Back to Authors

Reeder, Scott B.

0000-0003-4728-8171

Mayo Clinic

University of Wisconsin–Madison

Citations 9

Cross‐Vendor Validation of Proton Density Fat Fraction and T 1 Mapping Using a Combined Proton Density Fat Fraction—
Starekova, Jitka , Weingärtner, Sebastian , Rutkowski, David , Fullerton, Garrett , Bae, Won C. , Do, Hung P. , Madhuranthakam, Ananth J. , Lin, S. , Serai, Suraj D., Brittain, Jean H. , Hernando, D, Rutkowski, David R , Fullerton, Garrett C , Lin, Sheng Qing , Serai, Suraj D , Yokoo, Takeshi , Reeder, Scott B. , Brittain, Jean H , Hernando, Diego , Do, Hung Phi , Malis, Vadim , Serai, Suraj D. , Yokoo, Takeshi

Journal of Magnetic Resonance Imaging | May 20, 2026 | Volume: 64 | Issue: 2 | Pages: 482-492

10.1002/jmri.70344 Get It

ABSTRACT Background In chronic liver disease, fat and fibroinflammatory changes often coexist. However, their biomarkers, proton density fat fraction (PDFF) and T 1 , are typically assessed separately. Their reproducibility under mutual confounding remains unclear. Purpose To assess multicenter, multi‐vendor reproducibility of confounder‐corrected chemical shift‐encoded (CSE)‐MRI‐based PDFF mapping and MOLLI‐based T 1 mapping using a combined PDFF‐T 1 phantom. Study Type Prospective phantom study. Phantom Commercial PDFF‐T 1 Phantom (Model 725) with varying PDFF (0%–30%) and T 1 (200–1400 ms) values. Field Strength/Sequence 1.5 T and 3 T multi‐echo, three‐dimensional spoiled‐gradient‐echo (SGRE) sequence for PDFF mapping, and MOLLI sequence (5(3)3 acquisition scheme) using two‐dimensional SGRE readouts for T 1 mapping across four centers and vendors. Assessment PDFF and T 1 maps were acquired using standardized protocols. PDFF maps were reconstructed locally, while T 1 maps were generated using a centralized algorithm. All maps were quantitatively analyzed by a single radiologist using standardized region‐of‐interest placement. Phantom temporal stability was assessed at one center across five sessions over 9 months (baseline, retest, 1 week, 6 and 9 months). Statistical Tests Intraclass correlation coefficients (ICC), reproducibility coefficients (RDC), and linear regression analysis were used. A p value < 0.05 was considered statistically significant. Results PDFF showed overall excellent reproducibility (ICC = 0.987, RDC = 3.7%), with increased variability at higher T 1 values (RDC up to 7.9% at T 1 = 1400 ms). T 1 mapping showed good reproducibility in the absence of fat (RDC 16–161 ms at PDFF = 0%), but moderate to poor reproducibility in the presence of fat, with RDC increasing up to 1553 ms at PDFF 30%. Temporal stability was excellent ICC ≥ 0.998 for both PDFF and T 1 , and RDC of 1.1%–1.3% for PDFF and 52–57 ms for T 1 . Data Conclusion This phantom study demonstrated high reproducibility of PDFF, whereas T 1 reproducibility deteriorated at higher fat and T 1 levels, underscoring the need for fat‐corrected T 1 mapping for reliable assessment of fibroinflammatory changes. Evidence Level N/A. Technical Efficacy Stage 1.
Comparative Precision of 3D MRE and 2D MRE for Measurement of Liver Stiffness in Adults with Severe Obesity
Müller, L, Ceriani, Lael , Harris, David T. , Wolfson, Tanya, Batakis, Danielle, Agni, Rashmi, Covarrubias, Yesenia, Pepin, Kay, Ehman, Richard L. , Heilman, Jeremiah, Panagiotopoulos, Nikolaos, Middleton, Michael S. , Martins, Vitor F. , Gamst, Anthony, Sappenfield, Ryan, Grunvald, Eduardo , Jacobsen, Garth R., Lidor, Anne O. , Goodman, James A. , Khoury, Sami B. , Müller, Lukas , Hamilton, Gavin , Martins, Vitor F , Sappenfield, Ryan , Grunvald, Eduardo , Funk, Luke M , Goodman, James A , Khoury, Sami B , Sirlin, Claude B. , Reeder, Scott B. , Ehman, Richard , Harris, David T. , Wolfson, Tanya, Batakis, Danielle, Agni, Rashmi , Heilman, Jeremiah A., Panagiotopoulos, Nikolaos , Goodman, James A , Sirlin, Claude B.

Radiology | May 5, 2026 | Volume: 319 | Issue: 2 | Pages: No page available

10.1148/radiol.253243 Get It

Compared with two-dimensional MR elastography (MRE), three-dimensional MRE demonstrated better test-retest repeatability, between–field-strength reproducibility, and between-day reproducibility at 3 T for measurement of liver stiffness in adults with severe obesity but failed more frequently.
Magnetic Resonance Imaging During a Pandemic: Recommendations by the ISMRM Safety Committee
Collins, Jeremy D. , Rowley, Howard A. , Leiner, Tim , Hood, Maureen N. , Dekkers, Ilona A. , Gulani, Vikas , Kopanoğlu, Emre , Reeder, Scott B. , Dekkers, Ilona , Tha, Khin , Kopanoglu, Emre , Collins, Jeremy , Leiner, Tim

Journal of Magnetic Resonance Imaging | December 20, 2021 | Volume: 55 | Issue: 5 | Pages: 1322-1339

10.1002/jmri.28006 Get It

The COVID‐19 pandemic highlighted the challenges delivering face‐to‐face patient care across healthcare systems. In particular the COVID‐19 pandemic challenged the imaging community to provide timely access to essential diagnostic imaging modalities while ensuring appropriate safeguards were in place for both patients and personnel. With increasing vaccine availability and greater prevalence of vaccination in communities worldwide we are finally emerging on the other side of the COVID‐19 pandemic. As we learned from our institutional and healthcare system responses to the pandemic, maintaining timely access to MR imaging is essential. Radiologists and other imaging providers partnered with their referring providers to ensure that timely access to advanced MR imaging was maintained. On behalf of the International Magnetic Resonance in Medicine (ISMRM) Safety Committee, this white paper is intended to serve as a guide for radiology departments, imaging centers, and other imaging specialists who perform MR imaging to refer to as we prepare for the next pandemic. Lessons learned including strategies to triage and prioritize MR imaging research during a pandemic are discussed.Level of Evidence5Technical EfficacyStage 5
Temperature‐corrected proton density fat fraction estimation using chemical shift‐encoded MRI in phantoms
Navaratna, Ruvini , Zhao, Ruiyang , Colgan, Timothy J. , Hu, Peng , Bydder, Mark , Bashir, Mustafa R. , Middleton, Michael S. , Serai, Suraj D. , Chenevert, Thomas L. , Smith, Mark A. , Henderson, Walter C. , Hamilton, Gavin , Shu, Yunhong , Tkach, Jean A. , Brittain, Jean H. , Hu, Houchun Harry , Serai, Suraj D , Shu, Yunhong , Trout, Andrew T , Hernando, Diego , Reeder, Scott B. , Hamilton, Gavin , Yokoo, Takeshi , Malyarenko, Dariya I. , Sirlin, Claude B. , Trout, Andrew T.

Magnetic Resonance in Medicine | February 11, 2021 | Volume: 86 | Issue: 1 | Pages: 69-81

10.1002/mrm.28669 Get It

PurposeChemical shift‐encoded MRI (CSE‐MRI) is well‐established to quantify proton density fat fraction (PDFF) as a quantitative biomarker of hepatic steatosis. However, temperature is known to bias PDFF estimation in phantom studies. In this study, strategies were developed and evaluated to correct for the effects of temperature on PDFF estimation through simulations, temperature‐controlled experiments, and a multi‐center, multi‐vendor phantom study.Theory and MethodsA technical solution that assumes and automatically estimates a uniform, global temperature throughout the phantom is proposed. Computer simulations modeled the effect of temperature on PDFF estimation using magnitude‐, complex‐, and hybrid‐based CSE‐MRI methods. Phantom experiments were performed to assess the temperature correction on PDFF estimation at controlled phantom temperatures. To assess the temperature correction method on a larger scale, the proposed method was applied to data acquired as part of a nine‐site multi‐vendor phantom study and compared to temperature‐corrected PDFF estimation using an a priori guess for ambient room temperature.ResultsSimulations and temperature‐controlled experiments show that as temperature deviates further from the assumed temperature, PDFF bias increases. Using the proposed correction method and a reasonable a priori guess for ambient temperature, PDFF bias and variability were reduced using magnitude‐based CSE‐MRI, across MRI systems, field strengths, protocols, and varying phantom temperature. Complex and hybrid methods showed little PDFF bias and variability both before and after correction.ConclusionCorrection for temperature reduces temperature‐related PDFF bias and variability in phantoms across MRI vendors, sites, field strengths, and protocols for magnitude‐based CSE‐MRI, even without a priori information about the temperature.
ACR guidance document on MR safe practices: Updates and critical information 2019
Greenberg, Todd D., Hoff, Michael N. , Gilk, Tobias , Och, Joseph, Rampulla, Tina L., Rogg, Jeffrey M. , Shellock, Frank G. , Watson, Robert E. , Weinreb, Jeffrey C. , Hernandez, Dina , Jackson, Edward F. , Kanal, Emanuel , McKinney, Alexander M. , Pedrosa, Iván , Reeder, Scott B.

Journal of Magnetic Resonance Imaging | July 29, 2019 | Volume: 51 | Issue: 2 | Pages: 331-338

10.1002/jmri.26880 Get It

The need for a guidance document on MR safe practices arose from a growing awareness of the MR environment's potential risks and adverse event reports involving patients, equipment, and personnel. Initially published in 2002, the American College of Radiology White Paper on MR Safety established de facto industry standards for safe and responsible practices in clinical and research MR environments. The most recent version addresses new sources of risk of adverse events, increases awareness of dynamic MR environments, and recommends that those responsible for MR medical director safety undergo annual MR safety training. With regular updates to these guidelines, the latest MR safety concerns can be accounted for to ensure a safer MR environment where dangers are minimized.Level of Evidence: 1Technical Efficacy Stage: 5J. Magn. Reson. Imaging 2020;51:331–338.
Value of MRI in medicine: More than just another test?
Kühl, Christiane , Desmond, Patricia , Gong, Qiyong , Gulani, Vikas , Lim, C. C. Tchoyoson , Pipe, James G. , Smits, Marion , Sodickson, Daniel K. , Tempany, Clare M. , Wang, Meiyun , Smits, Marion , Beek, Edwin J.R. van , Anzai, Yoshimi , Ehman, Richard L. , Gold, Garry Evan , Hall-Craggs, Margaret Anne , Leiner, Tim , Reeder, Scott B. , Reinhold, Caroline , Vargas, Hebert Alberto

Journal of Magnetic Resonance Imaging | August 26, 2018 | Volume: 49 | Issue: 7 | Pages: No page available

10.1002/jmri.26211 Get It

There is increasing scrutiny from healthcare organizations towards the utility and associated costs of imaging. MRI has traditionally been used as a high‐end modality, and although shown extremely important for many types of clinical scenarios, it has been suggested as too expensive by some. This editorial will try and explain how value should be addressed and gives some insights and practical examples of how value of MRI can be increased. It requires a global effort to increase accessibility, value for money, and impact on patient management. We hope this editorial sheds some light and gives some indications of where the field may wish to address some of its research to proactively demonstrate the value of MRI.Level of Evidence: 5Technical Efficacy: Stage 5J. Magn. Reson. Imaging 2019;49:e14–e25.
Standardized Approach for ROI-Based Measurements of Proton Density Fat Fraction and R2* in the Liver
Campo, Camilo A. , Bookwalter, Candice A., Pay, Andrew J. Van, Hernando, Diego , Schubert, Tilman B. , Reeder, Scott B.

American Journal of Roentgenology | July 13, 2017 | Volume: 209 | Issue: 3 | Pages: 592-603

10.2214/ajr.17.17812 Get It

Safety and technique of ferumoxytol administration for MRI
Vasanawala, Shreyas , Nguyen, Kim‐Lien , Hope, Michael D. , Bridges, Mellena D., Reeder, Scott B. , Bashir, Mustafa R. , Hope, Thomas A. , Reeder, Scott B.

Magnetic Resonance in Medicine | February 18, 2016 | Volume: 75 | Issue: 5 | Pages: 2107-2111

10.1002/mrm.26151 Get It

Advanced MRI Methods for Assessment of Chronic Liver Disease
Reeder, Scott B. , Taouli, Bachir , Ehman, Richard L. , Reeder, Scott B.

American Journal of Roentgenology | June 19, 2009 | Volume: 193 | Issue: 1 | Pages: 14-27

10.2214/ajr.09.2601 Get It