Reply to “Letter to Editor by Dr. Steckner Regarding ‘Induction of Extremely Severe Nausea via Vestibular Activation on a 7 Tesla MRI Scanner’ by Fagan et al.”
Fagan, Andrew , Fagan, Andrew J

Journal of Magnetic Resonance Imaging | August 20, 2025 | Volume: 62 | Issue: 4 | Pages: 1234-1234

10.1002/jmri.70085 Get It

Induction of Extremely Severe Nausea via Vestibular Activation on a 7 Tesla MRI Scanner
Fagan, Andrew , Amrami, Kimberly K. , Watson, Robert E. , Anjum, Muhammad, Welker, Kirk M. , Fagan, Andrew J , Anjum, Muhammad A R

Journal of Magnetic Resonance Imaging | November 7, 2024 | Volume: 61 | Issue: 6 | Pages: 2644-2647

10.1002/jmri.29656 Get It

Extremely severe nausea was experienced by four subjects positioned prone on a 7T scanner table with their arm extended overhead for a wrist examination and their head positioned approximately 10–20 cm above the magnet's central axis. Movement through the large static and spatial field gradients of current 7T MRI scanner magnets typically causes mild vestibular activation which is well tolerated by most individuals. However, when positioned off‐axis, the head moves through regions of even larger and more rapidly changing magnetic fields which in the current study were sufficient to induce the extremely severe nausea. Ensuring the head remains on‐axis mitigates this effect.
No Increased Mercury Release from Dental Restorations at 1.5T, 3T, or 7T MRI
Burkett, Brian J. , Rasmussen, Chad M. , Fillmore, W. Jonathan , McDonald, Robert J. , Fagan, Andrew , Erdahl, Sarah A , Eckdahl, Steven J., Welker, Kirk M. , Fagan, Andrew J , Burkett, Brian , McDonald, Jennifer S.

Magnetic Resonance in Medicine | September 27, 2023 | Volume: 91 | Issue: 2 | Pages: 660-669

10.1002/mrm.29872 Get It

AbstractPurposeDental amalgam contains mercury and is commonly used in dental restorations. The impact of MRI on mercury excretion from dental amalgam is not well understood across clinical field strengths, especially 7T. We investigated the effects of MRI exposure on mercury excretion using fresh, lab‐created dental amalgam restorations and in extracted teeth with old, pre‐existing restorations.MethodsDonated, unfilled human teeth (n = 120) were restored with amalgam before being stored in saline, artificial saliva, or a dry box prior to MRI scanning. The teeth were placed in individual tubes of fresh artificial saliva and scanned at 1.5T, 3T, or 7T or left unscanned as controls. Mercury concentrations were measured 24–30 h later. Donated teeth with pre‐existing restorations (n = 40) were stored in artificial saliva, scanned at 7T or left unscanned as controls, and mercury concentration tested.ResultsFor teeth extracted and restored in a laboratory, no significant difference was found (F = 2.42, P = 0.072) between mean mercury concentrations of unscanned teeth (13.72 μg/L) and teeth scanned at 1.5T (10.88 μg/L), 3T (12.65 μg/L), or 7T (8.88 μg/L). For teeth extracted with previously placed restorations, no significant difference (P = 0.288) was found between unscanned controls (4.28 μg/L) and teeth scanned at 7T (6.63 μg/L).ConclusionMRI of dental amalgam does not significantly increase mercury excretion at 1.5T, 3T, or 7T compared to unscanned teeth. This holds true for controlled laboratory restorations as well as for those placed and lived with prior to extraction and scanning, demonstrating no added risk to the clinical patient or research subject.
7T MR Thermometry technique for validation of system‐predicted SAR with a home‐built radiofrequency wrist coil
Fagan, Andrew , Jacobs, Paul , Hulshizer, Thomas C., Rossman, Phillip J. , Frick, Matthew A., Amrami, Kimberly K. , Felmlee, Joel P. , Jacobs, Paul S, Fagan, Andrew J

Medical Physics | December 10, 2020 | Volume: 48 | Issue: 2 | Pages: 781-790

10.1002/mp.14641 Get It

PurposeA 7T magnetic resonance thermometry (MRT) technique was developed to validate the conversion factor between the system‐measured transmitted radiofrequency (RF) power into a home‐built RF wrist coil with the system‐predicted SAR value. The conversion factor for a new RF coil developed for ultra high magnetic field MRI systems is used to ensure that regulatory limits on RF energy deposition in tissue, specifically the local 10g‐averaged specific absorption rate (SAR10g), are not exceeded. MRT can be used to validate this factor by ensuring that MRT‐measured SAR values do not exceed those predicted by the system.MethodsA 14‐cm diameter high‐pass birdcage RF coil was built to image the wrist at 7T. A high spatial and temporal resolution dual‐echo gradient echo MRT technique, incorporating quasi‐simultaneous RF‐induced heating and temperature change measurements using the proton resonance frequency method, was developed. The technique allowed for high‐temperature resolution measurements (~±0.1°C) to be performed every 20 s over a 4‐min heating period, with high spatial resolution (2.56 mm3 voxel size) and avoiding phase discontinuities arising from severe magnetic susceptibility‐induced B0 inhomogeneities. Magnetic resonance thermometry was performed on a phantom made from polyvinylpyrrolidone to mimic the dielectric properties of muscle tissue at 297.2 MHz. Temperature changes measured with MRT and four fiber optic temperature sensors embedded in the phantom were compared. Electromagnetic simulations of the coil and phantom were developed and validated via comparison of simulated and measured B1+ maps in the phantom. The position of maximum SAR within the coil was determined from simulations, and MRT was performed within a wrist‐sized piece of meat positioned at that SAR hotspot location. MRT‐measured and system‐predicted SAR values for the phantom and meat were compared.ResultsTemperature change measurements from MRT matched closely to those from the fiber optic temperature sensors. The simulations were validated via close correlation between the simulated and MRT‐measured B1+ and SAR maps. Using a coil conversion factor of 2 kg−1, MRT‐measured point‐SAR values did not exceed the system‐predicted SAR10g in either the uniform phantom or in the piece of meat mimicking the wrist located at the SAR hotspot location.ConclusionsA highly accurate MRT technique with high spatial and temporal resolution was developed. This technique can be used to ensure that system‐predicted SAR values are not exceeded in practice, thereby providing independent validation of SAR levels delivered by a newly built RF wrist coil. The MRT technique is readily generalizable to perform safety evaluations for other RF coils at 7T.
7T MR Safety
Fagan, Andrew , Bitz, Andreas K., Björkman‐Burtscher, Isabella M. , Collins, Christopher M. , Kimbrell, Vera , Raaijmakers, Alexander , Metzger, Gregory J. , Fagan, Andrew J

Journal of Magnetic Resonance Imaging | August 24, 2020 | Volume: 53 | Issue: 2 | Pages: 333-346

10.1002/jmri.27319 Get It

Magnetic resonance imaging and spectroscopy (MRI/MRS) at 7T represents an exciting advance in MR technology, with intriguing possibilities to enhance image spatial, spectral, and contrast resolution. To ensure the safe use of this technology while still harnessing its potential, clinical staff and researchers need to be cognizant of some safety concerns arising from the increased magnetic field strength and higher Larmor frequency. The higher static magnetic fields give rise to enhanced transient bioeffects and an increased risk of adverse incidents related to electrically conductive implants. Many technical challenges remain and the continuing rapid pace of development of 7T MRI/MRS is likely to present further challenges to ensuring safety of this technology in the years ahead. The recent regulatory clearance for clinical diagnostic imaging at 7T will likely increase the installed base of 7T systems, particularly in hospital environments with little prior ultrahigh‐field MR experience. Informed risk/benefit analyses will be required, particularly where implant manufacturer‐published 7T safety guidelines for implants are unavailable. On behalf of the International Society for Magnetic Resonance in Medicine, the aim of this article is to provide a reference document to assist institutions developing local institutional policies and procedures that are specific to the safe operation of 7T MRI/MRS. Details of current 7T technology and the physics underpinning its functionality are reviewed, with the aim of supporting efforts to expand the use of 7T MRI/MRS in both research and clinical environments. Current gaps in knowledge are also identified, where additional research and development are required. Level of Evidence 5 Technical Efficacy 2 J. MAGN. RESON. IMAGING 2021;53:333–346.
Multimodal Breast Phantoms for Microwave, Ultrasound, Mammography, Magnetic Resonance and Computed Tomography Imaging
Ruvio, Giuseppe , Solimene, Raffaele , Cuccaro, Antonio , Fiaschetti, Gaia, Fagan, Andrew , Cournane, Seán , Cooke, Jennie , Ammann, Max J. , Vasquez, J. A. Tobón , Browne, Jacinta E. , Fagan, Andrew J , Tobon, Jorge , Browne, Jacinta

Sensors | April 23, 2020 | Volume: 20 | Issue: 8 | Pages: 2400

10.3390/s20082400 Get It

The aim of this work was to develop multimodal anthropomorphic breast phantoms suitable for evaluating the imaging performance of a recently-introduced Microwave Imaging (MWI) technique in comparison to the established diagnostic imaging modalities of Magnetic Resonance Imaging (MRI), Ultrasound (US), mammography and Computed Tomography (CT). MWI is an emerging technique with significant potential to supplement established imaging techniques to improve diagnostic confidence for breast cancer detection. To date, numerical simulations have been used to assess the different MWI scanning and image reconstruction algorithms in current use, while only a few clinical trials have been conducted. To bridge the gap between the numerical simulation environment and a more realistic diagnostic scenario, anthropomorphic phantoms which mimic breast tissues in terms of their heterogeneity, anatomy, morphology, and mechanical and dielectric characteristics, may be used. Key in this regard is achieving realism in the imaging appearance of the different healthy and pathologic tissue types for each of the modalities, taking into consideration the differing imaging and contrast mechanisms for each modality. Suitable phantoms can thus be used by radiologists to correlate image findings between the emerging MWI technique and the more familiar images generated by the conventional modalities. Two phantoms were developed in this study, representing difficult-to-image and easy-to-image patients: the former contained a complex boundary between the mammary fat and fibroglandular tissues, extracted from real patient MRI datasets, while the latter contained a simpler and less morphologically accurate interface. Both phantoms were otherwise identical, with tissue-mimicking materials (TMMs) developed to mimic skin, subcutaneous fat, fibroglandular tissue, tumor and pectoral muscle. The phantoms’ construction used non-toxic materials, and they were inexpensive and relatively easy to manufacture. Both phantoms were scanned using conventional modalities (MRI, US, mammography and CT) and a recently introduced MWI radar detection procedure called in-coherent Multiple Signal Classification (I-MUSIC). Clinically realistic artifact-free images of the anthropomorphic breast phantoms were obtained using the conventional imaging techniques as well as the emerging technique of MWI.
Image Artifact Management for Clinical Magnetic Resonance Imaging on a 7 T Scanner Using Single-Channel Radiofrequency Transmit Mode
Fagan, Andrew , Welker, Kirk M. , Amrami, Kimberly K. , Frick, Matthew A., Watson, Robert E. , Kollasch, Peter , Chebrolu, Venkata V. , Felmlee, Joel P. , Fagan, Andrew J

Investigative Radiology | September 10, 2019 | Volume: 54 | Issue: 12 | Pages: 781-791

10.1097/rli.0000000000000598 Get It

Objectives The aim of this work was to devise mitigation strategies for addressing a range of image artifacts on a clinical 7 T magnetic resonance imaging scanner using the regulatory-approved single-channel radiofrequency transmit mode and vendor-supplied radiofrequency coils to facilitate clinical scanning within reasonable scan times. Materials and Methods Optimized imaging sequence protocols were developed for routine musculoskeletal knee and neurological imaging. Sources of severe image nonuniformities were identified, and mitigation strategies were devised. A range of custom-made high permittivity dielectric pads were used to compensate for B1 + and B1 − inhomogeneities, and also for magnetic susceptibility-induced signal dropouts particularly in the basal regions of the temporal lobes and in the cerebellum. Results Significant improvements in image uniformity were obtained using dielectric pads in the knee and brain. A combination of small voxels, reduced field of view B0 shimming, and high in-plane parallel imaging factors helped to minimize signal loss in areas of high susceptibility-induced field distortions. The high inherent signal-to-noise ratio at 7 T allowed for high receiver bandwidths and thin slices to minimize chemical shift artifacts. Intermittent artifacts due to radiofrequency inversion pulse limitations (power, bandwidth) were minimized with dielectric pads. A patient with 2 implanted metallic cranial fixation devices located within the radiofrequency transmit field was successfully imaged, with minimal image geometric distortions. Conclusions Challenges relating to severe image artifacts at 7 T using single-channel radiofrequency transmit functionality in the knee and brain were overcome using the approaches described in this article. The resultant high diagnostic image quality paves the way for incorporation of this technology into the routine clinical workflow. Further developmental efforts are required to expand the range of applications to other anatomical areas, and to expand the evidence- and knowledge-base relating to the safety of scanning patients with implanted metallic devices.
DCE‐MRI protocol for constraining absolute pharmacokinetic modeling errors within specific accuracy limits
Knight, Silvin P. , Meaney, James F. , Fagan, Andrew , Fagan, Andrew J

Medical Physics | May 31, 2019 | Volume: 46 | Issue: 8 | Pages: 3592-3602

10.1002/mp.13635 Get It

PurposeTo quantify the effects of DCE acquisition and pharmacokinetic modeling processing methodologies on the absolute accuracy and precision of derived pharmacokinetic (PK) parameter values using a novel anthropomorphic phantom test device in which “ground truth” values were known a priori.MethodsGround truth arterial input function (AIF), tumor, and healthy tissue contrast agent concentration‐time curves (CTCs) were established within the phantom and repeatedly measured on a 3T MRI scanner with varying temporal resolution (Tres = 1.22–30.6 s). Ground truth CTCs, Ktrans, ve, and kep values were directly compared to measured values as a function of Tres, with and without the application of voxel‐wise flip‐angle corrections applied to the data and PK modeling performed using linear and nonlinear forms of the standard Tofts model.ResultsMeasurement of the AIF was strongly affected by the Tres used (AIF curve‐shape feature errors: 3%–222% for Tres: 1.22–30.6 s), which directly translated to errors in the derived Ktrans, ve, and kep values of 1%–24%, 2%–5%, and 1%–26% respectively across this Tres range (flip‐angle correction applied). Further appreciable improvements in accuracy and precision arising from the use of flip angle corrections and nonlinear least squares fitting were quantified and used to identify optimal acquisition and analysis methodologies for which measurement errors could be constrained below threshold levels.ConclusionThis quantitative study provides insight into how errors in AIF measurement propagate to errors in PK parameter outputs. Absolute quantification of the accuracy and precision of MR‐measured CTCs, and resultant PK parameter values, allowed for an optimal temporal resolution to be defined commensurate with maintaining Ktrans, ve, and kep measurement errors below 5% and 10% levels. An appreciable gain in PK parameter estimation accuracy at the analysis stage was also demonstrated using flip‐angle corrections and a linear approach to PK model fitting.
Uniform combined reconstruction of multichannel 7T knee MRI receive coil data without the use of a reference scan
Chebrolu, Venkata V. , Kollasch, Peter , Deshpande, Vibhas , Grinstead, John, Howe, Benjamin M., Frick, Matthew A., Fagan, Andrew , Benner, Thomas, Heidemann, Robin M. , Felmlee, Joel P. , Amrami, Kimberly K. , Chebrolu, Venkata Veerendranadh , Fagan, Andrew J , Howe, Benjamin M.

Journal of Magnetic Resonance Imaging | February 19, 2019 | Volume: 50 | Issue: 5 | Pages: 1534-1544

10.1002/jmri.26691 Get It

BackgroundMR image intensity nonuniformity is often observed at 7T. Reference scans from the body coil used for uniformity correction at lower field strengths are typically not available at 7T.PurposeTo evaluate the efficacy of a novel algorithm, Uniform Combined Reconstruction (UNICORN), to correct receive coil‐induced nonuniformity in musculoskeletal 7T MRI without the use of a reference scan.Study TypeRetrospective image analysis study.SubjectsMRI data of 20 subjects was retrospectively processed offline.Field Strength/Sequence: Knees of 20 subjects were imaged at 7T with a single‐channel transmit, 28‐channel phased‐array receive knee coil. A turbo‐spin‐echo sequence was used to acquire 33 series of images.AssessmentThree fellowship‐trained musculoskeletal radiologists with cumulative experience of 42 years reviewed the images. The uniformity, contrast, signal‐to‐noise ratio (SNR), and overall image quality were evaluated for images with no postprocessing, images processed with N4 bias field correction algorithm, and the UNICORN algorithm.Statistical TestsIntraclass correlation coefficient (ICC) was used for measuring the interrater reliability. ICC and 95% confidence intervals (CIs) were calculated using the R statistical package employing a two‐way mixed‐effects model based on a mean rating (k = 3) for absolute agreement. The Wilcoxon signed‐rank test with continuity correction was used for analyzing the overall image quality scores.ResultsUNICORN was preferred among the three methods evaluated for uniformity in 97.9% of the pooled ratings, with excellent interrater agreement (ICC of 0.98, CI 0.97–0.99). UNICORN was also rated better than N4 for contrast and equivalent to N4 in SNR with ICCs of 0.80 (CI 0.72–0.86) and 0.67 (CI 0.54–0.77), respectively. The overall image quality scores for UNICORN were significantly higher than N4 (P < 6 × 10‐13), with good to excellent interrater agreement (ICC 0.90, CI 0.86–0.93).Data ConclusionWithout the use of a reference scan, UNICORN provides better image uniformity, contrast, and overall image quality at 7T compared with the N4 bias field‐correction algorithm.Level of Evidence: 4Technical Efficacy: Stage 1J. Magn. Reson. Imaging 2019;50:1534–1544.