Findings of the AAPM Ad Hoc committee on magnetic resonance imaging in radiation therapy: Unmet needs, opportunities, and recommendations
McGee, Kiaran P. , Tyagi, Neelam , Bayouth, John E. , Fallone, B. G. , Glide‐Hurst, Carri , Goerner, F, Green, Olga L., Kim, Taeho , Paulson, E.S. , Yanasak, N. E. , Goodwin, James, Jordan, David W. , Hugo, Geoffrey D., Balter, James M. , Kanal, Kalpana M. , Hazle, John D. , Pelc, Norbert J. , Cao, Minsong , Jackson, Edward F. , Dieterich, Sonja , Bernstein, Matt A.

Medical Physics | July 7, 2021 | Volume: 48 | Issue: 8 | Pages: 4523-4531

10.1002/mp.14996 Get It

The past decade has seen the increasing integration of magnetic resonance (MR) imaging into radiation therapy (RT). This growth can be contributed to multiple factors, including hardware and software advances that have allowed the acquisition of high‐resolution volumetric data of RT patients in their treatment position (also known as MR simulation) and the development of methods to image and quantify tissue function and response to therapy. More recently, the advent of MR‐guided radiation therapy (MRgRT) ‐ achieved through the integration of MR imaging systems and linear accelerators ‐ has further accelerated this trend. As MR imaging in RT techniques and technologies, such as MRgRT, gain regulatory approval worldwide, these systems will begin to propagate beyond tertiary care academic medical centers and into more community‐based health systems and hospitals, creating new opportunities to provide advanced treatment options to a broader patient population. Accompanying these opportunities are unique challenges related to their adaptation, adoption, and use including modification of hardware and software to meet the unique and distinct demands of MR imaging in RT, the need for standardization of imaging techniques and protocols, education of the broader RT community (particularly in regards to MR safety) as well as the need to continue and support research, and development in this space. In response to this, an ad hoc committee of the American Association of Physicists in Medicine (AAPM) was formed to identify the unmet needs, roadblocks, and opportunities within this space. The purpose of this document is to report on the major findings and recommendations identified. Importantly, the provided recommendations represent the consensus opinions of the committee’s membership, which were submitted in the committee's report to the AAPM Board of Directors. In addition, AAPM ad hoc committee reports differ from AAPM task group reports in that ad hoc committee reports are neither reviewed nor ultimately approved by the committee’s parent groups, including at the council and executive committee level. Thus, the recommendations given in this summary should not be construed as being endorsed by or official recommendations from the AAPM.
A standard system phantom for magnetic resonance imaging
Stupic, Karl F. , Ainslie, Maureen, Boss, Michael A. , Charles, Cecil, Dienstfrey, Andrew , Evelhoch, Jeffrey L., Finn, Paul, Gimbutas, Zydrunas , Gunter, Jeffrey L. , Hill, David , Karaulanov, Todor , Liu, Guoying , Martin, Michele N. , Prasad, Pottumarthi V. , Rentz, Nikki S., Yuan, Chun , Keenan, Kathryn E , Yuan, Chun , Russek, Stephen E , Boss, Michael A , Jack, Clifford R. , Jackson, Edward F. , Keenan, Kathryn E. , Russek, Stephen E.

Magnetic Resonance in Medicine | April 13, 2021 | Volume: 86 | Issue: 3 | Pages: 1194-1211

10.1002/mrm.28779 Get It

Purpose A standard MRI system phantom has been designed and fabricated to assess scanner performance, stability, comparability and assess the accuracy of quantitative relaxation time imaging. The phantom is unique in having traceability to the International System of Units, a high level of precision, and monitoring by a national metrology institute. Here, we describe the phantom design, construction, imaging protocols, and measurement of geometric distortion, resolution, slice profile, signal‐to‐noise ratio (SNR), proton‐spin relaxation times, image uniformity and proton density. Methods The system phantom, designed by the International Society of Magnetic Resonance in Medicine ad hoc committee on Standards for Quantitative MR, is a 200 mm spherical structure that contains a 57‐element fiducial array; two relaxation time arrays; a proton density/SNR array; resolution and slice‐profile insets. Standard imaging protocols are presented, which provide rapid assessment of geometric distortion, image uniformity, T 1 and T 2 mapping, image resolution, slice profile, and SNR. Results Fiducial array analysis gives assessment of intrinsic geometric distortions, which can vary considerably between scanners and correction techniques. This analysis also measures scanner/coil image uniformity, spatial calibration accuracy, and local volume distortion. An advanced resolution analysis gives both scanner and protocol contributions. SNR analysis gives both temporal and spatial contributions. Conclusions A standard system phantom is useful for characterization of scanner performance, monitoring a scanner over time, and to compare different scanners. This type of calibration structure is useful for quality assurance, benchmarking quantitative MRI protocols, and to transition MRI from a qualitative imaging technique to a precise metrology with documented accuracy and uncertainty.
ACR guidance document on MR safe practices: Updates and critical information 2019
Greenberg, Todd D., Hoff, Michael N. , Gilk, Tobias , Och, Joseph, Rampulla, Tina L., Rogg, Jeffrey M. , Shellock, Frank G. , Watson, Robert E. , Weinreb, Jeffrey C. , Hernandez, Dina , Jackson, Edward F. , Kanal, Emanuel , McKinney, Alexander M. , Pedrosa, Iván , Reeder, Scott B.

Journal of Magnetic Resonance Imaging | July 29, 2019 | Volume: 51 | Issue: 2 | Pages: 331-338

10.1002/jmri.26880 Get It

The need for a guidance document on MR safe practices arose from a growing awareness of the MR environment's potential risks and adverse event reports involving patients, equipment, and personnel. Initially published in 2002, the American College of Radiology White Paper on MR Safety established de facto industry standards for safe and responsible practices in clinical and research MR environments. The most recent version addresses new sources of risk of adverse events, increases awareness of dynamic MR environments, and recommends that those responsible for MR medical director safety undergo annual MR safety training. With regular updates to these guidelines, the latest MR safety concerns can be accounted for to ensure a safer MR environment where dangers are minimized.Level of Evidence: 1Technical Efficacy Stage: 5J. Magn. Reson. Imaging 2020;51:331–338.
Quantitative magnetic resonance imaging phantoms: A review and the need for a system phantom
Keenan, Kathryn E. , Ainslie, Maureen, Barker, Alex J. , Boss, Michael A. , Cecil, Kim M. , Charles, Cecil, Chenevert, Thomas L. , Clarke, L., Evelhoch, Jeffrey L., Finn, Paul, Gembris, Daniel, Gunter, Jeffrey L. , Hill, David , Jack, Clifford R. , Liu, Guoying , Sharma, Samir D. , Steckner, Michael , Stupic, Karl F. , Trzasko, Joshua D. , Yuan, Chun , Zheng, Jie , Jack, Clifford R , Barker, Alex J , Keenan, Kathryn E , Boss, Michael A , Jackson, Edward F. , Russek, Stephen E.

Magnetic Resonance in Medicine | October 30, 2017 | Volume: 79 | Issue: 1 | Pages: 48-61

10.1002/mrm.26982 Get It

The MRI community is using quantitative mapping techniques to complement qualitative imaging. For quantitative imaging to reach its full potential, it is necessary to analyze measurements across systems and longitudinally. Clinical use of quantitative imaging can be facilitated through adoption and use of a standard system phantom, a calibration/standard reference object, to assess the performance of an MRI machine. The International Society of Magnetic Resonance in Medicine AdHoc Committee on Standards for Quantitative Magnetic Resonance was established in February 2007 to facilitate the expansion of MRI as a mainstream modality for multi‐institutional measurements, including, among other things, multicenter trials. The goal of the Standards for Quantitative Magnetic Resonance committee was to provide a framework to ensure that quantitative measures derived from MR data are comparable over time, between subjects, between sites, and between vendors. This paper, written by members of the Standards for Quantitative Magnetic Resonance committee, reviews standardization attempts and then details the need, requirements, and implementation plan for a standard system phantom for quantitative MRI. In addition, application‐specific phantoms and implementation of quantitative MRI are reviewed. Magn Reson Med 79:48–61, 2018. © 2017 International Society for Magnetic Resonance in Medicine.