Effect of titanium endoprostheses on bone mineral density measurements, using quantitative computed tomography
Markel, Mark D., Morin, Richard L. , Roy, Robert G., Gottsauner‐Wolf, Florian, Chao, Edmund Y.S.

American Journal of Veterinary Research | January 24, 2024 | Volume: 53 | Issue: 11 | Pages: 2105-2108

10.2460/ajvr.1992.53.11.2105 Get It

Summary Quantitative computed tomography has been used extensively to measure bone mineral density; particularly in the vertebral column and in the proximal portion of the femur in human beings with osteoporosis. Other potential applications of this technique include evaluation of bone adjacent to metallic endoprostheses and evaluation of fractures as they heal. Unfortunately, metal causes severe image degradation, principally seen as starburst streaking. One method used to decrease these artifacts is by imaging less-attenuating materials, such as titanium alloy. Titanium decreases image degradation sufficiently to allow accurate determination of the geometric properties of cadaveric bone. In our study, the effect of a titanium segmental endoprosthesis on bone mineral density measurement was determined by use of bone specimens from dogs and calibration standards. Titanium decreased the bone mineral density of calibration solutions from 6.8 (500 mg/cm3) to 17.7% (250 mg/cm3), and increased bone mineral density of cortical bone by 5.3%. Titanium did not affect the repeatability of these scans, indicating that the error caused by titanium was systematic and can be corrected. Our data were suggestive that quantitative computed tomography can be used to measure bone mineral density of cortical bone adjacent to titanium endoprostheses, with a predictable increase in density measurement.
Multiplanar quantitative computed tomography for bone mineral analysis in dogs
Markel, Mark D., Morin, Richard L. , Wikenheiser, Mark A., Robb, Richard A., Chao, Edmund Y.S.

American Journal of Veterinary Research | January 24, 2024 | Volume: 52 | Issue: 9 | Pages: 1479-1483

10.2460/ajvr.1991.52.09.1479 Get It

Summary The purpose of this study was to determine the precision and accuracy of quantitative computed tomography bone mineral analysis in dogs in coronally reconstructed images. Nonhomogeneous tissues, such as bones with fractures or deformities, may be better analyzed if multiplanar reconstruction of the transaxial data could be performed without degradation of information. Our analysis demonstrated that coronal reconstruction of quantitative-computed tomography data was precise (1.2 to 4.7%) and accurate (1.3 to 7.5%) in vitro. The technique displays high-quality images, which can be analyzed at any location within the volume scanned. Quantitative computed tomography of canine osteotomy healing in vivo accurately determined bone mineral density of selected regions of interest. Bone mineral density correlated highly with calcium content of the tissue (R2 = 0.76, P < 0.0001).
In Vivo Comparison of Radiation Exposure in Third-Generation vs Second-Generation Dual-Source Dual-Energy CT for Imaging Urinary Calculi
Lam, Jonathan P. , Alexander, Lauren F. , William, Haley E., Hodge, David O. , Kofler, James M., Morin, Richard L. , Thiel, David D. , Cernigliaro, Joseph G. , Alexander, Lauren F

Journal of Endourology | April 16, 2021 | Volume: 35 | Issue: 11 | Pages: 1581-1585

10.1089/end.2021.0103 Get It

Purpose: To investigate the potential for decreasing radiation dose when utilizing a third-generation vs second-generation dual-source dual-energy CT (dsDECT) scanner, while maintaining diagnostic image quality and acceptable image noise. Materials and Methods : Retrospective analysis of patients who underwent dsDECT for clinical suspicion of urolithiasis from October 2, 2017, to September 5, 2018. Patient demographics, body mass index, abdominal diameter, scanning parameters, and CT dose index volume (CTDIvol) were recorded. Image quality was assessed by measuring the attenuation and standard deviation (SD) regions of interest in the aorta and in the bladder. Image noise was determined by averaging the SD at both levels. Patients were excluded if they had not undergone both third- and second-generation dual-energy CT (DECT), time between DECT was more than 2 years, or scan parameters were outside the standard protocol. Results: A total of 117 patients met the inclusion criteria. Examinations performed on a third-generation DECT had an average CTDIvol 12.3 mGy, while examinations performed on a second-generation DECT had an average CTDIvol 13.3 mGy ( p < 0.001). Average image noise was significantly lower for the third-generation DECT (SD = 10.3) compared with the second-generation DECT (SD = 13.9) ( p < 0.001). Conclusions: The third-generation dsDECT scanners can simultaneously decrease patient radiation dose and decrease image noise compared with second-generation DECT. These reductions in radiation exposure can be particularly important in patients with urinary stone disease who often require repeated imaging to evaluate for stone development and recurrence as well as treatment assessment.
Image guidance doses delivered during radiotherapy: Quantification, management, and reduction: Report of the AAPM Therapy Physics Committee Task Group 180
Ding, G , Alaei, Parham , Curran, Bruce, Flynn, Ryan T. , Gossman, Michael S., Mackie, T, Miften, Moyed, Morin, Richard L. , Xu, Xiaobin , Morin, Richard, Zhu, Timothy C. , Flynn, Ryan T

Medical Physics | February 22, 2018 | Volume: 45 | Issue: 5 | Pages: No page available

10.1002/mp.12824 Get It

BackgroundWith radiotherapy having entered the era of image guidance, or image‐guided radiation therapy (IGRT), imaging procedures are routinely performed for patient positioning and target localization. The imaging dose delivered may result in excessive dose to sensitive organs and potentially increase the chance of secondary cancers and, therefore, needs to be managed.AimsThis task group was charged with: a) providing an overview on imaging dose, including megavoltage electronic portal imaging (MV EPI), kilovoltage digital radiography (kV DR), Tomotherapy MV‐CT, megavoltage cone‐beam CT (MV‐CBCT) and kilovoltage cone‐beam CT (kV‐CBCT), and b) providing general guidelines for commissioning dose calculation methods and managing imaging dose to patients.Materials & MethodsWe briefly review the dose to radiotherapy (RT) patients resulting from different image guidance procedures and list typical organ doses resulting from MV and kV image acquisition procedures.ResultsWe provide recommendations for managing the imaging dose, including different methods for its calculation, and techniques for reducing it. The recommended threshold beyond which imaging dose should be considered in the treatment planning process is 5% of the therapeutic target dose.DiscussionAlthough the imaging dose resulting from current kV acquisition procedures is generally below this threshold, the ALARA principle should always be applied in practice. Medical physicists should make radiation oncologists aware of the imaging doses delivered to patients under their care.ConclusionBalancing ALARA with the requirement for effective target localization requires that imaging dose be managed based on the consideration of weighing risks and benefits to the patient.
Spatial Distribution of Iron Within the Normal Human Liver Using Dual-Source Dual-Energy CT Imaging
Abadia, Andres F. , Grant, Katharine L., Carey, Kathleen E., Morin, Richard L. , Bolch, Wesley E.

Investigative Radiology | May 31, 2017 | Volume: 52 | Issue: 11 | Pages: 693-700

10.1097/rli.0000000000000393 Get It

Objectives Explore the potential of dual-source dual-energy (DSDE) computed tomography (CT) to retrospectively analyze the uniformity of iron distribution and establish iron concentration ranges and distribution patterns found in healthy livers. Materials and Methods Ten mixtures consisting of an iron nitrate solution and deionized water were prepared in test tubes and scanned using a DSDE 128-slice CT system. Iron images were derived from a 3-material decomposition algorithm (optimized for the quantification of iron). A conversion factor (mg Fe/mL per Hounsfield unit) was calculated from this phantom study as the quotient of known tube concentrations and their corresponding CT values. Retrospective analysis was performed of patients who had undergone DSDE imaging for renal stones. Thirty-seven patients with normal liver function were randomly selected (mean age, 52.5 years). The examinations were processed for iron concentration. Multiple regions of interest were analyzed, and iron concentration (mg Fe/mL) and distribution was reported. Results The mean conversion factor obtained from the phantom study was 0.15 mg Fe/mL per Hounsfield unit. Whole-liver mean iron concentrations yielded a range of 0.0 to 2.91 mg Fe/mL, with 94.6% (35/37) of the patients exhibiting mean concentrations below 1.0 mg Fe/mL. The most important finding was that iron concentration was not uniform and patients exhibited regionally high concentrations (36/37). These regions of higher concentration were observed to be dominant in the middle-to-upper part of the liver (75%), medially (72.2%), and anteriorly (83.3%). Conclusions Dual-source dual-energy CT can be used to assess the uniformity of iron distribution in healthy subjects. Applying similar techniques to unhealthy livers, future research may focus on the impact of hepatic iron content and distribution for noninvasive assessment in diseased subjects.
U.S. Diagnostic Reference Levels and Achievable Doses for 10 Adult CT Examinations
Kanal, Kalpana M. , Butler, Priscilla F. , Sengupta, Debapriya , Bhargavan, Mythreyi , Coombs, Laura P. , Morin, Richard L. , Bhargavan-Chatfield, Mythreyi

Radiology | February 21, 2017 | Volume: 284 | Issue: 1 | Pages: 120-133

10.1148/radiol.2017161911 Get It

In Vivo Comparison of Radiation Exposure of Dual-Energy CT Versus Low-Dose CT Versus Standard CT for Imaging Urinary Calculi
Jepperson, Maria A., Cernigliaro, Joseph G. , Morin, Richard L. , Haley, William E. , Thiel, David D. , Ibrahim, El‐Sayed H.

Journal of Endourology | July 24, 2014 | Volume: 29 | Issue: 2 | Pages: 141-146

10.1089/end.2014.0026 Get It

Purpose: Dual-energy computed tomography (DECT) is an emerging imaging modality with the unique capability of determining urinary stone composition. This study compares radiation exposure of DECT, standard single-energy CT (SECT), and low-dose renal stone protocol single-energy CT (LDSECT) for the evaluation of nephrolithiasis in a single in vivo patient cohort. Materials and Methods: Following institutional review board (IRB) approval, we retrospectively reviewed 200 consecutive DECT examinations performed on patients with suspected urolithiasis over a 6-month period. Of these, 35 patients had undergone examination with our LDSECT protocol, and 30 patients had undergone examination of the abdomen and pelvis with our SECT imaging protocol within 2 years of the DECT examination. The CT dose index volume (CTDI vol ) was used to compare radiation exposure between scans. Image quality was objectively evaluated by comparing image noise. Statistical evaluation was performed using a Student's t -test. Results: DECT performed at 80/140 kVp and 100/140 kVp did not produce a significant difference in radiation exposure compared with LDSECT ( p =0.09 and 0.18, respectively). DECT performed at 80/140 kVp and 100/140 kVp produced an average 40% and 31%, respectively, reduction in radiation exposure compared with SECT ( p <0.001). For patients imaged with the 100/140 kVp protocol, average values for images noise were higher in the LDSECT images compared with DECT images ( p <0.001) and there was no significant difference in image noise between DECT and SECT images in the same patient ( p =0.88). Patients imaged with the 80/140 kVp protocol had equivocal image noise compared with LDSECT images ( p =0.44), however, DECT images had greater noise compared with SECT images in the same patient ( p <0.001). Of the 75 patients included in the study, stone material was available for 16; DECT analysis correctly predicted stone composition in 15/16 patients (93%). Conclusion: DECT provides knowledge of stone composition in addition to the anatomic information provided by LDSECT/SECT without increasing patient radiation exposure and with minimal impact on image noise.
In vivo measurement of iron concentration using dual-source dual-energy CT
Weavers, Paul T., Jacobsen, Megan C. , Liu, Xin , Morin, Richard L. , McCollough, Cynthia H.

SPIE Proceedings | March 19, 2010 | Volume: 7622 | Issue: No issue available | Pages: 76223N

10.1117/12.845322 Get It

Patient doses in bone mineral densitometry
Huda, W, Morin, Richard L.

The British Journal of Radiology | July 15, 2009 | Volume: 69 | Issue: 821 | Pages: 422-425

10.1259/0007-1285-69-821-422 Get It

Abstract Procedures were developed to compute effective dose equivalent (HE) values for patients undergoing bone mineral densitometry (BMD) measurements such as dual energy X-ray absorptiometry (DEXA) and quantitative computed tomography (QCT). Representative values of HE were determined for patients undergoing each type of BMD procedure. Typical DEXA measurements are associated with an HE of about 2.5 μSv. For QCT, the values of HE are 300 μSv for single energy techniques and 1 mSv for dual energy techniques, respectively. By comparison, a single well collimated abdominal X-ray examination often taken in conjunction with DEXA studies results in an HE of about 100 μSv. BMD patient doses are at the lower end of the exposure range encountered in diagnostic radiology. As a result, radiation dose is not a primary factor in choosing the method for BMD determination.
Radiation Dose in Computed Tomography of the Heart
Morin, Richard L. , Gerber, Thomas C., McCollough, Cynthia H.

Circulation | February 18, 2003 | Volume: 107 | Issue: 6 | Pages: 917-922

10.1161/01.cir.0000048965.56529.c2 Get It