Application of high‐density 2D receiver coil arrays for improved SNR in prostate MRI
Riederer, Stephen J. , Borisch, Eric A. , Du, Qingshuo, Froemming, Adam T. , Hulshizer, Thomas C., McGee, Kiaran P. , Robb, Fraser , Rossman, Phillip J. , Takahashi, Naoki , Riederer, Stephen J , Takahashi, Naoki , Kawashima, Akira

Magnetic Resonance in Medicine | September 26, 2024 | Volume: 93 | Issue: 2 | Pages: 850-863

10.1002/mrm.30289 Get It

AbstractPurposeTo study if adaptive image receive (AIR) receiver coil elements can be configured into a 2D array with high (>45% by diameter) element‐to‐element overlap, allowing improved SNR at depth (0.7–1.5× element diameter) versus conventional (20%) overlap.MethodsAn anterior array composed of twenty 10‐cm diameter elements with 45% overlap arranged into a 4 × 5 grid and a similar 3 × 7 twenty‐one‐element posterior array were constructed. SNR and g‐factor were measured in a pelvic phantom using the new high‐density (HD) arrays (41 total elements) and compared to vendor AIR‐based arrays (30 total elements) with conventional overlap. T2‐weighted fast‐spin‐echo (T2SE) images acquired using both arrays were compared in 20 subjects. SNR was estimated in vivo. Results were compared blindly by three uroradiologists using a five‐point scale. Images using the HD arrays were also compared to a set of images acquired over a range of acceleration factors (R = 2.0, 2.5, 3.0) with the conventional arrays.ResultsSNR within the phantom was on average 15% higher for R = 1.0, 1.5, and 2.0 using the HD arrays. Across the 20 subjects SNR within the prostate was 11% higher and assessed radiologically as significantly higher (p < 0.001) for the HD versus conventional arrays. At all acceleration factors the new HD arrays outperformed the conventional arrays (p ≤ 0.01), allowing increased R for similar SNR.ConclusionAIR elements can be configured into 2D arrays with high (45%) element‐to‐element overlap, consistently providing increased SNR at depth versus arrays with conventional (20%) overlap. The SNR improvement allows increased acceleration in T2SE prostate MRI.
7T MR Thermometry technique for validation of system‐predicted SAR with a home‐built radiofrequency wrist coil
Fagan, Andrew , Jacobs, Paul , Hulshizer, Thomas C., Rossman, Phillip J. , Frick, Matthew A., Amrami, Kimberly K. , Felmlee, Joel P. , Jacobs, Paul S, Fagan, Andrew J

Medical Physics | December 10, 2020 | Volume: 48 | Issue: 2 | Pages: 781-790

10.1002/mp.14641 Get It

PurposeA 7T magnetic resonance thermometry (MRT) technique was developed to validate the conversion factor between the system‐measured transmitted radiofrequency (RF) power into a home‐built RF wrist coil with the system‐predicted SAR value. The conversion factor for a new RF coil developed for ultra high magnetic field MRI systems is used to ensure that regulatory limits on RF energy deposition in tissue, specifically the local 10g‐averaged specific absorption rate (SAR10g), are not exceeded. MRT can be used to validate this factor by ensuring that MRT‐measured SAR values do not exceed those predicted by the system.MethodsA 14‐cm diameter high‐pass birdcage RF coil was built to image the wrist at 7T. A high spatial and temporal resolution dual‐echo gradient echo MRT technique, incorporating quasi‐simultaneous RF‐induced heating and temperature change measurements using the proton resonance frequency method, was developed. The technique allowed for high‐temperature resolution measurements (~±0.1°C) to be performed every 20 s over a 4‐min heating period, with high spatial resolution (2.56 mm3 voxel size) and avoiding phase discontinuities arising from severe magnetic susceptibility‐induced B0 inhomogeneities. Magnetic resonance thermometry was performed on a phantom made from polyvinylpyrrolidone to mimic the dielectric properties of muscle tissue at 297.2 MHz. Temperature changes measured with MRT and four fiber optic temperature sensors embedded in the phantom were compared. Electromagnetic simulations of the coil and phantom were developed and validated via comparison of simulated and measured B1+ maps in the phantom. The position of maximum SAR within the coil was determined from simulations, and MRT was performed within a wrist‐sized piece of meat positioned at that SAR hotspot location. MRT‐measured and system‐predicted SAR values for the phantom and meat were compared.ResultsTemperature change measurements from MRT matched closely to those from the fiber optic temperature sensors. The simulations were validated via close correlation between the simulated and MRT‐measured B1+ and SAR maps. Using a coil conversion factor of 2 kg−1, MRT‐measured point‐SAR values did not exceed the system‐predicted SAR10g in either the uniform phantom or in the piece of meat mimicking the wrist located at the SAR hotspot location.ConclusionsA highly accurate MRT technique with high spatial and temporal resolution was developed. This technique can be used to ensure that system‐predicted SAR values are not exceeded in practice, thereby providing independent validation of SAR levels delivered by a newly built RF wrist coil. The MRT technique is readily generalizable to perform safety evaluations for other RF coils at 7T.