Reply to “Letter to Editor by Dr. Steckner Regarding ‘Induction of Extremely Severe Nausea via Vestibular Activation on a 7 Tesla MRI Scanner’ by Fagan et al.”
Extremely severe nausea was experienced by four subjects positioned prone on a 7T scanner table with their arm extended overhead for a wrist examination and their head positioned approximately 10–20 cm above the magnet's central axis. Movement through the large static and spatial field gradients of current 7T MRI scanner magnets typically causes mild vestibular activation which is well tolerated by most individuals. However, when positioned off‐axis, the head moves through regions of even larger and more rapidly changing magnetic fields which in the current study were sufficient to induce the extremely severe nausea. Ensuring the head remains on‐axis mitigates this effect.
The effect of frequency (64–498 MHz) on specific absorption rate adjacent to metallic orthopedic screws in MRI: A numerical simulation study
AbstractBackgroundThe imaging of patients with implanted electrically‐conductive devices via magnetic resonance imaging at ultra‐high fields is hampered by uncertainties relating to the potential for inducing tissue heating adjacent to the implant due to coupling of energy from the incident electromagnetic field into the implant. Existing data in the peer‐reviewed literature of comparisons across field strengths of tissue heating and its surrogate, the specific absorption rate (SAR), is scarce and contradictory, leading to further doubts pertaining to the safety of imaging patients with such devices.PurposeThe radiofrequency‐induced SAR adjacent to orthopedic screws of varying length and at frequencies of 64 to 498 MHz was investigated via full‐wave electromagnetic simulations, to provide an accurate comparison of SAR across MRI field strengths.MethodsDipole antennas were used for RF transmission to achieve a uniform electric field tangential to the screws located 120 mm above the antenna midpoints, embedded in a bone‐mimicking material. The input power to the antennas was constrained to achieve the following targets without the screw present: (i) E = 100 V/m, (ii) B1+ = 2 μT, and (iii) global‐average‐SAR = 3.2 W/kg. Simulations were performed with a spatial resolution of 0.2 mm in the volume surrounding the screws, resulting in 76–137 MCells, noting the maximum 1 g‐averaged SAR value in each case. Simulations were repeated at 128 and 297 MHz for screws embedded in muscle tissue.ResultsThe peak SAR, occurring at the resonant screw length, substantially increased as the frequency decreased when the input power to the dipole antenna was constrained to achieve constant electric field in background tissue at the screws’ locations. A similar pattern was observed when constraining input power to achieve constant B1+ and global‐average‐SAR. The dielectric properties of the tissue in which the screws were embedded dominated the SAR comparisons between 297 and 128 MHz.ConclusionsThe study design allowed for a direct comparison to be performed of SAR across frequencies and implant lengths without the confounding effect of variable incident electric field. Lower frequencies produced substantially larger SAR values for implants approaching the resonant length for the worst‐case uniform incident electric field along the screws’ length. The data may inform risk‐benefit assessments for imaging patients with orthopedic implants at the new clinical field strength of 7 Tesla.
No Increased Mercury Release from Dental Restorations at 1.5T, 3T, or 7T MRI
AbstractPurposeDental amalgam contains mercury and is commonly used in dental restorations. The impact of MRI on mercury excretion from dental amalgam is not well understood across clinical field strengths, especially 7T. We investigated the effects of MRI exposure on mercury excretion using fresh, lab‐created dental amalgam restorations and in extracted teeth with old, pre‐existing restorations.MethodsDonated, unfilled human teeth (n = 120) were restored with amalgam before being stored in saline, artificial saliva, or a dry box prior to MRI scanning. The teeth were placed in individual tubes of fresh artificial saliva and scanned at 1.5T, 3T, or 7T or left unscanned as controls. Mercury concentrations were measured 24–30 h later. Donated teeth with pre‐existing restorations (n = 40) were stored in artificial saliva, scanned at 7T or left unscanned as controls, and mercury concentration tested.ResultsFor teeth extracted and restored in a laboratory, no significant difference was found (F = 2.42, P = 0.072) between mean mercury concentrations of unscanned teeth (13.72 μg/L) and teeth scanned at 1.5T (10.88 μg/L), 3T (12.65 μg/L), or 7T (8.88 μg/L). For teeth extracted with previously placed restorations, no significant difference (P = 0.288) was found between unscanned controls (4.28 μg/L) and teeth scanned at 7T (6.63 μg/L).ConclusionMRI of dental amalgam does not significantly increase mercury excretion at 1.5T, 3T, or 7T compared to unscanned teeth. This holds true for controlled laboratory restorations as well as for those placed and lived with prior to extraction and scanning, demonstrating no added risk to the clinical patient or research subject.
Development and Evaluation of a Multifrequency Ultrafast Doppler Spectral Analysis (MFUDSA) Algorithm for Wall Shear Stress Measurement: A Simulation and In Vitro Study
Cardiovascular pathology is the leading cause of death and disability in the Western world, and current diagnostic testing usually evaluates the anatomy of the vessel to determine if the vessel contains blockages and plaques. However, there is a growing school of thought that other measures, such as wall shear stress, provide more useful information for earlier diagnosis and prediction of atherosclerotic related disease compared to pulsed-wave Doppler ultrasound, magnetic resonance angiography, or computed tomography angiography. A novel algorithm for quantifying wall shear stress (WSS) in atherosclerotic plaque using diagnostic ultrasound imaging, called Multifrequency ultrafast Doppler spectral analysis (MFUDSA), is presented. The development of this algorithm is presented, in addition to its optimisation using simulation studies and in-vitro experiments with flow phantoms approximating the early stages of cardiovascular disease. The presented algorithm is compared with commonly used WSS assessment methods, such as standard PW Doppler, Ultrafast Doppler, and Parabolic Doppler, as well as plane-wave Doppler. Compared to an equivalent processing architecture with one-dimensional Fourier analysis, the MFUDSA algorithm provided an increase in signal-to-noise ratio (SNR) by a factor of 4–8 and an increase in velocity resolution by a factor of 1.10–1.35. The results indicated that MFUDSA outperformed the others, with significant differences detected between the typical WSS values of moderate disease progression (p = 0.003) and severe disease progression (p = 0.001). The algorithm demonstrated an improved performance for the assessment of WSS and has potential to provide an earlier diagnosis of cardiovascular disease than current techniques allow.
Minimizing magnetic resonance image geometric distortion at 7 Tesla for frameless presurgical planning using skin‐adhered fiducials
AbstractBackground7T MRI offers significant benefits to spatial and contrast resolution compared to lower field strengths. This superior image quality can help better delineate targets in stereotactic neurosurgical procedures; however, the potential for increased geometric distortions at 7T has impaired its widespread use for these applications. Image geometric distortions can be due to distortions of B0 arising from tissue magnetic susceptibility effects or inherent field inhomogeneities, and nonlinearity of the magnetic field gradients.PurposeThe purpose of this study was to investigate the use of 7T MRI for neurosurgical frameless stereotactic navigation procedures. Image geometric distortions at the skin surface in 7T images were minimized and compared to results from clinical 3T frameless imaging protocols.MethodsA 3D‐printed grid phantom filled with oil was designed to perform a fine calibration of the 7T imaging gradients, and an oil‐filled head phantom with internal targets was used to determine ground truth (from computed tomography [CT]) positioning errors. Three volunteers and the head phantom were imaged consecutively at 3T and 7T. Ten skin‐adhesive fiducial markers were placed on each subject's exposed skin surface at standard clinical placement locations for frameless procedures. Imaging sequences included MPRAGE (three bandwidths at 7T: 400, 690, and 1020 Hz/pixel, and one at 3T: 400 Hz/pixel), T2 SPACE, and T2 SPACE FLAIR acquisitions. An additional GRE field map was acquired on both scanners using a multi‐echo GRE sequence. Custom Matlab code was used to perform additional distortion correction of the images using the unwrapped field maps. Fiducial localization was performed with 3D Slicer, with absolute fiducial positioning errors determined in phantom experiments following rigid registration to the CT images. For human experiments, 3T and 7T images were registered and relative differences in fiducial locations were compared using two‐tailed paired t‐tests.ResultsPhantom measurements at 7T yielded gradient distance scaling errors of 1.1%, 2.2%, and 1.0% along the x‐, y‐, and z‐axes, respectively. These system miscalibrations were traced back to phantom manufacturing deviations in the sphericity of the vendor's gradient calibration phantom. Correction factors along each gradient axis were applied, and afterward, geometric distortions of less than 1 mm were obtained in the 7T MR head phantom images for the 1020 Hz/pixel bandwidth MPRAGE sequence. For the human subjects, four fiducial locations were excluded from the analysis due to patient positioning differences. Differences between 3T and 7T MPRAGE with low/medium/high bandwidth were 2.2 /2.6/2.3 mm, respectively, before the correction, reducing to 1.6/1.3/1.0 mm after the correction (p < 0.001). T2 SPACE and T2 SPACE FLAIR yielded a similar pattern when the correction was applied, decreasing from 2.1 to 0.8 mm, and 2.6 to 1.0 mm, respectively.Conclusions7T MRI can be used to perform frameless presurgical planning with skin‐adhesive fiducials. Geometric distortions can be reduced to a clinically relevant level (errors < ∼1 mm) with no significant susceptibility‐related distortions, by using high receiver bandwidth, ensuring gradients are properly calibrated, and placing skin fiducials in areas where distortions from patient positioning are minimal.
7T MR Thermometry technique for validation of system‐predicted SAR with a home‐built radiofrequency wrist coil
PurposeA 7T magnetic resonance thermometry (MRT) technique was developed to validate the conversion factor between the system‐measured transmitted radiofrequency (RF) power into a home‐built RF wrist coil with the system‐predicted SAR value. The conversion factor for a new RF coil developed for ultra high magnetic field MRI systems is used to ensure that regulatory limits on RF energy deposition in tissue, specifically the local 10g‐averaged specific absorption rate (SAR10g), are not exceeded. MRT can be used to validate this factor by ensuring that MRT‐measured SAR values do not exceed those predicted by the system.MethodsA 14‐cm diameter high‐pass birdcage RF coil was built to image the wrist at 7T. A high spatial and temporal resolution dual‐echo gradient echo MRT technique, incorporating quasi‐simultaneous RF‐induced heating and temperature change measurements using the proton resonance frequency method, was developed. The technique allowed for high‐temperature resolution measurements (~±0.1°C) to be performed every 20 s over a 4‐min heating period, with high spatial resolution (2.56 mm3 voxel size) and avoiding phase discontinuities arising from severe magnetic susceptibility‐induced B0 inhomogeneities. Magnetic resonance thermometry was performed on a phantom made from polyvinylpyrrolidone to mimic the dielectric properties of muscle tissue at 297.2 MHz. Temperature changes measured with MRT and four fiber optic temperature sensors embedded in the phantom were compared. Electromagnetic simulations of the coil and phantom were developed and validated via comparison of simulated and measured B1+ maps in the phantom. The position of maximum SAR within the coil was determined from simulations, and MRT was performed within a wrist‐sized piece of meat positioned at that SAR hotspot location. MRT‐measured and system‐predicted SAR values for the phantom and meat were compared.ResultsTemperature change measurements from MRT matched closely to those from the fiber optic temperature sensors. The simulations were validated via close correlation between the simulated and MRT‐measured B1+ and SAR maps. Using a coil conversion factor of 2 kg−1, MRT‐measured point‐SAR values did not exceed the system‐predicted SAR10g in either the uniform phantom or in the piece of meat mimicking the wrist located at the SAR hotspot location.ConclusionsA highly accurate MRT technique with high spatial and temporal resolution was developed. This technique can be used to ensure that system‐predicted SAR values are not exceeded in practice, thereby providing independent validation of SAR levels delivered by a newly built RF wrist coil. The MRT technique is readily generalizable to perform safety evaluations for other RF coils at 7T.
Magnetic resonance imaging and spectroscopy (MRI/MRS) at 7T represents an exciting advance in MR technology, with intriguing possibilities to enhance image spatial, spectral, and contrast resolution. To ensure the safe use of this technology while still harnessing its potential, clinical staff and researchers need to be cognizant of some safety concerns arising from the increased magnetic field strength and higher Larmor frequency. The higher static magnetic fields give rise to enhanced transient bioeffects and an increased risk of adverse incidents related to electrically conductive implants. Many technical challenges remain and the continuing rapid pace of development of 7T MRI/MRS is likely to present further challenges to ensuring safety of this technology in the years ahead. The recent regulatory clearance for clinical diagnostic imaging at 7T will likely increase the installed base of 7T systems, particularly in hospital environments with little prior ultrahigh‐field MR experience. Informed risk/benefit analyses will be required, particularly where implant manufacturer‐published 7T safety guidelines for implants are unavailable. On behalf of the International Society for Magnetic Resonance in Medicine, the aim of this article is to provide a reference document to assist institutions developing local institutional policies and procedures that are specific to the safe operation of 7T MRI/MRS. Details of current 7T technology and the physics underpinning its functionality are reviewed, with the aim of supporting efforts to expand the use of 7T MRI/MRS in both research and clinical environments. Current gaps in knowledge are also identified, where additional research and development are required. Level of Evidence 5 Technical Efficacy 2 J. MAGN. RESON. IMAGING 2021;53:333–346.
Multimodal Breast Phantoms for Microwave, Ultrasound, Mammography, Magnetic Resonance and Computed Tomography Imaging
The aim of this work was to develop multimodal anthropomorphic breast phantoms suitable for evaluating the imaging performance of a recently-introduced Microwave Imaging (MWI) technique in comparison to the established diagnostic imaging modalities of Magnetic Resonance Imaging (MRI), Ultrasound (US), mammography and Computed Tomography (CT). MWI is an emerging technique with significant potential to supplement established imaging techniques to improve diagnostic confidence for breast cancer detection. To date, numerical simulations have been used to assess the different MWI scanning and image reconstruction algorithms in current use, while only a few clinical trials have been conducted. To bridge the gap between the numerical simulation environment and a more realistic diagnostic scenario, anthropomorphic phantoms which mimic breast tissues in terms of their heterogeneity, anatomy, morphology, and mechanical and dielectric characteristics, may be used. Key in this regard is achieving realism in the imaging appearance of the different healthy and pathologic tissue types for each of the modalities, taking into consideration the differing imaging and contrast mechanisms for each modality. Suitable phantoms can thus be used by radiologists to correlate image findings between the emerging MWI technique and the more familiar images generated by the conventional modalities. Two phantoms were developed in this study, representing difficult-to-image and easy-to-image patients: the former contained a complex boundary between the mammary fat and fibroglandular tissues, extracted from real patient MRI datasets, while the latter contained a simpler and less morphologically accurate interface. Both phantoms were otherwise identical, with tissue-mimicking materials (TMMs) developed to mimic skin, subcutaneous fat, fibroglandular tissue, tumor and pectoral muscle. The phantoms’ construction used non-toxic materials, and they were inexpensive and relatively easy to manufacture. Both phantoms were scanned using conventional modalities (MRI, US, mammography and CT) and a recently introduced MWI radar detection procedure called in-coherent Multiple Signal Classification (I-MUSIC). Clinically realistic artifact-free images of the anthropomorphic breast phantoms were obtained using the conventional imaging techniques as well as the emerging technique of MWI.