Abstract Background Flow‐related ghost artifact from a 3D Magnetization Prepared Rapid Gradient Echo (MPRAGE) sequence results from unsaturated magnetization of incoming arterial flow. This is especially common on MR scanners equipped with smaller radiofrequency (RF) transmit coils. A high‐performance compact 3T (C3T) scanner features a smaller RF‐transmit coil (inner diameter 37 cm, length 40 cm), leading to a rapid fall‐off of the B1 field below the neck. This configuration results in more intense flow‐related ghost artifacts, especially in younger patients. Purpose The C3T scanner's smaller RF‐transmit coil provides RF field coverage over the brain region, causing bright in‐flow arterial signals and flow‐related artifacts in the conventional 3D‐MPRAGE scans. The purpose of this study is to suppress these artifacts by adding a RF saturation band (RFSB) pulses to the 3D‐MPRAGE sequence. Methods The RFSB was added to the 3D‐MPRAGE sequence as a preparation pulse option. To test the effectiveness, 37 subjects were scanned on the C3T under an IRB‐approved protocol using 3D‐MPRAGE with and without RFSB. Ten of those subjects underwent repeated scans with and without RFSB to evaluate test‐retest reliability. A consensus evaluation by two neuroradiologists was performed on all data to compare signal to noise ratio, image contrast, presence of artifacts, and diagnostic confidence. Quantitative analysis included calculating test‐retest differences by image subtraction and evaluating the variance in flow‐artifact‐induced image intensity between the scans with and without RFSB. Additionally, one subject was scanned on a whole‐body 3T scanner using a transmit/receive (T/R) head coil to demonstrate the method's applicability across different MRI platforms as a proof of concept. Results The Wilcoxon signed‐rank test of the neuroradiologist evaluations showed a significant reduction in artifacts and an improvement in diagnostic confidence in the posterior fossa region with and without RFSB ( p < 0.0001). Test–retest analysis showed that adding RFSB significantly reduced image intensity variability in the cerebellum, even among subjects without visible flow artifacts. The normalized difference decreased from 8.71% to 6.41% ( p = 0.0059), suggesting improved image reliability in regions prone to flow‐related artifacts. Additionally, similar findings were observed in scans on a whole‐body 3T with a T/R head coil, demonstrating the broader applicability of this method. Conclusion Incorporating RFSB into 3D‐MPRAGE scans effectively reduces flow‐related ghost artifact on the C3T scanner, improving image quality and diagnostic confidence. These findings suggest that the proposed method could be widely implemented across MRI systems utilizing a smaller RF‐transmit coil.
Improved Resting-State Functional MRI Using Multi-Echo Echo-Planar Imaging on a Compact 3T MRI Scanner with High-Performance Gradients
In blood-oxygen-level-dependent (BOLD)-based resting-state functional (RS-fMRI) studies, usage of multi-echo echo-planar-imaging (ME-EPI) is limited due to unacceptable late echo times when high spatial resolution is used. Equipped with high-performance gradients, the compact 3T MRI system (C3T) enables a three-echo whole-brain ME-EPI protocol with smaller than 2.5 mm isotropic voxel and shorter than 1 s repetition time, as required in landmark fMRI studies. The performance of the ME-EPI was comprehensively evaluated with signal variance reduction and region-of-interest-, seed- and independent-component-analysis-based functional connectivity analyses and compared with a counterpart of single-echo EPI with the shortest TR possible. Through the multi-echo combination, the thermal noise level is reduced. Functional connectivity, as well as signal intensity, are recovered in the medial orbital sulcus and anterior transverse collateral sulcus in ME-EPI. It is demonstrated that ME-EPI provides superior sensitivity and accuracy for detecting functional connectivity and/or brain networks in comparison with single-echo EPI. In conclusion, the high-performance gradient enabled high-spatial-temporal resolution ME-EPI would be the method of choice for RS-fMRI study on the C3T.