Abstract Objective . The use of Feraheme (ferumoxytol) as a contrast agent in MR-guided focused ultrasound (MRgFUS) tumor ablations could enhance treatment safety and efficacy by improving vascular visualization through strong T1 and T2 shortening effects. However, Feraheme impact on MR thermometry and tissue heating is unclear. This study evaluates the feasibility of incorporating Feraheme into MRgFUS by assessing its impact on MR imaging contrast, MR thermometry, and thermal response in tissue-mimicking phantoms. Approach . Tissue-mimicking phantoms with 0 (baseline), 0.25, and 0.5 mM Feraheme concentrations were prepared using a validated recipe. Acoustic attenuation was measured with a commercial diagnostic ultrasound scanner. MR imaging at 1.5 T was performed to assess gradient-recalled-echo (GRE)-based thermometry signal-to-noise-ratio (SNR), relaxation rates, and relaxivities. MRgFUS system integrated with 1.5 T MRI was used to perform multiple sonications in the phantoms. Temperature elevations and focal heating areas were quantified from proton resonance frequency (PRF) shift thermometry. Experiments were repeated three times over the period of eight-weeks. Separately, temperature-dependent nuclear magnetic resonance (NMR) spectroscopy was performed at 3.0 T in saline-diluted Feraheme phantoms (0, 0.25, 0.5, and 1.0 mM) to assess the influence of Feraheme concentration on PRF coefficients used in MR thermometry. Main results . Phantoms showed nuclear relaxation times ( T 1: 1178.1 ± 77.8, T 2: 103.21 ± 2.45 ms) and attenuation coefficients (0.34–0.36 dB cm −1 MHz −1 ) within expected biological tissue ranges. Relaxivities demonstrated a strong linear dependence on Feraheme concentration ( r 1: 17.5 ± 0.2, r 2: 209.2 ± 2.6 s −1 mM −1 ). Relative to baseline (0 mM) phantom, the SNR of GRE-based thermometry increased by 12.6% at 0.25 mM and decreased by 27.1% at 0.5 mM. Sonications in Feraheme-containing phantoms resulted in statistically higher temperature elevations ( p < 0.001 ) although no statistically significant difference was observed between 0.25 and 0.5 mM. All NMR measurements demonstrated stable, linear PRF temperature dependence ( R 2 = 0.996–0.999), with PRF coefficients (between −0.0074 and −0.0082 ppm °C −1 ). The resulting thermometry bias was small and predictable (+0.67 and +1.73 per 20 °C at 3.0 T for 0.25 and 0.5 mM). Significance . These findings demonstrate that MR thermometry remains feasible at moderate Feraheme concentrations and support its potential use to enhance visualization of critical vasculature near targeted tissues during MRgFUS.
Abstract Osteoarthritis of the knee is a common cause of pain, functional disability, and reduced quality of life in the elderly. Despite its prevalence, there are limited currently available noninvasive treatment options. MRI-guided focused ultrasound (MRgFUS) is a noninvasive thermal ablation method which is used in a spectrum of musculoskeletal conditions. It is FDA approved for the treatment of painful bone metastases and osteoid osteoma, and has been considered for the treatment of other painful conditions such as osteoarthritis. The purpose of this case report is to describe the use of MRgFUS for the treatment of osteoarthritic knee pain in a 72-year-old male. The patient led an active lifestyle, however suffered significant limitations due to lateral knee pain with jogging and walking down the stairs. MRgFUS ablation treatment was performed to the lateral knee, targeting the periosteum in the patients’ area of pain. Following treatment, he experienced considerable reduction in his activity limiting symptoms with a duration of at least 6 months. Similar pain reduction was observed in two small series of MRgFUS treatment of knee pain from Japan. It is important for radiologists to be aware of MRgFUS as an innovative ablation modality. MRgFUS appears promising as a safe, non-invasive treatment option for temporary relief of knee pain. This may be particularly valuable for patients who are unwilling or unable to undergo total knee arthroplasty.
Use of ultrasound gel to mitigate risks of skin burns from non-actively cooled mic rowave applicators
The purpose of this study is to investigate the potential of using ultrasound gel to mitigate the risks of skin burn at the insertion site during microwave ablation (MWA) using non-actively cooled applicators. Ex vivo experiments in porcine tissue were conducted using two identical MWA systems. Five MWA scenarios were tested at different applicator insertion depths with an ultrasound gel layer applied at the applicator insertion sites: 8 cm insertion depth with and without 4 cm thick gel, 10 cm insertion depth with and without 2 cm thick gel, and 12 cm insertion depth without gel (reference). In all experiments, temperature elevations at the applicator insertion site on the tissue surface were recorded using thermal sensors in all experiments during 10-min MWA. The application of ultrasound gel and increasing applicator insertion depths resulted in measurable reductions in temperature elevations at the applicator insertion sites. For an insertion depth of 8 cm, the temperature elevations were 39.9 ± 4.7°C and 23.2±6.5°C without and with gel, respectively (P < 0.001). For an insertion depth of 10 cm, the temperature elevations were 20.8 ± 1.5°C and 14.4 ± 1.5°C without and with gel, respectively (P < 0.001). The maximal temperature elevations corresponding to an 8 cm insertion depth with gel were comparable with those corresponding to a 10 cm insertion depth without gel. Similarly, the maximal temperature elevations (12.2 ± 1.8°C) corresponding to 12 cm insertion depth without gel were comparable to those corresponding to 10 cm insertion depth with gel. Applying ultrasound gel at the applicator insertion site can significantly reduce temperature elevations at the tissue surface during MWA procedures.
MRI-guided focused ultrasound ablation of painful lumbar facet joints: a retrospective assessment of safety and tolerability in human subjects
Abstract Objective To evaluate the safety and tolerability of MRI-guided focused ultrasound (MRgFUS) for the treatment of facet joint–mediated pain in human subjects for whom conventional treatment had failed. Secondarily, to evaluate effectiveness of the procedure. Methods Consecutive patients who underwent MRgFUS at our institution were retrospectively identified. Chart review was performed to obtain relevant clinical and technical data. All patients had chronic low back pain and positive comparative medial branch blocks. Results Twenty-six MRgFUS treatments in 20 patients were included. Mean sonication energy was 1436.6 Joules. The procedure was technically successful in all patients. Of the treated patients, 29.6% experienced short-term worsening of low back pain immediately after the procedure, all by 1–4 points on a 0–10 scale. One patient (3.8%) reported temporary worsening of preexisting radicular symptoms after the procedure. Of 21 treatments with clinical follow-up of at least 3 months available, 12 (57.1%) had >3 months’ pain relief, 2 (10%) had <3 months’ benefit, 6 (30%) reported no benefit, and 1 (5%) patient was lost to follow-up. In patients who reported at least some benefit with prior conventional radiofrequency ablation, 8/10 (80%) benefited from the MRgFUS procedure. Conclusion The present study demonstrates that MRgFUS ablation of the lumbar facet joints is a safe and tolerable procedure in human subjects and could provide another option for patients for whom radiofrequency ablation had failed. More than half of all patients received significant durable pain relief, which jumped to 80% for patients who had experienced at least some benefit from prior radiofrequency ablations.
MR-guided Cryoablation for the Treatment of Symptomatic Pedal Vascular Malformations
Objective: Vascular malformations are benign vascular anomalies characterized by abnormally developed arterial, venous, and lymphatic structures, which are often symptomatic. Historical and current treatment techniques include intravascular embolization/sclerosis and surgical resection. While these techniques have proven to be successful at managing and treating these types of lesions, these techniques are not without risk, especially in the small spaces of the hands and feet. Cryoablation for the treatment of low-flow vascular malformations is a new and evolving technique. We present five cases of symptomatic pedal vascular malformations treated with MR guided cryoablation, which provides encouraging safety and feasibility results for these difficult to treat lesions. Methods: A retrospective review of patients who had undergone MR-guided cryoablation of their pedal vascular malformations between January 2016 and January 2020 was performed. Results: Five cryoablations were completed without immediate complication. All patients reported markedly decreased pain corresponding to the treated area and improvement in their ability to return to a more active lifestyle. Two patients experienced mild transient numbness which resolved by 2–3 months and one patient experienced a transient motor and sensory neuropathy which resolved by 6 months. Conclusion: We present five cases of successful MR-guided cryoablation of symptomatic pedal venous malformations. Many of the patients included in this review failed conservative and other interventional/surgical treatments. The treatment options for this patient cohort can be limited given small space within the plantar aspect of the foot. Cryoablation of these lesions can be performed safely especially under continuous MRI monitoring. Level of Evidence: Case series (Level 4)
Body Interventional MRI for Diagnostic and Interventional Radiologists: Current Practice and Future Prospects
Background: Women with uterine fibroids often seek uterine-preserving treatments, rather than hysterectomy. Imaging-defined endpoints following nonsurgical treatments for fibroids are limited. Materials and Methods: Fibroid Interventions: Reducing Symptoms Today and Tomorrow (FIRSTT), a randomized controlled trial of uterine artery embolization (UAE) versus magnetic resonance imaging-guided focused ultrasound surgery (MRgFUS), enrolled premenopausal women with symptomatic uterine fibroids. In this subanalysis, we report imaging results up to 36 months after UAE or MRgFUS. Magnetic resonance imaging (MRI) was performed at baseline for all women and during the 36 months after treatment if they did not meet other study endpoints. The main outcome of this subanalysis was fibroid volume reduction (defined both in terms of total fibroid load and volume of the largest fibroid), uterine volume reduction, and nonperfused volume. Results: During 2010–2014, 25 of the 37 women who were randomized and treated at Mayo Clinic had a 24-month follow-up MRI (11 UAE; 14 MRgFUS); among these women, 15 (7 UAE and 8 MRgFUS) had a 36-month follow-up MRI. Average age for the cohort was 44.1 (standard deviation, SD = 4.4) years. Nine patients had a second fibroid procedure by 36 months (seven in the MRgFUS arm and two in UAE arm). Median total fibroid load reduction was ∼50% in both treatment arms at both 24- and 36-month follow-up. Volume of the largest fibroid decreased more in the MRgFUS arm, whereas uterine volume decreased more in the UAE arm (neither reached statistical significance). At 24 months, median nonperfused volume was higher in the UAE arm (92%) than the MRgFUS arm (10%). Conclusions: Similar fibroid volume reduction was seen for the MRgFUS and UAE treatments in this comparative effectiveness study. Nonperfused volume 24 months after the procedure was higher in the UAE arm than in the MRgFUS arm. Clinical Trial Registration Number: NCT00995878, clinicaltrials.gov
Using Black Bone Magnetic Resonance Imaging for Fibula Free Flap Surgical Planning: A Means to Reduce Radiation Exposure with Accurate Surgical Outcomes
Summary: Advances in virtual surgical planning and three-dimensionally–printed guides have enabled increased precision in vascularized free fibula flap reconstruction of the mandible and valuable preoperative planning. However, virtual surgical planning currently requires high-resolution computed tomographic scans, exposing patients to ionizing radiation. The aim of this study was to determine whether black bone magnetic resonance imaging can be used for accurate surgical planning and three-dimensionally–printed guide creation, thus reducing patient radiation exposure. This study included 10 cadaver heads and 10 cadaver lower extremities. A mock fibula free flap for mandible reconstruction was performed. Five operations were planned with guides created using black bone magnetic resonance imaging, whereas the other five were planned and performed using guides created with computed tomographic scan data. All specimens underwent a postoperative computed tomographic scan, and three-dimensional reconstruction of scans was performed and surgical accuracy to the planned surgery was assessed. Guides created from black bone magnetic resonance imaging demonstrated high accuracy to the surgical plan. There was no statistically significant difference in postoperative deviation from the plan when black bone magnetic resonance imaging versus computed tomographic scanning was used for virtual surgical planning and guide creation. Both modalities led to a postoperative positive or negative deviation from the virtual plan within 0.8 mm. This study demonstrates that virtual surgical planning and three-dimensionally–printed guide creation for free fibula flaps for mandible reconstruction can be performed using black bone magnetic resonance imaging with comparable accuracy to computed tomographic scanning. This could reduce radiation exposure for patients and enable a more streamlined imaging process for head and neck cancer patients.
Symptom-specific differential motor network modulation by deep brain stimulation in Parkinson’s disease
OBJECTIVE Deep brain stimulation (DBS) of the subthalamic nucleus (STN) is an established neurosurgical treatment for the motor symptoms of Parkinson’s disease (PD). While often highly effective, DBS does not always yield optimal therapeutic outcomes, and stimulation-induced adverse effects, including paresthesia, muscle contractions, and nausea/lightheadedness, commonly occur and can limit the efficacy of stimulation. Currently, objective metrics do not exist for monitoring neural changes associated with stimulation-induced therapeutic and adverse effects. METHODS In the present study, the authors combined intraoperative functional MRI (fMRI) with STN DBS in 20 patients with PD to test the hypothesis that stimulation-induced blood oxygen level–dependent signals contained predictive information concerning the therapeutic and adverse effects of stimulation. RESULTS As expected, DBS resulted in blood oxygen level–dependent activation in myriad motor regions, including the primary motor cortex, caudate, putamen, thalamus, midbrain, and cerebellum. Across the patients, DBS-induced improvements in contralateral Unified Parkinson’s Disease Rating Scale tremor subscores correlated with activation of thalamic, brainstem, and cerebellar regions. In addition, improvements in rigidity and bradykinesia subscores correlated with activation of the primary motor cortex. Finally, activation of specific sensorimotor-related subregions correlated with the presence of DBS-induced adverse effects, including paresthesia and nausea (cerebellar cortex, sensorimotor cortex) and unwanted muscle contractions (caudate and putamen). CONCLUSIONS These results suggest that DBS-induced activation patterns revealed by fMRI contain predictive information with respect to the therapeutic and adverse effects of DBS. The use of fMRI in combination with DBS therefore may hold translational potential to guide and improve clinical stimulator optimization in patients.