BackgroundPhysicians use fixed C‐arm fluoroscopy equipment with many interventional radiological and cardiological procedures. The associated effective dose to a patient is generally considered low risk, as the benefit‐risk ratio is almost certainly highly favorable. However, X‐ray‐induced skin injuries may occur due to high absorbed patient skin doses from complex fluoroscopically guided interventions (FGI). Suitable action levels for patient‐specific follow‐up could improve the clinical practice.There is a need for a refined metric regarding follow‐up of X‐ray‐induced patient injuries and the knowledge gap regarding skin dose‐related patient information from fluoroscopy devices must be filled. The most useful metric to indicate a risk of erythema, epilation or greater skin injury that also includes actionable information is the peak skin dose, that is, the largest dose to a region of skin.Materials and MethodsThe report is based on a comprehensive review of best practices and methods to estimate peak skin dose found in the scientific literature and situates the importance of the Digital Imaging and Communication in Medicine (DICOM) standard detailing pertinent information contained in the Radiation Dose Structured Report (RDSR) and DICOM image headers for FGI devices. Furthermore, the expertise of the task group members and consultants have been used to bridge and discuss different methods and associated available DICOM information for peak skin dose estimation.ResultsThe report contributes an extensive summary and discussion of the current state of the art in estimating peak skin dose with FGI procedures with regard to methodology and DICOM information. Improvements in skin dose estimation efforts with more refined DICOM information are suggested and discussed.ConclusionsThe endeavor of skin dose estimation is greatly aided by the continuing efforts of the scientific medical physics community, the numerous technology enhancements, the dose‐controlling features provided by the FGI device manufacturers, and the emergence and greater availability of the DICOM RDSR. Refined and new dosimetry systems continue to evolve and form the infrastructure for further improvements in accuracy. Dose‐related content and information systems capable of handling big data are emerging for patient dose monitoring and quality assurance tools for large‐scale multihospital enterprises.
Sample content of kinesthetic educational training: Reducing scattered X‐ray exposures to interventional physician operators of fluoroscopy
AbstractContent used by Medical Physicists for fluoroscopy safety training to staff is deliverable via several formats, that is, online content or a live audience slide presentations. Here, we share one example of a kinesthetic (live, hands‐on simulation) educational program in use at our facility for some time (~10 years). In this example, the format and content specifically target methods of reducing physician operator exposures from scattered x rays. A kinesthetic format identifies and promotes the adoption of exposure‐reducing behaviors. Key kinesthetic elements of this type of training include: physician hands‐on measurements of radiation levels at locations specific to their standing positions (e.g., primary arterial access points) in the room using handheld exposure rate meters, measurement of exposure rate reduction to physicians provided by using personal protective equipment, that is, wearable aprons, hanging lead drapes, and pull‐down shields. Physician choice of procedure‐specific tableside selectable controls affecting exposure rate from optional fluoroscopy, Cine or digital subtraction angiography (DSA), along with comparative measured contribution to physician exposure is demonstrated. The inverse square exposure rate reduction to physicians when stepping back from the table during DSA is a key observation. Kinesthetic simulations in the rooms used by physicians have been found to provide the highest level of understanding giving rise to adoption of practices that are impactful for physicians. Specific training scripts are in place for physician sub‐specialization in interventional radiology, cardiology, neurosurgery, vascular surgery, and gastroenterology. This training is used for new physician staff while classroom presentations (whose content mimics in room training) are used with staff who have had previously had in room training.
An anthropomorphic beating heart phantom for cardiac X‐ray CT imaging evaluation
The current work describes an anthropomorphic beating heart phantom constructed as a tool for the assessment of technological advances in cardiac X‐ray computed tomography (CT). The phantom is comprised of a thorax, a compressor system, an ECG system, a beating heart with tortuous coronary arteries, and the option to add or remove pathologies such as aberrant beats, stents, and plaques. Initial trials with the phantom have shown its utility to assess temporal resolution, spatial resolution, radiation dose, iodine contrast, stents, and plaques.PACS numbers: 87.59.Fm, 87.57.Ce
Reducing Body CT Radiation Dose: Beyond Just Changing the Numbers
Abdominal CT: Comparison of Low-Dose CT With Adaptive Statistical Iterative Reconstruction and Routine-Dose CT With Filtered Back Projection in 53 Patients