 22 | Pages: 16458

10.3390/ijms242216458 Get It

Mixed manganese–zinc ferrite nanoparticles coated with PEG were studied for their potential usefulness in MRI thermometry as temperature-sensitive contrast agents. Particles in the form of an 8.5 nm core coated with a 3.5 nm layer of PEG were fabricated using a newly developed, one-step method. The composition of Mn0.48Zn0.46Fe2.06O4 was found to have a strong thermal dependence of magnetization in the temperature range between 5 and 50 °C. Nanoparticles suspended in an agar gel mimicking animal tissue and showing non-significant impact on cell viability in the biological test were studied with NMR and MRI over the same temperature range. For the concentration of 0.017 mg/mL of Fe, the spin–spin relaxation time T2 increased from 3.1 to 8.3 ms, while longitudinal relaxation time T1 shows a moderate decrease from 149.0 to 125.1 ms. A temperature map of the phantom exposed to the radial temperature gradient obtained by heating it with an 808 nm laser was calculated from T2 weighted spin-echo differential MR images. Analysis of temperature maps yields thermal/spatial resolution of 3.2 °C at the distance of 2.9 mm. The experimental relaxation rate R2 data of water protons were compared with those obtained from calculations using a theoretical model incorporating the motion averaging regime.
A standard system phantom for magnetic resonance imaging
Stupic, Karl F. , Ainslie, Maureen, Boss, Michael A. , Charles, Cecil, Dienstfrey, Andrew , Evelhoch, Jeffrey L., Finn, Paul, Gimbutas, Zydrunas , Gunter, Jeffrey L. , Hill, David , Karaulanov, Todor , Liu, Guoying , Martin, Michele N. , Prasad, Pottumarthi V. , Rentz, Nikki S., Yuan, Chun , Keenan, Kathryn E , Yuan, Chun , Russek, Stephen E , Boss, Michael A , Jack, Clifford R. , Jackson, Edward F. , Keenan, Kathryn E. , Russek, Stephen E.

Magnetic Resonance in Medicine | April 13, 2021 | Volume: 86 | Issue: 3 | Pages: 1194-1211

10.1002/mrm.28779 Get It

Purpose A standard MRI system phantom has been designed and fabricated to assess scanner performance, stability, comparability and assess the accuracy of quantitative relaxation time imaging. The phantom is unique in having traceability to the International System of Units, a high level of precision, and monitoring by a national metrology institute. Here, we describe the phantom design, construction, imaging protocols, and measurement of geometric distortion, resolution, slice profile, signal‐to‐noise ratio (SNR), proton‐spin relaxation times, image uniformity and proton density. Methods The system phantom, designed by the International Society of Magnetic Resonance in Medicine ad hoc committee on Standards for Quantitative MR, is a 200 mm spherical structure that contains a 57‐element fiducial array; two relaxation time arrays; a proton density/SNR array; resolution and slice‐profile insets. Standard imaging protocols are presented, which provide rapid assessment of geometric distortion, image uniformity, T 1 and T 2 mapping, image resolution, slice profile, and SNR. Results Fiducial array analysis gives assessment of intrinsic geometric distortions, which can vary considerably between scanners and correction techniques. This analysis also measures scanner/coil image uniformity, spatial calibration accuracy, and local volume distortion. An advanced resolution analysis gives both scanner and protocol contributions. SNR analysis gives both temporal and spatial contributions. Conclusions A standard system phantom is useful for characterization of scanner performance, monitoring a scanner over time, and to compare different scanners. This type of calibration structure is useful for quality assurance, benchmarking quantitative MRI protocols, and to transition MRI from a qualitative imaging technique to a precise metrology with documented accuracy and uncertainty.