Back to Authors

Yuan, Chun

https://orcid.org/0000-0002-6154-5106

Mayo Clinic

University of Washington

Citations 6

Magnetic Resonance Imaging of Intraplaque Hemorrhage and Plaque Lipid Content With Continued Lipid-Lowering Therapy: Results of a Magnetic Resonance Imaging Substudy in AIM-HIGH
Zhao, Xue-Qiao , Hippe, Daniel S. , Isquith, Daniel , Cantón, Gádor , Yamada, Kiyofumi , Balu, Niranjan , Crouse, John R., Anderson, Todd J. , Huston, John , O’Brien, Kevin D. , Yuan, Chun , Investigators, for the AIM-HIGH Carotid MRI Substudy, Huston, John , Hippe, Daniel S , Yamada, Kiyofumi , O'Brien, Kevin D , Hatsukami, Thomas S , Yuan, Chun , Sun, Jie , Investigators, for the AIM-HIGH Carotid MRI Substudy

Circulation: Cardiovascular Imaging | November 15, 2022 | Volume: 15 | Issue: 11 | Pages: No page available

10.1161/circimaging.122.014229 Get It

Background: Intraplaque hemorrhage (IPH) is associated with plaque progression and ischemic events, and plaque lipid content (% lipid core) predicts the residual atherosclerotic cardiovascular disease risk. This study examined the impact of IPH on lipid content change in the setting of intensive lipid-lowering therapy. Methods: In total, 214 AIM-HIGH (Atherothrombosis Intervention in Metabolic Syndrome with Low High-Density Lipoprotein/High Triglycerides: Impact on Global Health Outcomes) participants with clinically established ASCVD and low high-density lipoprotein cholesterol received cartoid MRI at baseline and 2 years to assess changes in carotid morphology and composition. Patients were randomized to extended-release niacin or placebo, and all received simvastatin with optional ezetimibe as necessary to lower low-density lipoprotein cholesterol to 40 to 80 mg/dL. Changes in lipid content and carotid morphology were tested using the Wilcoxon signed-rank test. Differences between subjects with and without IPH and between subjects assigned extended-release niacin or placebo were tested using the Wilcoxon rank-sum test. Linear regression was used to test the association of IPH and lipid content changes after adjusting for clinical risk factors. Results: Among 156 patients (61±9 years; 81% men) with complete MRI, prior statin use: <1 year, 26%; 1 to 5 years, 37%; >5 years, 37%. Triglycerides and ApoB decreased significantly, whereas high-density lipoprotein cholesterol and ApoA1 increased significantly over time. Plaque lipid content was significantly reduced (−0.5±2.4 %/year, P = 0.017) without a significant difference between the 2 treatment groups. However, the lipid content increased in plaques with IPH but regressed in plaques without IPH (1.2±2.5 %/year versus −1.0±2.2, P = 0.006). Additionally, IPH was associated with a decrease in lumen area (−0.4±0.9 mm2/year versus 0.3±1.4, P = 0.033). IPH remained significantly associated with increase in lipid content in multivariable analysis (54.4%, 95% CI: 26.8, 88.0, P < 0.001). Conclusions: Carotid plaques under continued intensive lipid-lowering therapy moved toward stabilization. However, plaques with IPH showed greater increases in lipid content and greater decreases in lumen area than plaques without IPH. Registration: URL: https://www.clinicaltrials.gov ; Unique identifier: NCT01178320.
Abstract 16514: Magnetic Resonance Imaging-Detected Carotid Plaque Characteristics Predict Systemic Cardiovascular Outcomes in Patients With Clinically Established Atherosclerosis in the AIH-HIGH Study
Zhao, Xue‐Qiao, Balu, Niranjan , Neradilek, Moni B. , Isquith, Daniel , Cantón, Gádor , Crouse, John R., Anderson, Todd J. , Polissar, Nayak L. , Yuan, Chun , Sun, Jie , Zhao, Xue-Qiao, Yamada, Kiyofumi , Huston, John , O’Brien, Kevin D. , Hippe, Daniel S. , Hatsukami, Thomas S

Circulation | July 3, 2021 | Volume: 130 | Issue: suppl_2 | Pages: No page available

10.1161/circ.130.suppl_2.16514 Get It

Background: Although vulnerable plaques are considered the pathological substrate for acute cardiovascular events, the pursuit of imaging surrogate markers for systemic atherothrombotic risk is currently focused on plaque burden. The prognostic value of vulnerable plaque characteristics as novel markers for systemic cardiovascular outcomes remains elusive. Advances in magnetic resonance imaging (MRI) have enabled characterization of the vulnerable carotid plaque. In a prospective study, we tested whether MRI-detected carotid plaque characteristics predict subsequent cardiovascular events. Methods: As part of an event-driven clinical trial, subjects with clinically established atherosclerotic disease were recruited. A multi-sequence protocol was used to measure the volumes of calcification and necrotic core (NC), and to identify the presence of intraplaque hemorrhage (IPH) and thin/ruptured fibrous cap (FC) using published criteria. The primary endpoint included fatal and non-fatal myocardial infarction or ischemic stroke, hospitalization for acute coronary syndrome, and symptom-driven revascularization. Cox regression analysis was used to present results as hazard ratio (HR) with 95% confidence interval (CI). Results: Of 232 subjects recruited, 214 (92.2%) with diagnostic image quality constituted the study population (mean age: 61±9 years; male: 82%; statin use: 94%). Calcification, NC, IPH, and thin/ruptured FC were detected in 48%, 52%, 8% and 14% of subjects, respectively. During a median follow-up of 35.1 months, 18 (8.4%) subjects reached the primary endpoint. MRI-detected plaque characteristics associated with the primary endpoint included larger NC (HR per 1 standard deviation increase in volume [1-SD]: 1.43 [1.16, 1.75], p<0.001), thin/ruptured FC (HR: 4.31 [1.67, 11.12], p=0.003), and marginally IPH (HR: 3.00 [0.99, 9.13], p=0.053). Although calcium deposition is traditionally pursued as a marker for atherosclerosis, subjects with larger calcification (HR per 1-SD: 0.60 [0.26, 1.41], p=0.20) did not show increased risk. Conclusions: Vulnerable plaque characteristics are prevalent in carotid arteries of patients with established atherosclerosis and are predictive of systemic cardiovascular outcomes.
A standard system phantom for magnetic resonance imaging
Stupic, Karl F. , Ainslie, Maureen, Boss, Michael A. , Charles, Cecil, Dienstfrey, Andrew , Evelhoch, Jeffrey L., Finn, Paul, Gimbutas, Zydrunas , Gunter, Jeffrey L. , Hill, David , Karaulanov, Todor , Liu, Guoying , Martin, Michele N. , Prasad, Pottumarthi V. , Rentz, Nikki S., Yuan, Chun , Keenan, Kathryn E , Yuan, Chun , Russek, Stephen E , Boss, Michael A , Jack, Clifford R. , Jackson, Edward F. , Keenan, Kathryn E. , Russek, Stephen E.

Magnetic Resonance in Medicine | April 13, 2021 | Volume: 86 | Issue: 3 | Pages: 1194-1211

10.1002/mrm.28779 Get It

Purpose A standard MRI system phantom has been designed and fabricated to assess scanner performance, stability, comparability and assess the accuracy of quantitative relaxation time imaging. The phantom is unique in having traceability to the International System of Units, a high level of precision, and monitoring by a national metrology institute. Here, we describe the phantom design, construction, imaging protocols, and measurement of geometric distortion, resolution, slice profile, signal‐to‐noise ratio (SNR), proton‐spin relaxation times, image uniformity and proton density. Methods The system phantom, designed by the International Society of Magnetic Resonance in Medicine ad hoc committee on Standards for Quantitative MR, is a 200 mm spherical structure that contains a 57‐element fiducial array; two relaxation time arrays; a proton density/SNR array; resolution and slice‐profile insets. Standard imaging protocols are presented, which provide rapid assessment of geometric distortion, image uniformity, T 1 and T 2 mapping, image resolution, slice profile, and SNR. Results Fiducial array analysis gives assessment of intrinsic geometric distortions, which can vary considerably between scanners and correction techniques. This analysis also measures scanner/coil image uniformity, spatial calibration accuracy, and local volume distortion. An advanced resolution analysis gives both scanner and protocol contributions. SNR analysis gives both temporal and spatial contributions. Conclusions A standard system phantom is useful for characterization of scanner performance, monitoring a scanner over time, and to compare different scanners. This type of calibration structure is useful for quality assurance, benchmarking quantitative MRI protocols, and to transition MRI from a qualitative imaging technique to a precise metrology with documented accuracy and uncertainty.
Vascular contributions to cognitive impairment and dementia (VCID): A report from the 2018 National Heart, Lung, and Blood Institute and National Institute of Neurological Disorders and Stroke Workshop
McKee, Ann C. , Snyder, Heather M. , Greenberg, Steven M. , Yaffe, Kristine , Schaffer, Chris B. , Yuan, Chun , Hughes, Timothy M. , Williamson, Jeff D. , González, Héctor M. , Wellington, Cheryl L. , Katušić, Zvonimir S. , Stoeckel, Luke E. , Corriveau, Roderick A. , Fine, Lawrence J., Galis, Zorina S. , Reis, Jared P. , Wright, Jacqueline D. , Chen, Jue , Galis, Zorina S , Gonzalez, Hector M , Zloković, Berislav V. , Gottesman, Rebecca F. , Bernstein, Kenneth E. , Seshadri, Sudha , Daemen, Mat J.A.P. , Schneider, Julie A. , Koenig, James I. , Chen, Jue

Alzheimer's & Dementia | October 8, 2020 | Volume: 16 | Issue: 12 | Pages: 1714-1733

10.1002/alz.12157 Get It

Abstract Vascular contributions to cognitive impairment and dementia (VCID) are characterized by the aging neurovascular unit being confronted with and failing to cope with biological insults due to systemic and cerebral vascular disease, proteinopathy including Alzheimer's biology, metabolic disease, or immune response, resulting in cognitive decline. This report summarizes the discussion and recommendations from a working group convened by the National Heart, Lung, and Blood Institute and the National Institute of Neurological Disorders and Stroke to evaluate the state of the field in VCID research, identify research priorities, and foster collaborations. As discussed in this report, advances in understanding the biological mechanisms of VCID across the wide spectrum of pathologies, chronic systemic comorbidities, and other risk factors may lead to potential prevention and new treatment strategies to decrease the burden of dementia. Better understanding of the social determinants of health that affect risks for both vascular disease and VCID could provide insight into strategies to reduce racial and ethnic disparities in VCID.
Vascular dysfunction—The disregarded partner of Alzheimer's disease
Sweeney, Melanie D. , Montagne, Axel , Nation, Daniel A. , Schneider, Lon S. , Chui, Helena C., Harrington, Michael G. , Pa, Judy , Law, Meng , Wang, Danny J.J. , Jacobs, Russell E. , Doubal, Fergus , Ramirez, Joel , Dichgans, Martin , Love, Seth , Bath, Philip M. , Markus, Hugh S. , Salman, Rustam Al‐Shahi , Kalaria, Rajesh N., Werring, David J. , Moskowitz, Michael A., Katušić, Zvonimir S. , Lazarov, Orly , Rehman, Jalees , Wellington, Cheryl L. , González, Héctor M. , Yuan, Chun , Lockhart, Samuel N. , Hughes, Timothy M. , Chen, Christopher , Sachdev, Perminder S. , O’Brien, John T. , Pantoni, Leonardo , Gustafson, Deborah , Biessels, Geert Jan , Wallin, Anders , Wong, Adrian , Passmore, Peter , Barkof, Frederick, Muller, Majon , Román, Gustavo C. , Hamel, Édith , Seshadri, Sudha , Buchem, Mark A. van , Arvanitakis, Zoe , Drewes, Lester R. , Hachinski, Vladimir , Wardlaw, Joanna M. , Kalaria, Raj N. , Dichgans, Martin , O'Brien, John Tiernan , Wardlaw, Joanna Marguerite , Seshadri, Sudha , Sachdev, Perminder S , Sagare, Abhay P. , Chui, Helena C. , Black, Sandra E. , Nedergaard, Maiken , Benveniste, Helene , Iadecola, Costantino , Allan, Stuart McRae , Quinn, Terence J , Carare, Roxana Octavia , Touyz, Rhian M. , Williams, Steven , Lutz, Sarah E. , Minshall, Richard D. , Davis, Thomas P. , Gonzalez, Hector M , Skoog, Ingmar , Biessels, Geert Jan , Smith, Eric Edward , Mok, Vincent , Breteler, Monique M.B. , Gottesman, Rebecca F. , Schneider, Julie A. , Finch, Caleb E. , Toga, Arthur W. , Zloković, Berislav V. , Al-Shahi Salman, Rustam , Werring, David John , Wang, Danny J J

Alzheimer's & Dementia | January 11, 2019 | Volume: 15 | Issue: 1 | Pages: 158-167

10.1016/j.jalz.2018.07.222 Get It

Abstract Increasing evidence recognizes Alzheimer's disease (AD) as a multifactorial and heterogeneous disease with multiple contributors to its pathophysiology, including vascular dysfunction. The recently updated AD Research Framework put forth by the National Institute on Aging–Alzheimer's Association describes a biomarker‐based pathologic definition of AD focused on amyloid, tau, and neuronal injury. In response to this article, here we first discussed evidence that vascular dysfunction is an important early event in AD pathophysiology. Next, we examined various imaging sequences that could be easily implemented to evaluate different types of vascular dysfunction associated with, and/or contributing to, AD pathophysiology, including changes in blood‐brain barrier integrity and cerebral blood flow. Vascular imaging biomarkers of small vessel disease of the brain, which is responsible for >50% of dementia worldwide, including AD, are already established, well characterized, and easy to recognize. We suggest that these vascular biomarkers should be incorporated into the AD Research Framework to gain a better understanding of AD pathophysiology and aid in treatment efforts.
Quantitative magnetic resonance imaging phantoms: A review and the need for a system phantom
Keenan, Kathryn E. , Ainslie, Maureen, Barker, Alex J. , Boss, Michael A. , Cecil, Kim M. , Charles, Cecil, Chenevert, Thomas L. , Clarke, L., Evelhoch, Jeffrey L., Finn, Paul, Gembris, Daniel, Gunter, Jeffrey L. , Hill, David , Jack, Clifford R. , Liu, Guoying , Sharma, Samir D. , Steckner, Michael , Stupic, Karl F. , Trzasko, Joshua D. , Yuan, Chun , Zheng, Jie , Jack, Clifford R , Barker, Alex J , Keenan, Kathryn E , Boss, Michael A , Jackson, Edward F. , Russek, Stephen E.

Magnetic Resonance in Medicine | October 30, 2017 | Volume: 79 | Issue: 1 | Pages: 48-61

10.1002/mrm.26982 Get It

The MRI community is using quantitative mapping techniques to complement qualitative imaging. For quantitative imaging to reach its full potential, it is necessary to analyze measurements across systems and longitudinally. Clinical use of quantitative imaging can be facilitated through adoption and use of a standard system phantom, a calibration/standard reference object, to assess the performance of an MRI machine. The International Society of Magnetic Resonance in Medicine AdHoc Committee on Standards for Quantitative Magnetic Resonance was established in February 2007 to facilitate the expansion of MRI as a mainstream modality for multi‐institutional measurements, including, among other things, multicenter trials. The goal of the Standards for Quantitative Magnetic Resonance committee was to provide a framework to ensure that quantitative measures derived from MR data are comparable over time, between subjects, between sites, and between vendors. This paper, written by members of the Standards for Quantitative Magnetic Resonance committee, reviews standardization attempts and then details the need, requirements, and implementation plan for a standard system phantom for quantitative MRI. In addition, application‐specific phantoms and implementation of quantitative MRI are reviewed. Magn Reson Med 79:48–61, 2018. © 2017 International Society for Magnetic Resonance in Medicine.