Compared with two-dimensional MR elastography (MRE), three-dimensional MRE demonstrated better test-retest repeatability, between–field-strength reproducibility, and between-day reproducibility at 3 T for measurement of liver stiffness in adults with severe obesity but failed more frequently.
Global Longitudinal Assessment of
MASLD
Using Magnetic Resonance Elastography (
GOLDMINE
): A Multi‐Center, International Prospective Cohort Study of Imag
ABSTRACT Background Metabolic dysfunction‐associated steatotic liver disease (MASLD) exhibits marked heterogeneity in fibrosis progression and liver‐related outcomes. Liver biopsy is not feasible for longitudinal risk stratification at scale, creating a need for validated non‐invasive biomarkers, particularly imaging biomarkers, that can predict clinically meaningful disease progression and liver‐related outcomes. Aims To describe the design and rationale of the GOLDMINE study, established to determine whether non‐invasive imaging biomarkers predict MASLD progression and liver‐related clinical outcomes. Methods GOLDMINE is an investigator‐initiated, multi‐centre, international longitudinal cohort enrolling up to 1000 adults with either biopsy‐proven MASLD or MASLD cirrhosis across the full fibrosis spectrum. Participants are recruited from 15 sites in the US and 4 international sites (Japan, Singapore and France). At baseline, participants undergo clinical phenotyping, vibration‐controlled transient elastography, and advanced magnetic resonance imaging (MRI), including proton‐density‐fat‐fraction and magnetic resonance elastography (MRE). MRI (and biospecimen banking) is repeated at 2‐year intervals (years 2 and 4), with annual follow‐up visits for up to 10 years. Baseline liver histology is centrally processed, digitized and reviewed by a single expert hepatopathologist; all MRI/MREs are centrally interpreted. Results The prespecified clinical outcomes include progression to cirrhosis, clinically significant portal hypertension, major adverse liver‐related outcomes (ascites, hepatic encephalopathy, portal hypertensive bleeding, liver transplantation/qualification), hepatocellular carcinoma, major adverse cardiovascular events, and all‐cause mortality, with independent central adjudication of all events. Conclusions GOLDMINE establishes a rigorously phenotyped MASLD cohort integrating centralized histology, advanced MRI‐based biomarkers, longitudinal biobanking, and adjudicated outcomes, providing a platform to validate imaging and blood‐based prognostic biomarkers in MASLD.
Temperature‐corrected proton density fat fraction estimation using chemical shift‐encoded MRI in phantoms
PurposeChemical shift‐encoded MRI (CSE‐MRI) is well‐established to quantify proton density fat fraction (PDFF) as a quantitative biomarker of hepatic steatosis. However, temperature is known to bias PDFF estimation in phantom studies. In this study, strategies were developed and evaluated to correct for the effects of temperature on PDFF estimation through simulations, temperature‐controlled experiments, and a multi‐center, multi‐vendor phantom study.Theory and MethodsA technical solution that assumes and automatically estimates a uniform, global temperature throughout the phantom is proposed. Computer simulations modeled the effect of temperature on PDFF estimation using magnitude‐, complex‐, and hybrid‐based CSE‐MRI methods. Phantom experiments were performed to assess the temperature correction on PDFF estimation at controlled phantom temperatures. To assess the temperature correction method on a larger scale, the proposed method was applied to data acquired as part of a nine‐site multi‐vendor phantom study and compared to temperature‐corrected PDFF estimation using an a priori guess for ambient room temperature.ResultsSimulations and temperature‐controlled experiments show that as temperature deviates further from the assumed temperature, PDFF bias increases. Using the proposed correction method and a reasonable a priori guess for ambient temperature, PDFF bias and variability were reduced using magnitude‐based CSE‐MRI, across MRI systems, field strengths, protocols, and varying phantom temperature. Complex and hybrid methods showed little PDFF bias and variability both before and after correction.ConclusionCorrection for temperature reduces temperature‐related PDFF bias and variability in phantoms across MRI vendors, sites, field strengths, and protocols for magnitude‐based CSE‐MRI, even without a priori information about the temperature.
Magnetic resonance elastography measured shear stiffness as a biomarker of fibrosis in pediatric nonalcoholic fatty liver disease
Magnetic resonance elastography (MRE) is a promising technique for noninvasive assessment of fibrosis, a major determinant of outcome in nonalcoholic fatty liver disease (NAFLD). However, data in children are limited. The purpose of this study was to determine the accuracy of MRE for the detection of fibrosis and advanced fibrosis in children with NAFLD and to assess agreement between manual and novel automated reading methods. We performed a prospective, multicenter study of two‐dimensional (2D) MRE in children with NAFLD. MR elastograms were analyzed manually at two reading centers, and using a new automated technique. Analysis using each approach was done independently. Correlations were determined between MRE analysis methods and fibrosis stage. Thresholds for classifying the presence of fibrosis and of advanced fibrosis were computed and cross‐validated. In 90 children with a mean age of 13.1 ± 2.4 years, median hepatic stiffness was 2.35 kPa. Stiffness values derived by each reading center were strongly correlated with each other (r = 0.83). All three analyses were significantly correlated with fibrosis stage (center 1, ρ = 0.53; center 2, ρ = 0.55; and automated analysis, ρ = 0.52; P < 0.001). Overall cross‐validated accuracy for detecting any fibrosis was 72.2% for all methods (95% confidence interval [CI], 61.8%‐81.1%). Overall cross‐validated accuracy for assessing advanced fibrosis was 88.9% (95% CI, 80.5%‐94.5%) for center 1, 90.0% (95% CI, 81.9%‐95.3%) for center 2, and 86.7% (95% CI, 77.9%‐92.9%) for automated analysis. Conclusion : 2D MRE can estimate hepatic stiffness in children with NAFLD. Further refinement and validation of automated analysis techniques will be an important step in standardizing MRE. How to best integrate MRE into clinical protocols for the assessment of NAFLD in children will require prospective evaluation. (H epatology 2017;66:1474–1485)