Back to Authors

Cao, Minsong

0000-0003-4705-6629

Mayo Clinic

University of California, Los Angeles

Citations 3

The Use of Magnetic Resonance Imaging in Radiation Therapy Treatment Simulation and Planning
McGee, Kiaran P. , Yu, Victoria , Witte, Robert J. , Kishan, Amar U. , Valle, Luca , Wiesinger, Florian , De‐Colle, Chiara , Cao, Yue , Breen, William G. , Traughber, Bryan J, McGee, Kiaran , Cao, Minsong , Das, Indra J. , Traughber, Bryan

Journal of Magnetic Resonance Imaging | January 24, 2024 | Volume: No volume available | Issue: No issue available | Pages: No page available

10.1002/jmri.29246 Get It

Ever since its introduction as a diagnostic imaging tool the potential of magnetic resonance imaging (MRI) in radiation therapy (RT) treatment simulation and planning has been recognized. Recent technical advances have addressed many of the impediments to use of this technology and as a result have resulted in rapid and growing adoption of MRI in RT. The purpose of this article is to provide a broad review of the multiple uses of MR in the RT treatment simulation and planning process, identify several of the most used clinical scenarios in which MR is integral to the simulation and planning process, highlight existing limitations and provide multiple unmet needs thereby highlighting opportunities for the diagnostic MR imaging community to contribute and collaborate with our oncology colleagues.Evidence Level5Technical EfficacyStage 5
A simulated comparison of lung tumor target verification using stereoscopic tomosynthesis or radiography
Hsieh, Scott S. , Ng, Lydia W., Lee, Percy , Cao, Minsong

Medical Physics | March 23, 2022 | Volume: 49 | Issue: 5 | Pages: 3041-3052

10.1002/mp.15634 Get It

AbstractPurposeMobile lung tumors are increasingly being treated with ablative radiotherapy, for which precise motion management is essential. In‐room stereoscopic radiography systems are able to guide ablative radiotherapy for stationary cranial lesions but not optimally for lung tumors unless fiducial markers are inserted. We propose augmenting stereoscopic radiographic systems with multiple small x‐ray sources to provide the capability of imaging with stereoscopic, single frame tomosynthesis.MethodsIn single frame tomosynthesis, nine x‐ray sources are placed in a 3 × 3 configuration and energized simultaneously. The beams from these sources are collimated so that they converge on the tumor and then diverge to illuminate nine non‐overlapping sectors on the detector. These nine sector images are averaged together and filtered to create the tomosynthesis effect. Single frame tomosynthesis is intended to be an alternative imaging mode for existing stereoscopic systems with a field of view that is three times smaller and a temporal resolution equal to the frame rate of the detector. We simulated stereoscopic tomosynthesis and radiography using Monte Carlo techniques on 60 patients with early‐stage lung cancer from the NSCLC‐Radiomics dataset. Two board‐certified radiation oncologists reviewed these simulated images and rated them on a 4‐point scale (1: tumor not visible; 2: tumor visible but inadequate for motion management; 3: tumor visible and adequate for motion management; 4: tumor visibility excellent). Each tumor was independently presented four times (two viewing angles from radiography and two viewing angles from tomosynthesis) in a blinded fashion over two reading sessions.ResultsThe fraction of tumors that were rated as adequate or excellent for motion management (scores 3 or 4) from at least one viewing angle was 53% using radiography and 90% using tomosynthesis. From both viewing angles, the corresponding fractions were 7% for radiography and 48% for tomosynthesis. Readers agreed exactly on 62% of images and within 1 point on 98% of images. The acquisition technique was estimated to be 75 mAs at 120 kVp per treatment fraction assuming one verification image per breath, approximately one order of magnitude less than a standard dose cone beam CT.Conclusions Stereoscopic tomosynthesis may provide a noninvasive, low dose, intrafraction motion verification technique for lung tumors treated by ablative radiotherapy. The system architecture is compatible with real‐time video capture at 30 frames per second. Simulations suggest that most, but not all, lung tumors can be adequately visualized from at least one viewing angle.
Findings of the AAPM Ad Hoc committee on magnetic resonance imaging in radiation therapy: Unmet needs, opportunities, and recommendations
McGee, Kiaran P. , Tyagi, Neelam , Bayouth, John E. , Fallone, B. G. , Glide‐Hurst, Carri , Goerner, F, Green, Olga L., Kim, Taeho , Paulson, E.S. , Yanasak, N. E. , Goodwin, James, Jordan, David W. , Hugo, Geoffrey D., Balter, James M. , Kanal, Kalpana M. , Hazle, John D. , Pelc, Norbert J. , Cao, Minsong , Jackson, Edward F. , Dieterich, Sonja , Bernstein, Matt A.

Medical Physics | July 7, 2021 | Volume: 48 | Issue: 8 | Pages: 4523-4531

10.1002/mp.14996 Get It

The past decade has seen the increasing integration of magnetic resonance (MR) imaging into radiation therapy (RT). This growth can be contributed to multiple factors, including hardware and software advances that have allowed the acquisition of high‐resolution volumetric data of RT patients in their treatment position (also known as MR simulation) and the development of methods to image and quantify tissue function and response to therapy. More recently, the advent of MR‐guided radiation therapy (MRgRT) ‐ achieved through the integration of MR imaging systems and linear accelerators ‐ has further accelerated this trend. As MR imaging in RT techniques and technologies, such as MRgRT, gain regulatory approval worldwide, these systems will begin to propagate beyond tertiary care academic medical centers and into more community‐based health systems and hospitals, creating new opportunities to provide advanced treatment options to a broader patient population. Accompanying these opportunities are unique challenges related to their adaptation, adoption, and use including modification of hardware and software to meet the unique and distinct demands of MR imaging in RT, the need for standardization of imaging techniques and protocols, education of the broader RT community (particularly in regards to MR safety) as well as the need to continue and support research, and development in this space. In response to this, an ad hoc committee of the American Association of Physicists in Medicine (AAPM) was formed to identify the unmet needs, roadblocks, and opportunities within this space. The purpose of this document is to report on the major findings and recommendations identified. Importantly, the provided recommendations represent the consensus opinions of the committee’s membership, which were submitted in the committee's report to the AAPM Board of Directors. In addition, AAPM ad hoc committee reports differ from AAPM task group reports in that ad hoc committee reports are neither reviewed nor ultimately approved by the committee’s parent groups, including at the council and executive committee level. Thus, the recommendations given in this summary should not be construed as being endorsed by or official recommendations from the AAPM.