Back to Authors

King, Bernard F.

Mayo Clinic

Mayo Clinic

Citations 21

Timing and distribution of early renal cell carcinoma recurrences stratified by pathological nodal status in M0 patients at the time of nephrectomy
Yang, David Y. , Potretzke, Theodora A. , Miest, Tanner, Bhindi, Bimal , Lohse, Christine M. , Cheville, John C. , King, Bernard F., Boorjian, Stephen A. , Leibovich, Bradley C. , Thompson, R. Houston, Potretzke, Aaron M. , Miest, Tanner S, Yang Md, David

International Journal of Urology | May 19, 2020 | Volume: 27 | Issue: 7 | Pages: 618-622

10.1111/iju.14261 Get It

ObjectivesTo evaluate the timing and distribution of first renal cell carcinoma metastasis after nephrectomy stratified by nodal status.MethodsWe evaluated patients treated with nephrectomy for sporadic, unilateral renal cell carcinoma between 1970 and 2011 who subsequently developed distant metastasis to three or fewer sites. Site‐specific metastases‐free 2‐year survival rates were estimated using the Kaplan–Meier method. Associations of nodal status with time to metastasis were evaluated using multivariable Cox regression models.ResultsA total of 1049 patients met the inclusion criteria (135 pN1, 914 pN0/x patients). The median time to identification of first distant metastasis for pN1 patients was 0.4 years (interquartile range 0.2–1.1 years) versus 2.2 years (interquartile range 0.6–6.0 years) in pN0/x patients. The most common site of metastasis was to the lung, but this occurred earlier in pN1 patients (median 0.3 years vs 2.0 years). pN1 was associated with significantly lower site‐specific 2‐year metastases‐free survival when compared with pN0/x for lung (37% vs 70%, P < 0.001), bone (63% vs 87%, P < 0.001), non‐regional lymph nodes (60% vs 96%, P < 0.001) and liver metastases (79% vs 91%, P < 0.001). On multivariable analysis, pN1 status remained significantly associated with lung, bone, and non‐regional lymph node (all P < 0.001) metastases, but it was no longer associated with liver metastases (P = 0.3).ConclusionspN1 nodal status in M0 patients treated with nephrectomy for renal cell carcinoma is associated with more frequent early metastasis to sites conferring poor prognosis when compared with pN0/x. Our findings highlight the importance of rigorous, early surveillance though the multimodal use of a comprehensive history, physical, laboratory and radiological studies, as outlined in societal guidelines.
Modified acquisition strategy for reduced motion artifact in super resolution FSE multislice MRI: Application to prostate
Kargar, Soudabeh , Borisch, Eric A. , Froemming, Adam T. , Grimm, Roger C., King, Bernard F., Stinson, Eric G. , Riederer, Stephen J. , Kawashima, Akira

Magnetic Resonance in Medicine | May 18, 2020 | Volume: 84 | Issue: 5 | Pages: 2537-2550

10.1002/mrm.28315 Get It

PurposeTo reduce slice‐to‐slice motion effects in multislice ‐weighted fast‐spin‐echo ( FSE) imaging, manifest as “scalloping” in reformats, by modification of the acquisition strategy and to show applicability in prostate MRI.Methods FSE images of contiguous or overlapping slices are typically acquired using multiple passes in which each pass is comprised of multiple slices with slice‐to‐slice gaps. Combination of slices from all passes provides the desired sampling. For enhancement of through‐plane resolution with super resolution or for reformatting into other orientations, subtle ≈1 mm motion between passes can cause objectionable “scalloping” artifact. Here we address this by subdivision of each pass into multiple segments. Interleaving of segments from the multiple passes causes all slices to be acquired over substantially the same time, reducing pass‐to‐pass motion effects. This was implemented in acquiring 78 overlapped FSE axial slices and studied in phantoms and in 14 prostate MRI patients. Super‐resolution axial images and sagittal reformats from the original and new segmented acquisitions were evaluated by 3 uroradiologists.ResultsFor all criteria of sagittal reformats, the segmented acquisition was statistically superior to the original. For all sharpness criteria of axial images, although the trend preferred the original acquisition, the difference was not significant. For artifact in axial images, the segmented acquisition was significantly superior.ConclusionsFor prostate MRI the new segmented acquisition significantly reduces the scalloping motion artifact that can be present in reformats due to long time lags between the acquisition of adjacent or overlapped slices while retaining image sharpness in the acquired axial slices.
Use of kZ‐space for high through‐plane resolution in multislice MRI: Application to prostate
Froemming, Adam T. , Grimm, Roger C., King, Bernard F., Stinson, Eric G. , Riederer, Stephen J. , Kargar, Soudabeh , Borisch, Eric A. , Kawashima, Akira

Magnetic Resonance in Medicine | March 7, 2019 | Volume: 81 | Issue: 6 | Pages: 3691-3704

10.1002/mrm.27691 Get It

PurposeThe goal of this work is to demonstrate 1 mm through‐plane resolution in multislice T2SE MRI using k‐space processing of overlapping slices and show applicability in prostate MRI.MethodsMultiple overlapped slices are acquired and Fourier transformed in the slice‐select direction. The slice profile is incorporated into a Tikhonov‐regularized reconstruction. Through‐plane resolution is tested in a resolution phantom. An anthropomorphic prostate phantom is used to study the SNR, and results are compared with theoretical prediction. The proposed method is tested in 16 patients indicated for clinical prostate MRI who gave written informed consent as overseen by our IRB. The “proposed” vs. “reference” multislice images are compared using multiple evaluation criteria for through‐plane resolution.ResultsThe modulation transfer function (MTF) plots of the resolution phantom show good modulation at frequency 0.5 lp/mm, demonstrating 1 mm through‐plane resolution restoration. The SNR measurements experimentally match the theoretically predicted values. The radiological evaluation shows that the proposed method is superior to the reference method for five criteria of sharpness but inferior with respect to artifacts.ConclusionsIn conjunction with overlapped slices a k‐space‐based reconstruction approach can be used to improve through‐plane resolution in multislice T2SE MRI. 1 mm resolution is demonstrated from 3.2 mm thick slices. The in vivo results from prostate MRI show improved sharpness when compared to the standard multislice method.
Safety and Image Quality of 1.5-T Endorectal Coil Multiparametric MRI of the Prostate or Prostatectomy Fossa for Patients With Pacemaker or Implantable Cardioverter-Defibrillator
Tanaka, Takashi , Froemming, Adam T. , Panda, Anshuman , Edmonson, Heidi A. , Pooley, Robert A. , Carter, Rickey E. , King, Bernard F., Carter, Rickey E , Kawashima, Akira

American Journal of Roentgenology | January 30, 2019 | Volume: 212 | Issue: 4 | Pages: 815-822

10.2214/ajr.18.20266 Get It

Guest Editorial: Discovery and Artificial Intelligence
King, Bernard F.

American Journal of Roentgenology | November 21, 2017 | Volume: 209 | Issue: 6 | Pages: 1189-1190

10.2214/ajr.17.19178 Get It

Splenosis Presenting as a Left Renal Mass Indistinguishable from Renal Cell Carcinoma
Bock, David B., King, Bernard F., Hezmall, H. Pat, Oesterling, Joseph E.

Journal of Urology | June 29, 2017 | Volume: 146 | Issue: 1 | Pages: 152-154

10.1016/s0022-5347(17)37737-6 Get It

Use of Personalized Printed 3-Dimensional Kidney Models for Simulation before Nephron Sparing Surgery: Methodology and Examples from a Case Series
Gershman, Boris , Matsumoto, Jane M., King, Bernard F., Leibovich, Bradley C. , Psutka, Sarah P. , Kawashima, Akira , Morris, Jonathan M.

Urology Practice | December 21, 2015 | Volume: 3 | Issue: 2 | Pages: 124-133

10.1016/j.urpr.2015.05.008 Get It

Automatic total kidney volume measurement on follow-up magnetic resonance images to facilitate monitoring of autosomal dominant polycystic kidney disease progression
Kline, Timothy L. , Korfiatis, Panagiotis , Edwards, Marie E., Warner, Joshua , Irazabal, María V. , King, Bernard F., Torres, Vicente E. , Warner, Joshua D, Erickson, Bradley J. , Torres, Vicente E , Irazabal, Maria V

Nephrology Dialysis Transplantation | September 11, 2015 | Volume: 31 | Issue: 2 | Pages: 241-248

10.1093/ndt/gfv314 Get It

Abstract Background Renal imaging examinations provide high-resolution information about the anatomic structure of the kidneys and are used to measure total kidney volume (TKV) in autosomal dominant polycystic kidney disease (ADPKD) patients. TKV has become the gold-standard image biomarker for ADPKD progression at early stages of the disease and is used in clinical trials to characterize treatment efficacy. Automated methods to segment the kidneys and measure TKV are desirable because of the long time requirement for manual approaches such as stereology or planimetry tracings. However, ADPKD kidney segmentation is complicated by a number of factors, including irregular kidney shapes and variable tissue signal at the kidney borders. Methods We describe an image processing approach that overcomes these problems by using a baseline segmentation initialization to provide automatic segmentation of follow-up scans obtained years apart. We validated our approach using 20 patients with complete baseline and follow-up T1-weighted magnetic resonance images. Both manual tracing and stereology were used to calculate TKV, with two observers performing manual tracings and one observer performing repeat tracings. Linear correlation and Bland–Altman analysis were performed to compare the different approaches. Results Our automated approach measured TKV at a level of accuracy (mean difference ± standard error = 0.99 ± 0.79%) on par with both intraobserver (0.77 ± 0.46%) and interobserver variability (1.34 ± 0.70%) of manual tracings. All approaches had excellent agreement and compared favorably with ground-truth manual tracing with interobserver, stereological and automated approaches having 95% confidence intervals ∼±100 mL. Conclusions Our method enables fast, cost-effective and reproducible quantification of ADPKD progression that will facilitate and lower the costs of clinical trials in ADPKD and other disorders requiring accurate, longitudinal kidney quantification. In addition, it will hasten the routine use of TKV as a prognostic biomarker in ADPKD.
Utilizing magnetization transfer imaging to investigate tissue remodeling in a murine model of autosomal dominant polycystic kidney disease
Kline, Timothy L. , Irazabal, María V. , Ebrahimi, Behzad , Udoji, Kelly N., Warner, Joshua , Korfiatis, Panagiotis , Mishra, Prasanna K. , Venkatesh, Sudhakar K. , Lerman, Lilach O. , Harris, Peter C. , Torres, Vicente E. , King, Bernard F., Hopp, Katharina , Warner, Joshua D, Macura, Slobodan I, Macura, Slobodan , Erickson, Bradley J. , Harris, Peter C , Torres, Vicente E , Venkatesh, Sudhakar K , Irazabal, Maria V

Magnetic Resonance in Medicine | May 14, 2015 | Volume: 75 | Issue: 4 | Pages: 1466-1473

10.1002/mrm.25701 Get It

PurposeNoninvasive imaging techniques that quantify renal tissue composition are needed to more accurately ascertain prognosis and monitor disease progression in polycystic kidney disease (PKD). Given the success of magnetization transfer (MT) imaging to characterize various tissue remodeling pathologies, it was tested on a murine model of autosomal dominant PKD.MethodsC57Bl/6 Pkd1 R3277C mice at 9, 12, and 15 months were imaged with a 16.4T MR imaging system. Images were acquired without and with RF saturation in order to calculate MT ratio (MTR) maps. Following imaging, the mice were euthanized and kidney sections were analyzed for cystic and fibrotic indices, which were compared with statistical parameters of the MTR maps.ResultsThe MTR‐derived mean, median, 25th percentile, skewness, and kurtosis were all closely related to indices of renal pathology, including kidney weight/body weight, cystic index, and percent of remaining parenchyma. The correlation between MTR and histology‐derived cystic and fibrotic changes was R2 = 0.84 and R2 = 0.70, respectively.ConclusionMT imaging provides a new, noninvasive means of measuring tissue remodeling PKD changes and may be better suited for characterizing renal impairment compared with conventional MR techniques. Magn Reson Med 75:1466–1473, 2016. © 2015 The Authors. Magnetic Resonance in Medicine published by Wiley Periodicals, Inc. on behalf of International Society for Magnetic Resonance.
Chronic Perineal Pain Caused by Pudendal Nerve Entrapment: Anatomy and CT-Guided Perineural Injection Technique
Hough, David M., Wittenberg, Keith H., Pawlina, Wojciech, Maus, Timothy P. , King, Bernard F., Vrtiska, Terri J., Farrell, Michael A., Antolak, Stanley J.

American Journal of Roentgenology | February 28, 2013 | Volume: 181 | Issue: 2 | Pages: 561-567

10.2214/ajr.181.2.1810561 Get It