Detectability of Small Low-Attenuation Lesions With Deep Learning CT Image Reconstruction: A 24-Reader Phantom Study
Toia, Giuseppe V. , Zamora, D , Singleton, Michael, Shuman, William P. , Kanal, Kalpana M. , Mileto, Achille , Singleton, Michael, Liu, Arthur , Tan, Edward, Leng, Shuai

American Journal of Roentgenology | September 21, 2022 | Volume: 220 | Issue: 2 | Pages: 283-295

10.2214/ajr.22.28407 Get It

Findings of the AAPM Ad Hoc committee on magnetic resonance imaging in radiation therapy: Unmet needs, opportunities, and recommendations
McGee, Kiaran P. , Tyagi, Neelam , Bayouth, John E. , Fallone, B. G. , Glide‐Hurst, Carri , Goerner, F, Green, Olga L., Kim, Taeho , Paulson, E.S. , Yanasak, N. E. , Goodwin, James, Jordan, David W. , Hugo, Geoffrey D., Balter, James M. , Kanal, Kalpana M. , Hazle, John D. , Pelc, Norbert J. , Cao, Minsong , Jackson, Edward F. , Dieterich, Sonja , Bernstein, Matt A.

Medical Physics | July 7, 2021 | Volume: 48 | Issue: 8 | Pages: 4523-4531

10.1002/mp.14996 Get It

The past decade has seen the increasing integration of magnetic resonance (MR) imaging into radiation therapy (RT). This growth can be contributed to multiple factors, including hardware and software advances that have allowed the acquisition of high‐resolution volumetric data of RT patients in their treatment position (also known as MR simulation) and the development of methods to image and quantify tissue function and response to therapy. More recently, the advent of MR‐guided radiation therapy (MRgRT) ‐ achieved through the integration of MR imaging systems and linear accelerators ‐ has further accelerated this trend. As MR imaging in RT techniques and technologies, such as MRgRT, gain regulatory approval worldwide, these systems will begin to propagate beyond tertiary care academic medical centers and into more community‐based health systems and hospitals, creating new opportunities to provide advanced treatment options to a broader patient population. Accompanying these opportunities are unique challenges related to their adaptation, adoption, and use including modification of hardware and software to meet the unique and distinct demands of MR imaging in RT, the need for standardization of imaging techniques and protocols, education of the broader RT community (particularly in regards to MR safety) as well as the need to continue and support research, and development in this space. In response to this, an ad hoc committee of the American Association of Physicists in Medicine (AAPM) was formed to identify the unmet needs, roadblocks, and opportunities within this space. The purpose of this document is to report on the major findings and recommendations identified. Importantly, the provided recommendations represent the consensus opinions of the committee’s membership, which were submitted in the committee's report to the AAPM Board of Directors. In addition, AAPM ad hoc committee reports differ from AAPM task group reports in that ad hoc committee reports are neither reviewed nor ultimately approved by the committee’s parent groups, including at the council and executive committee level. Thus, the recommendations given in this summary should not be construed as being endorsed by or official recommendations from the AAPM.
Estimation of patient skin dose in fluoroscopy: summary of a joint report by AAPM TG357 and EFOMP
Andersson, Jonas , Bednarek, Daniel R. , Boltz, Thomas, Bosmans, Hilde , Gislason‐Lee, Amber J., Granberg, Christoffer, Hellström, Max , Kanal, Kalpana M. , McDonagh, Ed, Paden, Robert G., Pavlicek, William , Khodadadegan, Yasaman, Torresin, A. , Trianni, Annalisa , Zamora, D , Paden, Robert, Bolch, Wesley E.

Medical Physics | April 30, 2021 | Volume: 48 | Issue: 7 | Pages: No page available

10.1002/mp.14910 Get It

BackgroundPhysicians use fixed C‐arm fluoroscopy equipment with many interventional radiological and cardiological procedures. The associated effective dose to a patient is generally considered low risk, as the benefit‐risk ratio is almost certainly highly favorable. However, X‐ray‐induced skin injuries may occur due to high absorbed patient skin doses from complex fluoroscopically guided interventions (FGI). Suitable action levels for patient‐specific follow‐up could improve the clinical practice.There is a need for a refined metric regarding follow‐up of X‐ray‐induced patient injuries and the knowledge gap regarding skin dose‐related patient information from fluoroscopy devices must be filled. The most useful metric to indicate a risk of erythema, epilation or greater skin injury that also includes actionable information is the peak skin dose, that is, the largest dose to a region of skin.Materials and MethodsThe report is based on a comprehensive review of best practices and methods to estimate peak skin dose found in the scientific literature and situates the importance of the Digital Imaging and Communication in Medicine (DICOM) standard detailing pertinent information contained in the Radiation Dose Structured Report (RDSR) and DICOM image headers for FGI devices. Furthermore, the expertise of the task group members and consultants have been used to bridge and discuss different methods and associated available DICOM information for peak skin dose estimation.ResultsThe report contributes an extensive summary and discussion of the current state of the art in estimating peak skin dose with FGI procedures with regard to methodology and DICOM information. Improvements in skin dose estimation efforts with more refined DICOM information are suggested and discussed.ConclusionsThe endeavor of skin dose estimation is greatly aided by the continuing efforts of the scientific medical physics community, the numerous technology enhancements, the dose‐controlling features provided by the FGI device manufacturers, and the emergence and greater availability of the DICOM RDSR. Refined and new dosimetry systems continue to evolve and form the infrastructure for further improvements in accuracy. Dose‐related content and information systems capable of handling big data are emerging for patient dose monitoring and quality assurance tools for large‐scale multihospital enterprises.
U.S. Diagnostic Reference Levels and Achievable Doses for 10 Adult CT Examinations
Kanal, Kalpana M. , Butler, Priscilla F. , Sengupta, Debapriya , Bhargavan, Mythreyi , Coombs, Laura P. , Morin, Richard L. , Bhargavan-Chatfield, Mythreyi

Radiology | February 21, 2017 | Volume: 284 | Issue: 1 | Pages: 120-133

10.1148/radiol.2017161911 Get It