ABSTRACT Background and Aims Clinically significant portal hypertension (CSPH; hepatic venous pressure gradient (HVPG) ≥ 10 mmHg) is a severe complication of chronic liver disease, with increased risk of variceal bleeding and liver decompensation (at HVPG ≥ 12 mmHg). This study evaluated the performance of multiparametric (mp)MRI for diagnosing CSPH and predicting liver decompensation, compared to ultrasound‐based shear wave elastography (SWE) and blood tests. Methods In this prospective single‐centre study (2018–2022), 59 patients (M 30, mean age 52.7 years) underwent mpMRI and HVPG measurement, with an average interval of 32 ± 31 days. The mpMRI protocol included 2D/3D MR elastography (MRE), T 1 /proprietary iron‐compensated T 1 (cT 1 )/T 1ρ mapping, gadoxetate‐enhanced dynamic contrast‐enhanced MRI (DCE‐MRI) of the liver and spleen, SWE and blood tests. Statistical analyses included Mann–Whitney U tests, ROC analysis, logistic regression and Cox proportional hazards models. Results CSPH was present in 13 patients (22%). Several MRI parameters showed high diagnostic performance for CSPH (AUC ≥ 0.8), with spleen stiffness‐2D MRE (AUC 0.88, 95% confidence interval (CI) 0.78–0.98) and liver uptake on DCE‐MRI (AUC 0.83, 95% CI 0.70–0.96) performing best, while SWE had AUCs of 0.63 (95% CI 0.45–0.81) for liver and 0.67 (95% CI 0.44–0.89) for spleen. Combining spleen stiffness‐2D MRE and liver uptake achieved an AUC of 0.93 (95% CI 0.86–1.00) for diagnosing CSPH. For predicting decompensation, spleen stiffness‐3D MRE and liver uptake rate had AUCs of 0.83 (95% CI 0.68–0.99) and 0.83 (95% CI 0.70–0.95), respectively, outperforming SWE. Conclusions Spleen stiffness measured with MRE combined with gadoxetate liver uptake (measured with DCE‐MRI) can diagnose CSPH and predict liver decompensation, with superior performance compared to SWE. Trial Registration ClinicalTrials.gov identifier: NCT03436550
Reply: Imaging-based noninvasive liver disease assessment for staging liver fibrosis in chronic liver disease: A systematic review supporting the AASLD Practice Guideline
Imaging-based noninvasive liver disease assessment for staging liver fibrosis in chronic liver disease: A systematic review supporting the AASLD Practice Guideline
Background and Aims: Transient elastography (TE), shear wave elastography, and/or magnetic resonance elastography (MRE), each providing liver stiffness measurement (LSM), are the most studied imaging-based noninvasive liver disease assessment (NILDA) techniques. To support the American Association for the Study of Liver Diseases guidelines on NILDA, we summarized the evidence on the accuracy of these LSM methods to stage liver fibrosis (F). Approach and Results: A comprehensive search for studies assessing LSM by TE, shear wave elastography, or MRE for the identification of significant fibrosis (F2-4), advanced fibrosis (F3-4), or cirrhosis (F4), using histopathology as the standard of reference by liver disease etiology in adults or children from inception to April 2022 was performed. We excluded studies with <50 patients with a single disease entity and mixed liver disease etiologies (with the exception of HCV/HIV coinfection). Out of 9447 studies, 240 with 61,193 patients were included in this systematic review. In adults, sensitivities for the identification of F2-4 ranged from 51% to 95%, for F3-4 from 70% to 100%, and for F4 from 60% to 100% across all techniques/diseases, whereas specificities ranged from 36% to 100%, 74% to 100%, and 67% to 99%, respectively. The largest body of evidence available was for TE; MRE appeared to be the most accurate method. Imaging-based NILDA outperformed blood-based NILDA in most comparisons, particularly for the identification of F3-4/F4. In the pediatric population, imaging-based NILDA is likely as accurate as in adults. Conclusions: LSM from TE, shear wave elastography, and MRE shows acceptable to outstanding accuracy for the detection of liver fibrosis across various liver disease etiologies. Accuracy increased from F2-4 to F3-4 and was the highest for F4. Further research is needed to better standardize the use of imaging-based NILDA, particularly in pediatric liver diseases.
AASLD Practice Guideline on noninvasive liver disease assessment of portal hypertension
Objective The aim of this study was to compare 2-dimensional (2D) gradient recalled echo (GRE) and 2D spin echo echoplanar imaging (SE-EPI) magnetic resonance elastography (MRE) sequences of the liver in terms of image quality and quantitative liver stiffness (LS) measurement. Materials and Methods This prospective study involved 50 consecutive subjects (male/female, 33/17; mean age, 58 years) who underwent liver magnetic resonance imaging at 3.0 T including 2 MRE sequences, 2D GRE, and 2D SE-EPI (acquisition time 56 vs 16 seconds, respectively). Image quality scores were assessed by 2 independent observers based on wave propagation and organ coverage on the confidence map (range, 0–15). A third observer measured LS on stiffness maps (in kilopascal). Mean LS values, regions of interest size (based on confidence map), and image quality scores between SE-EPI and GRE-MRE were compared using paired nonparametric Wilcoxon test. Reproducibility of LS values between the 2 sequences was assessed using intraclass coefficient correlation, coefficient of variation, and Bland-Altman limits of agreement. T2* effect on image quality was assessed using partial Spearman correlation. Results There were 4 cases of failure with GRE-MRE and none with SE-EPI-MRE. Image quality scores and region of interest size were significantly higher using SE-EPI-MRE versus GRE-MRE (P < 0.0001 for both measurements and observers). Liver stiffness measurements were not significantly different between the 2 sequences (3.75 ± 1.87 kPa vs 3.55 ± 1.51 kPa, P = 0.062), were significantly correlated (intraclass coefficient correlation, 0.909), and had excellent reproducibility (coefficient of variation, 10.2%; bias, 0.023; Bland-Altman limits of agreement, −1.19; 1.66 kPa). Image quality scores using GRE-MRE were significantly correlated with T2* while there was no correlation for SE-EPI-MRE. Conclusions Our data suggest that SE-EPI-MRE may be a better alternative to GRE-MRE. The diagnostic performance of SE-EPI-MRE for detection of liver fibrosis needs to be assessed in a future study.
Interplatform reproducibility of liver and spleen stiffness measured with MR elastography
PurposeTo assess interplatform reproducibility of liver stiffness (LS) and spleen stiffness (SS) measured with magnetic resonance elastography (MRE) based on a 2D gradient echo (GRE) sequence.Materials and MethodsThis prospective Health Insurance Portability and Accountability Act (HIPAA)‐compliant and Institutional Review Board (IRB)‐approved study involved 12 subjects (five healthy volunteers and seven patients with liver disease). A multislice 2D‐GRE‐based MRE sequence was performed using two systems from different vendors (3.0T GE and 1.5T Siemens) on the same day. Two independent observers measured LS and SS on confidence maps. Bland–Altman analysis (with coefficient of reproducibility, CR), coefficient of variability (CV), and intraclass correlation (ICC) were used to analyze interplatform, intra‐ and interobserver variability. Human data were validated using a gelatin‐based phantom.ResultsThere was excellent reproducibility of phantom stiffness measurement (CV 4.4%). Mean LS values were 3.44–3.48 kPa and 3.62–3.63 kPa, and mean SS values were 7.54–7.91 kPa and 8.40–8.85 kPa at 3.0T and 1.5T for observers 1 and 2, respectively. The mean CVs between platforms were 9.2%–11.5% and 13.1%–14.4% for LS and SS, respectively, for observers 1 and 2. There was excellent interplatform reproducibility (ICC >0.88 and CR <36.2%) for both LS and SS, and excellent intra‐ and interobserver reproducibility (intraobserver: ICC >0.99, CV <2.1%, CR <6.6%; interobserver: ICC >0.97, CV and CR <16%).ConclusionThis study demonstrates that 2D‐GRE MRE provides platform‐ and observer‐independent LS and SS measurements. J. Magn. Reson. Imaging 2016;43:1064–1072.
Advanced MRI Methods for Assessment of Chronic Liver Disease