Back to Authors

McDonald, Robert J.

https://orcid.org/0000-0002-6409-6799

Mayo Clinic

Mayo Clinic

Citations 32

First-in-Human Safety and Feasibility of Nodal and Pedal MR Lymphangiography with Gadopiclenol
Thompson, Scott M. , Collins, Jeremy D. , Bendel, Emily C. , Reisenauer, Christopher J., Jundt, Michael C., Yalҫin, Müge, Favazza, Christopher , Lu, Aiming , McDonald, Robert J. , Williamson, Eric E. , Stinson, Eric G. , In, MyungHo, Favazza, Christopher P , Messina, Steven A , Collins, Jeremy , Williamson, Eric , Thompson, Scott , Bendel, Emily , In, Myung-Ho , Jundt, Michael C., In, Myung‐Ho , Messina, Steven A.

Radiology: Cardiothoracic Imaging | July 2, 2026 | Volume: 8 | Issue: 4 | Pages: No page available

10.1148/ryct.260067 Get It

Dynamic gadopiclenol-enhanced nodal and pedal MR lymphangiography was safe, with no adverse events, and feasible for imaging peripheral and central conducting lymphatic anatomy.
Hyaluronidase Injection for Prevention of Moderate or Severe Complications After Contrast Media Extravasation: A Propensity Score–Matched Analysis
Schmitz, John J. , McDonald, Robert J. , McDonald, Jennifer S.

American Journal of Roentgenology | October 30, 2024 | Volume: 224 | Issue: 3 | Pages: No page available

10.2214/ajr.24.31986 Get It

Contrast Media in Pregnant and Lactating Patients, From the AJR Special Series on Contrast Media
Bookwalter, Candice A., McDonald, Robert J. , Packard, Annie T. , Little, Jason T. , Watson, Robert E. , McDonald, Jennifer S.

American Journal of Roentgenology | July 24, 2024 | Volume: 224 | Issue: 4 | Pages: No page available

10.2214/ajr.24.31415 Get It

Risk of Acute Kidney Injury Following IV Iodinated Contrast Media Exposure: 2023 Update, From the AJR Special Series on Contrast Media
McDonald, Robert J. , McDonald, Jennifer S.

American Journal of Roentgenology | October 4, 2023 | Volume: 223 | Issue: 1 | Pages: No page available

10.2214/ajr.23.30037 Get It

No Increased Mercury Release from Dental Restorations at 1.5T, 3T, or 7T MRI
Burkett, Brian J. , Rasmussen, Chad M. , Fillmore, W. Jonathan , McDonald, Robert J. , Fagan, Andrew , Erdahl, Sarah A , Eckdahl, Steven J., Welker, Kirk M. , Fagan, Andrew J , Burkett, Brian , McDonald, Jennifer S.

Magnetic Resonance in Medicine | September 27, 2023 | Volume: 91 | Issue: 2 | Pages: 660-669

10.1002/mrm.29872 Get It

AbstractPurposeDental amalgam contains mercury and is commonly used in dental restorations. The impact of MRI on mercury excretion from dental amalgam is not well understood across clinical field strengths, especially 7T. We investigated the effects of MRI exposure on mercury excretion using fresh, lab‐created dental amalgam restorations and in extracted teeth with old, pre‐existing restorations.MethodsDonated, unfilled human teeth (n = 120) were restored with amalgam before being stored in saline, artificial saliva, or a dry box prior to MRI scanning. The teeth were placed in individual tubes of fresh artificial saliva and scanned at 1.5T, 3T, or 7T or left unscanned as controls. Mercury concentrations were measured 24–30 h later. Donated teeth with pre‐existing restorations (n = 40) were stored in artificial saliva, scanned at 7T or left unscanned as controls, and mercury concentration tested.ResultsFor teeth extracted and restored in a laboratory, no significant difference was found (F = 2.42, P = 0.072) between mean mercury concentrations of unscanned teeth (13.72 μg/L) and teeth scanned at 1.5T (10.88 μg/L), 3T (12.65 μg/L), or 7T (8.88 μg/L). For teeth extracted with previously placed restorations, no significant difference (P = 0.288) was found between unscanned controls (4.28 μg/L) and teeth scanned at 7T (6.63 μg/L).ConclusionMRI of dental amalgam does not significantly increase mercury excretion at 1.5T, 3T, or 7T compared to unscanned teeth. This holds true for controlled laboratory restorations as well as for those placed and lived with prior to extraction and scanning, demonstrating no added risk to the clinical patient or research subject.
Percutaneous vertebroplasty: Overview, clinical applications, and current state
McDonald, Robert J. , Lane, John I. , Wald, John T. , Diehn, Felix E.

Applied Radiology | April 4, 2022 | Volume: No volume available | Issue: No issue available | Pages: 24-30

10.37549/ar2346 Get It

Prevention of Allergic-like Reactions at Repeat CT: Steroid Pretreatment versus Contrast Material Substitution
McDonald, Jennifer S. , Larson, Nicholas B. , Kolbe, Amy B. , Schmitz, John J. , Maddox, Daniel E. , Hartman, Robert P. , Kallmes, David F. , McDonald, Robert J. , Hunt, Christopher H , Schmitz, John J , Maddox, Daniel E , Hartman, Robert P , Kallmes, David F , McDonald, Robert J , Larson, Nicholas B , Hunt, Christopher H.

Radiology | August 3, 2021 | Volume: 301 | Issue: 1 | Pages: 133-140

10.1148/radiol.2021210490 Get It

Giant torus mandibularis causing submandibular duct obstruction and sialadenitis
Madhavan, Ajay A. , McDonald, Robert J. , Verdoorn, Jared T. , Verdoorn, Jared T , Madhavan, Ajay A , Diehn, Felix E. , Carr, Carrie M.

The Neuroradiology Journal | December 14, 2020 | Volume: 34 | Issue: 3 | Pages: 249-252

10.1177/1971400920978431 Get It

Torus mandibularis is a benign osseous overgrowth arising from the lingual surface of the mandible. It is a common, incidental finding on imaging due to its relatively high prevalence. In the majority of cases, mandibular tori are asymptomatic. We report a novel presentation of a giant torus mandibularis causing bilateral obstruction of the submandibular ducts and consequent sialadenitis. Our patient presented with progressive pain centered in the floor of his mouth and had bilateral submandibular glandular enlargement on exam. Computed tomography showed a giant right torus mandibularis, which was causing obstruction and dilation of the bilateral submandibular ducts. Although conservative management was attempted, he ultimately underwent surgical resection of his torus with symptomatic improvement. This patient highlights a novel complication of torus mandibularis and illustrates successful treatment. Though not previously described, this complication may be underreported and should be considered in the appropriate clinical setting.
Acute Reactions to Gadolinium-Based Contrast Agents in a Pediatric Cohort: A Retrospective Study of 16,237 Injections
Larson, Nicholas B. , Kolbe, Amy B. , Schmitz, John J. , Kallmes, David F. , McDonald, Robert J. , Larson, Nicholas B , McDonald, Jennifer S. , Hunt, Christopher H.

American Journal of Roentgenology | July 29, 2020 | Volume: 216 | Issue: 5 | Pages: 1363-1369

10.2214/ajr.20.23602 Get It