Back to Authors

Ibrahim, El‐Sayed H.

0000-0003-4292-4669

Mayo Clinic

WinnMed

Citations 4

The Influence of the analysis technique on estimating liver iron overload using magnetic resonance imaging T2* quantification
Khalifa, Ayman M. , Ibrahim, El‐Sayed H. , Eldaly, Ahmed Karam

2014 36th Annual International Conference of the IEEE Engineering in Medicine and Biology Society | November 12, 2014 | Volume: No volume available | Issue: No issue available | Pages: 4639-4642

10.1109/embc.2014.6944658 Get It

In Vivo Comparison of Radiation Exposure of Dual-Energy CT Versus Low-Dose CT Versus Standard CT for Imaging Urinary Calculi
Jepperson, Maria A., Cernigliaro, Joseph G. , Morin, Richard L. , Haley, William E. , Thiel, David D. , Ibrahim, El‐Sayed H.

Journal of Endourology | July 24, 2014 | Volume: 29 | Issue: 2 | Pages: 141-146

10.1089/end.2014.0026 Get It

Purpose: Dual-energy computed tomography (DECT) is an emerging imaging modality with the unique capability of determining urinary stone composition. This study compares radiation exposure of DECT, standard single-energy CT (SECT), and low-dose renal stone protocol single-energy CT (LDSECT) for the evaluation of nephrolithiasis in a single in vivo patient cohort. Materials and Methods: Following institutional review board (IRB) approval, we retrospectively reviewed 200 consecutive DECT examinations performed on patients with suspected urolithiasis over a 6-month period. Of these, 35 patients had undergone examination with our LDSECT protocol, and 30 patients had undergone examination of the abdomen and pelvis with our SECT imaging protocol within 2 years of the DECT examination. The CT dose index volume (CTDI vol ) was used to compare radiation exposure between scans. Image quality was objectively evaluated by comparing image noise. Statistical evaluation was performed using a Student's t -test. Results: DECT performed at 80/140 kVp and 100/140 kVp did not produce a significant difference in radiation exposure compared with LDSECT ( p =0.09 and 0.18, respectively). DECT performed at 80/140 kVp and 100/140 kVp produced an average 40% and 31%, respectively, reduction in radiation exposure compared with SECT ( p <0.001). For patients imaged with the 100/140 kVp protocol, average values for images noise were higher in the LDSECT images compared with DECT images ( p <0.001) and there was no significant difference in image noise between DECT and SECT images in the same patient ( p =0.88). Patients imaged with the 80/140 kVp protocol had equivocal image noise compared with LDSECT images ( p =0.44), however, DECT images had greater noise compared with SECT images in the same patient ( p <0.001). Of the 75 patients included in the study, stone material was available for 16; DECT analysis correctly predicted stone composition in 15/16 patients (93%). Conclusion: DECT provides knowledge of stone composition in addition to the anatomic information provided by LDSECT/SECT without increasing patient radiation exposure and with minimal impact on image noise.
Cardiac Mri As a Diagnostic Tool in Pulmonary Hypertension
Alassas, Khadija, Mergo, Patricia J. , Safford, Robert E. , Parikh, Pragnesh , Shapiro, Brian P. , Ibrahim, El‐Sayed H. , Burger, Charles D.

Future Cardiology | December 18, 2013 | Volume: 10 | Issue: 1 | Pages: 117-130

10.2217/fca.13.97 Get It

Advances of Cardiovascular MRI in Hypertrophic Cardiomyopathy
Blackshear, Joseph L., Mergo, Patricia J. , Parikh, Pragnesh , Batton, Kyle A., Shapiro, Brian P. , Kumar, Preetham, Kumar, Preetham , Ibrahim, El‐Sayed H.

Future Cardiology | September 11, 2013 | Volume: 9 | Issue: 5 | Pages: 697-709

10.2217/fca.13.58 Get It