Center for Biomedical Imaging, Center for Advanced Innovation and Imaging Research (CAIIR), Department of Radiology, NYU Langone Health, 660 1st Ave, New York, NY 10016.
Citations 4
Evaluating Breast Cancer Intravoxel Incoherent Motion MRI Biomarkers across Software Platforms
Intravoxel incoherent motion MRI parameters derived from two software packages demonstrated diagnostic value for breast cancer, with multivariable combinations of histogram metrics achieving high diagnostic accuracy.
Interplatform reproducibility of liver and spleen stiffness measured with MR elastography
PurposeTo assess interplatform reproducibility of liver stiffness (LS) and spleen stiffness (SS) measured with magnetic resonance elastography (MRE) based on a 2D gradient echo (GRE) sequence.Materials and MethodsThis prospective Health Insurance Portability and Accountability Act (HIPAA)‐compliant and Institutional Review Board (IRB)‐approved study involved 12 subjects (five healthy volunteers and seven patients with liver disease). A multislice 2D‐GRE‐based MRE sequence was performed using two systems from different vendors (3.0T GE and 1.5T Siemens) on the same day. Two independent observers measured LS and SS on confidence maps. Bland–Altman analysis (with coefficient of reproducibility, CR), coefficient of variability (CV), and intraclass correlation (ICC) were used to analyze interplatform, intra‐ and interobserver variability. Human data were validated using a gelatin‐based phantom.ResultsThere was excellent reproducibility of phantom stiffness measurement (CV 4.4%). Mean LS values were 3.44–3.48 kPa and 3.62–3.63 kPa, and mean SS values were 7.54–7.91 kPa and 8.40–8.85 kPa at 3.0T and 1.5T for observers 1 and 2, respectively. The mean CVs between platforms were 9.2%–11.5% and 13.1%–14.4% for LS and SS, respectively, for observers 1 and 2. There was excellent interplatform reproducibility (ICC >0.88 and CR <36.2%) for both LS and SS, and excellent intra‐ and interobserver reproducibility (intraobserver: ICC >0.99, CV <2.1%, CR <6.6%; interobserver: ICC >0.97, CV and CR <16%).ConclusionThis study demonstrates that 2D‐GRE MRE provides platform‐ and observer‐independent LS and SS measurements. J. Magn. Reson. Imaging 2016;43:1064–1072.
Improved Efficiency of CT Interpretation Using an Automated Lung Nodule Matching Program