ObjectivesTo evaluate the timing and distribution of first renal cell carcinoma metastasis after nephrectomy stratified by nodal status.MethodsWe evaluated patients treated with nephrectomy for sporadic, unilateral renal cell carcinoma between 1970 and 2011 who subsequently developed distant metastasis to three or fewer sites. Site‐specific metastases‐free 2‐year survival rates were estimated using the Kaplan–Meier method. Associations of nodal status with time to metastasis were evaluated using multivariable Cox regression models.ResultsA total of 1049 patients met the inclusion criteria (135 pN1, 914 pN0/x patients). The median time to identification of first distant metastasis for pN1 patients was 0.4 years (interquartile range 0.2–1.1 years) versus 2.2 years (interquartile range 0.6–6.0 years) in pN0/x patients. The most common site of metastasis was to the lung, but this occurred earlier in pN1 patients (median 0.3 years vs 2.0 years). pN1 was associated with significantly lower site‐specific 2‐year metastases‐free survival when compared with pN0/x for lung (37% vs 70%, P < 0.001), bone (63% vs 87%, P < 0.001), non‐regional lymph nodes (60% vs 96%, P < 0.001) and liver metastases (79% vs 91%, P < 0.001). On multivariable analysis, pN1 status remained significantly associated with lung, bone, and non‐regional lymph node (all P < 0.001) metastases, but it was no longer associated with liver metastases (P = 0.3).ConclusionspN1 nodal status in M0 patients treated with nephrectomy for renal cell carcinoma is associated with more frequent early metastasis to sites conferring poor prognosis when compared with pN0/x. Our findings highlight the importance of rigorous, early surveillance though the multimodal use of a comprehensive history, physical, laboratory and radiological studies, as outlined in societal guidelines.
Modified acquisition strategy for reduced motion artifact in super resolution FSE multislice MRI: Application to prostate
PurposeTo reduce slice‐to‐slice motion effects in multislice ‐weighted fast‐spin‐echo ( FSE) imaging, manifest as “scalloping” in reformats, by modification of the acquisition strategy and to show applicability in prostate MRI.Methods FSE images of contiguous or overlapping slices are typically acquired using multiple passes in which each pass is comprised of multiple slices with slice‐to‐slice gaps. Combination of slices from all passes provides the desired sampling. For enhancement of through‐plane resolution with super resolution or for reformatting into other orientations, subtle ≈1 mm motion between passes can cause objectionable “scalloping” artifact. Here we address this by subdivision of each pass into multiple segments. Interleaving of segments from the multiple passes causes all slices to be acquired over substantially the same time, reducing pass‐to‐pass motion effects. This was implemented in acquiring 78 overlapped FSE axial slices and studied in phantoms and in 14 prostate MRI patients. Super‐resolution axial images and sagittal reformats from the original and new segmented acquisitions were evaluated by 3 uroradiologists.ResultsFor all criteria of sagittal reformats, the segmented acquisition was statistically superior to the original. For all sharpness criteria of axial images, although the trend preferred the original acquisition, the difference was not significant. For artifact in axial images, the segmented acquisition was significantly superior.ConclusionsFor prostate MRI the new segmented acquisition significantly reduces the scalloping motion artifact that can be present in reformats due to long time lags between the acquisition of adjacent or overlapped slices while retaining image sharpness in the acquired axial slices.
Use of kZ‐space for high through‐plane resolution in multislice MRI: Application to prostate
PurposeThe goal of this work is to demonstrate 1 mm through‐plane resolution in multislice T2SE MRI using k‐space processing of overlapping slices and show applicability in prostate MRI.MethodsMultiple overlapped slices are acquired and Fourier transformed in the slice‐select direction. The slice profile is incorporated into a Tikhonov‐regularized reconstruction. Through‐plane resolution is tested in a resolution phantom. An anthropomorphic prostate phantom is used to study the SNR, and results are compared with theoretical prediction. The proposed method is tested in 16 patients indicated for clinical prostate MRI who gave written informed consent as overseen by our IRB. The “proposed” vs. “reference” multislice images are compared using multiple evaluation criteria for through‐plane resolution.ResultsThe modulation transfer function (MTF) plots of the resolution phantom show good modulation at frequency 0.5 lp/mm, demonstrating 1 mm through‐plane resolution restoration. The SNR measurements experimentally match the theoretically predicted values. The radiological evaluation shows that the proposed method is superior to the reference method for five criteria of sharpness but inferior with respect to artifacts.ConclusionsIn conjunction with overlapped slices a k‐space‐based reconstruction approach can be used to improve through‐plane resolution in multislice T2SE MRI. 1 mm resolution is demonstrated from 3.2 mm thick slices. The in vivo results from prostate MRI show improved sharpness when compared to the standard multislice method.
Safety and Image Quality of 1.5-T Endorectal Coil Multiparametric MRI of the Prostate or Prostatectomy Fossa for Patients With Pacemaker or Implantable Cardioverter-Defibrillator
Automatic total kidney volume measurement on follow-up magnetic resonance images to facilitate monitoring of autosomal dominant polycystic kidney disease progression
Abstract Background Renal imaging examinations provide high-resolution information about the anatomic structure of the kidneys and are used to measure total kidney volume (TKV) in autosomal dominant polycystic kidney disease (ADPKD) patients. TKV has become the gold-standard image biomarker for ADPKD progression at early stages of the disease and is used in clinical trials to characterize treatment efficacy. Automated methods to segment the kidneys and measure TKV are desirable because of the long time requirement for manual approaches such as stereology or planimetry tracings. However, ADPKD kidney segmentation is complicated by a number of factors, including irregular kidney shapes and variable tissue signal at the kidney borders. Methods We describe an image processing approach that overcomes these problems by using a baseline segmentation initialization to provide automatic segmentation of follow-up scans obtained years apart. We validated our approach using 20 patients with complete baseline and follow-up T1-weighted magnetic resonance images. Both manual tracing and stereology were used to calculate TKV, with two observers performing manual tracings and one observer performing repeat tracings. Linear correlation and Bland–Altman analysis were performed to compare the different approaches. Results Our automated approach measured TKV at a level of accuracy (mean difference ± standard error = 0.99 ± 0.79%) on par with both intraobserver (0.77 ± 0.46%) and interobserver variability (1.34 ± 0.70%) of manual tracings. All approaches had excellent agreement and compared favorably with ground-truth manual tracing with interobserver, stereological and automated approaches having 95% confidence intervals ∼±100 mL. Conclusions Our method enables fast, cost-effective and reproducible quantification of ADPKD progression that will facilitate and lower the costs of clinical trials in ADPKD and other disorders requiring accurate, longitudinal kidney quantification. In addition, it will hasten the routine use of TKV as a prognostic biomarker in ADPKD.
Utilizing magnetization transfer imaging to investigate tissue remodeling in a murine model of autosomal dominant polycystic kidney disease