ABSTRACTBACKGROUND AND PURPOSEComprehensive imaging characterization of the morphology and luminal patency of cerebral aneurysms are cornerstones of their successful treatment and subsequent appropriate management. Giant cerebral aneurysms (GCAs), a distinct subgroup of aneurysms, are defined by large size (≥ 25 mm in greatest diameter), complex blood flow dynamics, and a high risk of rupture. The purpose of this study is to explore compare multiple imaging modalities in the assessment of GCAs.METHODSThis study retrospectively evaluated CT angiography (CTA), 3D time‐of‐flight (TOF) MR angiography (MRA), contrast‐enhanced MRA (CEMRA), and digital subtraction angiography (DSA) in characterizing GCAs in 21 patients.RESULTSAneurysm size ranged from 26 to 58 mm (mean 31.3 ± 12.2) and 18/21 (85.7%) had intraluminal thrombus. No significant difference was found between the aneurysmal sizes of any two modalities regarding comparisons of CTA, 3D TOFMRA, and CEMRA. However, there were significant differences in the aneurysmal patency visibility grade between CTA versus TOFMRA and CTA versus CEMRA. Moreover, the patent luminal size measured on CTA was significantly larger than DSA.CONCLUSIONSCTA, 3D TOFMRA, and CEMRA are equivalent in the delineation of size of GCAs. Nevertheless, 3D TOFMRA and CEMRA seem to be inferior to CTA in demonstrating luminal size/patency, likely because of the signal loss resulting from the presence of intraluminal thrombus and flow turbulence. Moreover, CTA is superior to DSA in determining lumen patency in GCAs, probably due to CTA's multipass‐related luminal enhancement while DSA general fills the lesion via the first pass of enhancement or soon thereafter. In addition, CTA may also better demonstrate intraluminal thrombus, adjacent anatomical structures, and calcified rims.
ACR guidance document on MR safe practices: Updates and critical information 2019
The need for a guidance document on MR safe practices arose from a growing awareness of the MR environment's potential risks and adverse event reports involving patients, equipment, and personnel. Initially published in 2002, the American College of Radiology White Paper on MR Safety established de facto industry standards for safe and responsible practices in clinical and research MR environments. The most recent version addresses new sources of risk of adverse events, increases awareness of dynamic MR environments, and recommends that those responsible for MR medical director safety undergo annual MR safety training. With regular updates to these guidelines, the latest MR safety concerns can be accounted for to ensure a safer MR environment where dangers are minimized.Level of Evidence: 1Technical Efficacy Stage: 5J. Magn. Reson. Imaging 2020;51:331–338.
Optic Neuropathy Secondary to Spontaneous Intracranial Hypotension (SIH) as Related to Experimental Primate Model