Repeatability and Reproducibility Assessment of the Apparent Diffusion Coefficient in the Prostate: A Trial of the ECOG‐ACRIN Research Group (ACRIN 6701)
Boss, Michael A. , Kim, Eun‐Hee , Flamini, Dena, Englander, Sarah, Sundaram, Karthik M. , Gumpeni, Naveen , Choi, Haesun , Froemming, Adam T. , Persigehl, Thorsten , Chenevert, Thomas L. , Rosen, Mark, Choi, Haesun , Boss, Michael A , Snyder, Bradley S. , Palmer, Suzanne L. , Davenport, Matthew S. , Malyarenko, Dariya I.

Journal of Magnetic Resonance Imaging | February 10, 2022 | Volume: 56 | Issue: 3 | Pages: 668-679

10.1002/jmri.28093 Get It

BackgroundUncertainty regarding the reproducibility of the apparent diffusion coefficient (ADC) hampers the use of quantitative diffusion‐weighted imaging (DWI) in evaluation of the prostate with magnetic resonance imaging MRI. The quantitative imaging biomarkers alliance (QIBA) profile for quantitative DWI claims a within‐subject coefficient of variation (wCV) for prostate lesion ADC of 0.17. Improved understanding of ADC reproducibility would aid the use of quantitative diffusion in prostate MRI evaluation.PurposeEvaluation of the repeatability (same‐day) and reproducibility (multi‐day) of whole‐prostate and focal‐lesion ADC assessment in a multi‐site setting.Study TypeProspective multi‐institutional.SubjectsTwenty‐nine males, ages 53 to 80 (median 63) years, following diagnosis of prostate cancer, 10 with focal lesions.Field Strength/Sequence3T, single‐shot spin‐echo diffusion‐weighted echo‐planar sequence with four b‐values.AssessmentSites qualified for the study using an ice‐water phantom with known ADC. Readers performed DWI analyses at visit 1 (“V1”) and visit 2 (“V2,” 2–14 days after V1), where V2 comprised scans before (“V2pre”) and after (“V2post”) a “coffee‐break” interval with subject removal and repositioning. A single reader segmented the whole prostate. Two readers separately placed region‐of‐interests for focal lesions.Statistical TestsReproducibility and repeatability coefficients for whole prostate and focal lesions derived from median pixel ADC. We estimated the wCV and 95% confidence interval using a variance stabilizing transformation and assessed interreader reliability of focal lesion ADC using the intraclass correlation coefficient (ICC).ResultsThe ADC biases from b0–b600 and b0–b800 phantom scans averaged 1.32% and 1.44%, respectively; mean b‐value dependence was 0.188%. Repeatability and reproducibility of whole prostate median pixel ADC both yielded wCVs of 0.033 (N = 29). In 10 subjects with an evaluable focal lesion, the individual reader wCVs were 0.148 and 0.074 (repeatability) and 0.137 and 0.078 (reproducibility). All time points demonstrated good to excellent interreader reliability for focal lesion ADC (ICCV1 = 0.89; ICCV2pre = 0.76; ICCV2post = 0.94).Data ConclusionThis study met the QIBA claim for prostate ADC. Test–retest repeatability and multi‐day reproducibility were largely equivalent. Interreader reliability for focal lesion ADC was high across time points.Level of Evidence1Technical EfficacyStage 2TOC CategoryPelvis
Temperature‐corrected proton density fat fraction estimation using chemical shift‐encoded MRI in phantoms
Navaratna, Ruvini , Zhao, Ruiyang , Colgan, Timothy J. , Hu, Peng , Bydder, Mark , Bashir, Mustafa R. , Middleton, Michael S. , Serai, Suraj D. , Chenevert, Thomas L. , Smith, Mark A. , Henderson, Walter C. , Hamilton, Gavin , Shu, Yunhong , Tkach, Jean A. , Brittain, Jean H. , Hu, Houchun Harry , Serai, Suraj D , Shu, Yunhong , Trout, Andrew T , Hernando, Diego , Reeder, Scott B. , Hamilton, Gavin , Yokoo, Takeshi , Malyarenko, Dariya I. , Sirlin, Claude B. , Trout, Andrew T.

Magnetic Resonance in Medicine | February 11, 2021 | Volume: 86 | Issue: 1 | Pages: 69-81

10.1002/mrm.28669 Get It

PurposeChemical shift‐encoded MRI (CSE‐MRI) is well‐established to quantify proton density fat fraction (PDFF) as a quantitative biomarker of hepatic steatosis. However, temperature is known to bias PDFF estimation in phantom studies. In this study, strategies were developed and evaluated to correct for the effects of temperature on PDFF estimation through simulations, temperature‐controlled experiments, and a multi‐center, multi‐vendor phantom study.Theory and MethodsA technical solution that assumes and automatically estimates a uniform, global temperature throughout the phantom is proposed. Computer simulations modeled the effect of temperature on PDFF estimation using magnitude‐, complex‐, and hybrid‐based CSE‐MRI methods. Phantom experiments were performed to assess the temperature correction on PDFF estimation at controlled phantom temperatures. To assess the temperature correction method on a larger scale, the proposed method was applied to data acquired as part of a nine‐site multi‐vendor phantom study and compared to temperature‐corrected PDFF estimation using an a priori guess for ambient room temperature.ResultsSimulations and temperature‐controlled experiments show that as temperature deviates further from the assumed temperature, PDFF bias increases. Using the proposed correction method and a reasonable a priori guess for ambient temperature, PDFF bias and variability were reduced using magnitude‐based CSE‐MRI, across MRI systems, field strengths, protocols, and varying phantom temperature. Complex and hybrid methods showed little PDFF bias and variability both before and after correction.ConclusionCorrection for temperature reduces temperature‐related PDFF bias and variability in phantoms across MRI vendors, sites, field strengths, and protocols for magnitude‐based CSE‐MRI, even without a priori information about the temperature.