AAPM Task Group 334: A guidance document to using radiotherapy immobilization devices and accessories in an MR environment
Hobson, Maritza A. , Hu, Yanle , Glide‐Hurst, Carri , Jackson, Paul D., Jang, Sunyoung, Narayanan, Sreeram, Park, Justin C., Steffen, John J., Zhou, Yong , Caldwell, Barrett S. , Cohen, Gil’ad N. , Huang, Long , Jang, Sunyoung, Langner, Ulrich W. , Lee, Hannah J. , Levesque, Ives R. , Steffen, John, Wu, Qiuwen , Zhou, Yong

Medical Physics | April 22, 2024 | Volume: 51 | Issue: 6 | Pages: 3822-3849

10.1002/mp.17061 Get It

AbstractUse of magnetic resonance (MR) imaging in radiation therapy has increased substantially in recent years as more radiotherapy centers are having MR simulators installed, requesting more time on clinical diagnostic MR systems, or even treating with combination MR linear accelerator (MR‐linac) systems. With this increased use, to ensure the most accurate integration of images into radiotherapy (RT), RT immobilization devices and accessories must be able to be used safely in the MR environment and produce minimal perturbations. The determination of the safety profile and considerations often falls to the medical physicist or other support staff members who at a minimum should be a Level 2 personnel as per the ACR. The purpose of this guidance document will be to help guide the user in making determinations on MR Safety labeling (i.e., MR Safe, Conditional, or Unsafe) including standard testing, and verification of image quality, when using RT immobilization devices and accessories in an MR environment.
Findings of the AAPM Ad Hoc committee on magnetic resonance imaging in radiation therapy: Unmet needs, opportunities, and recommendations
McGee, Kiaran P. , Tyagi, Neelam , Bayouth, John E. , Fallone, B. G. , Glide‐Hurst, Carri , Goerner, F, Green, Olga L., Kim, Taeho , Paulson, E.S. , Yanasak, N. E. , Goodwin, James, Jordan, David W. , Hugo, Geoffrey D., Balter, James M. , Kanal, Kalpana M. , Hazle, John D. , Pelc, Norbert J. , Cao, Minsong , Jackson, Edward F. , Dieterich, Sonja , Bernstein, Matt A.

Medical Physics | July 7, 2021 | Volume: 48 | Issue: 8 | Pages: 4523-4531

10.1002/mp.14996 Get It

The past decade has seen the increasing integration of magnetic resonance (MR) imaging into radiation therapy (RT). This growth can be contributed to multiple factors, including hardware and software advances that have allowed the acquisition of high‐resolution volumetric data of RT patients in their treatment position (also known as MR simulation) and the development of methods to image and quantify tissue function and response to therapy. More recently, the advent of MR‐guided radiation therapy (MRgRT) ‐ achieved through the integration of MR imaging systems and linear accelerators ‐ has further accelerated this trend. As MR imaging in RT techniques and technologies, such as MRgRT, gain regulatory approval worldwide, these systems will begin to propagate beyond tertiary care academic medical centers and into more community‐based health systems and hospitals, creating new opportunities to provide advanced treatment options to a broader patient population. Accompanying these opportunities are unique challenges related to their adaptation, adoption, and use including modification of hardware and software to meet the unique and distinct demands of MR imaging in RT, the need for standardization of imaging techniques and protocols, education of the broader RT community (particularly in regards to MR safety) as well as the need to continue and support research, and development in this space. In response to this, an ad hoc committee of the American Association of Physicists in Medicine (AAPM) was formed to identify the unmet needs, roadblocks, and opportunities within this space. The purpose of this document is to report on the major findings and recommendations identified. Importantly, the provided recommendations represent the consensus opinions of the committee’s membership, which were submitted in the committee's report to the AAPM Board of Directors. In addition, AAPM ad hoc committee reports differ from AAPM task group reports in that ad hoc committee reports are neither reviewed nor ultimately approved by the committee’s parent groups, including at the council and executive committee level. Thus, the recommendations given in this summary should not be construed as being endorsed by or official recommendations from the AAPM.
Task group 284 report: magnetic resonance imaging simulation in radiotherapy: considerations for clinical implementation, optimization, and quality assurance
Glide‐Hurst, Carri , Paulson, E.S. , McGee, Kiaran P. , Tyagi, Neelam , Hu, Yanle , Balter, James M. , Bayouth, John E. , McGee, Kiaran

Medical Physics | January 2, 2021 | Volume: 48 | Issue: 7 | Pages: No page available

10.1002/mp.14695 Get It

The use of dedicated magnetic resonance simulation (MR‐SIM) platforms in Radiation Oncology has expanded rapidly, introducing new equipment and functionality with the overall goal of improving the accuracy of radiation treatment planning. However, this emerging technology presents a new set of challenges that need to be addressed for safe and effective MR‐SIM implementation. The major objectives of this report are to provide recommendations for commercially available MR simulators, including initial equipment selection, siting, acceptance testing, quality assurance, optimization of dedicated radiation therapy specific MR‐SIM workflows, patient‐specific considerations, safety, and staffing. Major contributions include guidance on motion and distortion management as well as MRI coil configurations to accommodate patients immobilized in the treatment position. Examples of optimized protocols and checklists for QA programs are provided. While the recommendations provided here are minimum requirements, emerging areas and unmet needs are also highlighted for future development.