Summary Modular, porous-coated, titanium segmental endoprostheses were implanted bilaterally in the femoral diaphysis of 7 adult mixed-breed dogs. Autogenous bone graft in particle form was placed around the implant and bone. In 1 limb, homologous fibrin adhesive was mixed with the graft in situ before soft tissue closure. The contralateral limb was grafted in identical manner, but without fibrin adhesive, and served as a control. Radiography was performed immediately after surgery and 1, 2, 3, 4, 6, 8, 10, and 12 weeks later to assess callus area and bone remodeling. At 12 weeks, dogs were euthanatized and bone/implant fixation strength was tested under torsion and compared with values for 6 in vitro controls. Histomorphometric and microradiographic analyses of transverse sections of the distal portion of the implanted femurs were performed. Radiographic callus area was significantly (P < 0.05) smaller in the femurs grafted with fibrin adhesive, compared with the contralateral control. New bone formation (21.4 ± 1.8% vs 19.2 ± 2.4%), unlabeled bone (64.8 ± 3.0% vs 67.9 ± 4.2%), porosity (13.9 ± 0.7% vs 12.9 ± 0.8%), and bone ingrowth into the porous coating (10.3 ± 0.9% vs 10.0 ± 1.2%) were not significantly different between fibrin- and nonfibrin-grafted implants, respectively. There were no significant differences in torsional strength of implant fixation between the fibrin- and nonfibrin-grafted femurs or between the in vivo implanted femurs and the in vitro controls. These data indicate that fibrin adhesive may have been advantageous in maintaining apposition of bone graft adjacent to the endoprosthesis, but it probably did not have an enhancing effect on extracortical bone bridging or ingrowth over a porous-coated segmental bone replacement endoprosthesis.
Effect of titanium endoprostheses on bone mineral density measurements, using quantitative computed tomography
Summary Quantitative computed tomography has been used extensively to measure bone mineral density; particularly in the vertebral column and in the proximal portion of the femur in human beings with osteoporosis. Other potential applications of this technique include evaluation of bone adjacent to metallic endoprostheses and evaluation of fractures as they heal. Unfortunately, metal causes severe image degradation, principally seen as starburst streaking. One method used to decrease these artifacts is by imaging less-attenuating materials, such as titanium alloy. Titanium decreases image degradation sufficiently to allow accurate determination of the geometric properties of cadaveric bone. In our study, the effect of a titanium segmental endoprosthesis on bone mineral density measurement was determined by use of bone specimens from dogs and calibration standards. Titanium decreased the bone mineral density of calibration solutions from 6.8 (500 mg/cm3) to 17.7% (250 mg/cm3), and increased bone mineral density of cortical bone by 5.3%. Titanium did not affect the repeatability of these scans, indicating that the error caused by titanium was systematic and can be corrected. Our data were suggestive that quantitative computed tomography can be used to measure bone mineral density of cortical bone adjacent to titanium endoprostheses, with a predictable increase in density measurement.
Multiplanar quantitative computed tomography for bone mineral analysis in dogs
Summary The purpose of this study was to determine the precision and accuracy of quantitative computed tomography bone mineral analysis in dogs in coronally reconstructed images. Nonhomogeneous tissues, such as bones with fractures or deformities, may be better analyzed if multiplanar reconstruction of the transaxial data could be performed without degradation of information. Our analysis demonstrated that coronal reconstruction of quantitative-computed tomography data was precise (1.2 to 4.7%) and accurate (1.3 to 7.5%) in vitro. The technique displays high-quality images, which can be analyzed at any location within the volume scanned. Quantitative computed tomography of canine osteotomy healing in vivo accurately determined bone mineral density of selected regions of interest. Bone mineral density correlated highly with calcium content of the tissue (R2 = 0.76, P < 0.0001).
Mechanical and morphometric analysis of the third carpal bone of Thoroughbreds
SUMMARY The third carpal bone (C 3 ) was collected from both forelimbs of 27 Thoroughbreds. On the basis of age, training, and history, specimens were assigned to 1 of 5 groups: yearling, untrained horses (group 1, n = 4); 2- to 3-year-old, untrained horses (group 2, n = 7); trained 2-year-old horses (group 3, n = 6); trained 3-year-old horses (group 4, n = 6); and 3-year-old, trained horses with carpal pathologic features (group 5, n = 4). A transverse section of subchondral bone 5-mm thick was cut in a precise fashion 10 mm below the proximal articular surface of all specimens. After high-detail radiography was done, indentation testing was performed on the proximal surface of the section at points 5 mm apart. The stiffness of the subchondral cancellous bone was determined from the slope of the load vs displacement curve. Topographic plots of stiffness measurements were compared with radiographs of each specimen. Point determinations were averaged to derive measures for the radial and intermediate facets, and for regions 5, 10, 15, and 20 mm from the dorsal margin of C 3 . Area fraction (1-p; p = porosity) was measured for the radial and intermediate facets, using an automated image analysis system. Significant ( P < 0.05) increases in stiffness and area fraction were found in the C 3 from trained horses (groups 3 to 5), compared with untrained horses (groups 1 to 2). Stiffness and area fraction of the radial facet of pathologic C 3 were significantly higher than the same variables measured in C 3 from any other group. A typical profile of regional subchondral stiffness was identified in C 3 from normal horses, with maximal stiffness measured 10 mm from the dorsal articular margin. A different pattern was found in pathologic C 3 , with significantly greater stiffness 15 and 20 mm from the dorsal articular margin when compared with normal horses. A highly significant ( P < 0.0001) direct linear correlation between stiffness and area fraction at the radial facet was found. Topographic and radiographic analysis demonstrated good correlation between stiffness and radiographic density of the bone sections. The observed patterns of normal and pathologic C 3 were contrasted. In particular, a large gradient in subchondral stiffness was identified in pathologic C 3 at the dorsomedial aspect of the bone.